메뉴 건너뛰기




Volumn 51, Issue 6, 2010, Pages 3318-3326

Measurement of the time course of optical quality and visual deterioration during tear break-up

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CONTACT LENS; CONTRAST SENSITIVITY; CONTROLLED STUDY; EYE REFRACTION; EYELID REFLEX; FEMALE; FOURIER ANALYSIS; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; LACRIMATION; MALE; NORMAL HUMAN; OPTICAL QUALITY; PRIORITY JOURNAL; PUPIL; TEAR BREAK UP; VISUAL SYSTEM FUNCTION; VISUAL SYSTEM PARAMETERS; ABERROMETRY; COMPARATIVE STUDY; CORNEAL WAVEFRONT ABERRATION; DRY EYE; HYDROPHILIC CONTACT LENS; LACRIMAL FLUID; METABOLISM; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; TIME; VISUAL ACUITY; VISUAL DISORDER;

EID: 77953248132     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.09-4831     Document Type: Article
Times cited : (63)

References (55)
  • 1
    • 0032783962 scopus 로고    scopus 로고
    • Symptoms of ocular irritation in patients diagnosed with dry eye
    • Nichols KK, Begley CG, Caffery B, Jones LA. Symptoms of ocular irritation in patients diagnosed with dry eye. Optom Vis Sci. 1999; 76:838-844.
    • (1999) Optom Vis Sci , vol.76 , pp. 838-844
    • Nichols, K.K.1    Begley, C.G.2    Caffery, B.3    Jones, L.A.4
  • 2
    • 0034900593 scopus 로고    scopus 로고
    • Characterization of ocular surface symptoms from optometric practices in North America
    • Begley CG, Chalmers RL, Mitchell GL, et al. Characterization of ocular surface symptoms from optometric practices in North America. Cornea. 2001;20:610-618.
    • (2001) Cornea , vol.20 , pp. 610-618
    • Begley, C.G.1    Chalmers, R.L.2    Mitchell, G.L.3
  • 3
    • 68949097527 scopus 로고    scopus 로고
    • Corneal epithelial opacity in dysfunctional tear syndrome
    • Chen JJ, Rao K, Pflugfelder SC. Corneal epithelial opacity in dysfunctional tear syndrome. Am J Ophthalmol. 2009;148:376-382.
    • (2009) Am J Ophthalmol , vol.148 , pp. 376-382
    • Chen, J.J.1    Rao, K.2    Pflugfelder, S.C.3
  • 4
    • 35748970482 scopus 로고    scopus 로고
    • Measurement of ocular surface irritation on a linear interval scale with the ocular comfort index
    • Johnson ME, Murphy PJ. Measurement of ocular surface irritation on a linear interval scale with the ocular comfort index. Invest Ophthalmol Vis Sci. 2007;48:4451-4458.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 4451-4458
    • Johnson, M.E.1    Murphy, P.J.2
  • 5
    • 0037983882 scopus 로고    scopus 로고
    • Assessing the severity of keratitis sicca with videokeratoscopic indices
    • Sade de Paiva C, Lindsey JL, Pflugfelder SC. Assessing the severity of keratitis sicca with videokeratoscopic indices. Ophthalmology. 2003;110:1102-1109.
    • (2003) Ophthalmology , vol.110 , pp. 1102-1109
    • Sade de Paiva, C.1    Lindsey, J.L.2    Pflugfelder, S.C.3
  • 6
    • 34347243555 scopus 로고    scopus 로고
    • The definition and classification of dry eye disease: report of the Definition and Classification Subcommittee of the International Dry Eye WorkShop
    • The definition and classification of dry eye disease: report of the Definition and Classification Subcommittee of the International Dry Eye WorkShop. Ocul Surf. 2007;5:75-92.
    • (2007) Ocul Surf , vol.5 , pp. 75-92
  • 8
    • 34548025334 scopus 로고    scopus 로고
    • Role of the tear film in the optical quality of the human eye
    • Montes-Mico R. Role of the tear film in the optical quality of the human eye. J Cataract Refract Surg. 2007;33:1631-1635.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1631-1635
    • Montes-Mico, R.1
  • 9
    • 0036283656 scopus 로고    scopus 로고
    • Contact lens drying and visual performance: The vision cycle with contact lenses
    • Thai LC, Tomlinson A, Ridder WH. Contact lens drying and visual performance: the vision cycle with contact lenses. Optom Vis Sci. 2002;79:381-388.
    • (2002) Optom Vis Sci , vol.79 , pp. 381-388
    • Thai, L.C.1    Tomlinson, A.2    Ridder, W.H.3
  • 10
    • 0036143134 scopus 로고    scopus 로고
    • Impaired functional visual acuity of dry eye patients
    • Goto E, Yagi Y, Matsumoto Y, Tsubota K. Impaired functional visual acuity of dry eye patients. Am J Ophthalmol. 2002;133:181-186.
    • (2002) Am J Ophthalmol , vol.133 , pp. 181-186
    • Goto, E.1    Yagi, Y.2    Matsumoto, Y.3    Tsubota, K.4
  • 12
    • 34547489521 scopus 로고    scopus 로고
    • Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics
    • Hirohara Y, Mihashi T, Koh S, Ninomiya S, Maeda N, Fujikado T. Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics. Jpn J Ophthalmol. 2007;51: 258-264.
    • (2007) Jpn J Ophthalmol , vol.51 , pp. 258-264
    • Hirohara, Y.1    Mihashi, T.2    Koh, S.3    Ninomiya, S.4    Maeda, N.5    Fujikado, T.6
  • 13
    • 0037237880 scopus 로고    scopus 로고
    • Use of retroillumination to visualize optical aberrations caused by tear film break-up
    • Himebaugh NL, Wright AR, Bradley A, Begley CG, Thibos LN. Use of retroillumination to visualize optical aberrations caused by tear film break-up. Optom Vis Sci. 2003;80:69-78.
    • (2003) Optom Vis Sci , vol.80 , pp. 69-78
    • Himebaugh, N.L.1    Wright, A.R.2    Bradley, A.3    Begley, C.G.4    Thibos, L.N.5
  • 14
    • 67849111872 scopus 로고    scopus 로고
    • The effect of soft contact lens wear and time from blink on wavefront aberration measurement variation
    • Rae SM, Price HC. The effect of soft contact lens wear and time from blink on wavefront aberration measurement variation. Clin Exp Optom. 2009;92:274-282.
    • (2009) Clin Exp Optom , vol.92 , pp. 274-282
    • Rae, S.M.1    Price, H.C.2
  • 15
    • 41149179193 scopus 로고    scopus 로고
    • Effects of suppression of blinking on quality of vision in borderline cases of evaporative dry eye
    • Koh S, Maeda N, Hori Y, et al. Effects of suppression of blinking on quality of vision in borderline cases of evaporative dry eye. Cornea. 2008;27:275-278.
    • (2008) Cornea , vol.27 , pp. 275-278
    • Koh, S.1    Maeda, N.2    Hori, Y.3
  • 16
    • 0032776742 scopus 로고    scopus 로고
    • Clinical applications of the Shack-Hartmann aberrometer
    • Thibos LN, Hong X. Clinical applications of the Shack-Hartmann aberrometer. Optom Vis Sci. 1999;76:817-825.
    • (1999) Optom Vis Sci , vol.76 , pp. 817-825
    • Thibos, L.N.1    Hong, X.2
  • 17
    • 39549088565 scopus 로고    scopus 로고
    • Serial measurements of higher-order aberrations after blinking in patients with dry eye
    • Koh S, Maeda N, Hirohara Y, et al. Serial measurements of higher-order aberrations after blinking in patients with dry eye. Invest Ophthalmol Vis Sci. 2008;49:133-138.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 133-138
    • Koh, S.1    Maeda, N.2    Hirohara, Y.3
  • 18
    • 9144239521 scopus 로고    scopus 로고
    • Evaluation of the tear film stability after laser in situ keratomileusis using the tear film stability analysis system
    • Goto T, Zheng X, Klyce SD, et al. Evaluation of the tear film stability after laser in situ keratomileusis using the tear film stability analysis system. Am J Ophthalmol. 2004;137:116-120.
    • (2004) Am J Ophthalmol , vol.137 , pp. 116-120
    • Goto, T.1    Zheng, X.2    Klyce, S.D.3
  • 19
    • 0026601251 scopus 로고
    • The importance of the precorneal tear film for the quality of optical imaging
    • Rieger G. The importance of the precorneal tear film for the quality of optical imaging. Br J Ophthalmol. 1992;76:157-158.
    • (1992) Br J Ophthalmol , vol.76 , pp. 157-158
    • Rieger, G.1
  • 20
    • 0033504306 scopus 로고    scopus 로고
    • Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency
    • Liu Z, Pflugfelder SC. Corneal surface regularity and the effect of artificial tears in aqueous tear deficiency. Ophthalmology. 1999; 106:939-943.
    • (1999) Ophthalmology , vol.106 , pp. 939-943
    • Liu, Z.1    Pflugfelder, S.C.2
  • 21
    • 25644435752 scopus 로고    scopus 로고
    • Effect of artificial tears on visual performance in subjects with dry eye
    • Ridder WH 3rd, Tomlinson A, Paugh J. Effect of artificial tears on visual performance in subjects with dry eye. Optom Vis Sci. 2005; 82:835-842.
    • (2005) Optom Vis Sci , vol.82 , pp. 835-842
    • Ridder, W.H.1    Tomlinson, A.2    Paugh, J.3
  • 24
    • 0027229192 scopus 로고
    • Effects of target distance and pupil size on letter contrast sensitivity with simultaneous vision bifocal contact lenses
    • Bradley A, Abdul Rahman H, Soni PS, Zhang X. Effects of target distance and pupil size on letter contrast sensitivity with simultaneous vision bifocal contact lenses. Optom Vis Sci. 1993;70:476-481.
    • (1993) Optom Vis Sci , vol.70 , pp. 476-481
    • Bradley, A.1    Abdul Rahman, H.2    Soni, P.S.3    Zhang, X.4
  • 25
    • 25144509365 scopus 로고    scopus 로고
    • Zonal matrix iterative method for wavefront reconstruction from gradient measurements
    • Panagopoulou SI, Neal DR. Zonal matrix iterative method for wavefront reconstruction from gradient measurements. J Refract Surg. 2005;21:S563-569.
    • (2005) J Refract Surg , vol.21
    • Panagopoulou, S.I.1    Neal, D.R.2
  • 26
    • 0012631613 scopus 로고    scopus 로고
    • Assessment of optical quality
    • In: MacRae S, Krueger R, Applegate R, eds., Thorofare, NJ: Slack, Inc
    • Thibos LN, Applegate RA. Assessment of optical quality. In: MacRae S, Krueger R, Applegate R, eds. Customized Ablation and Super Vision. Thorofare, NJ: Slack, Inc.; 2001;67-78.
    • (2001) Customized Ablation and Super Vision , pp. 67-78
    • Thibos, L.N.1    Applegate, R.A.2
  • 27
    • 0031279198 scopus 로고    scopus 로고
    • Aberrations and retinal image quality of the normal human eye
    • Liang J, Williams DR. Aberrations and retinal image quality of the normal human eye. J Opt Soc Am A Opt Image Sci Vis. 1997;14: 2873-2883.
    • (1997) J Opt Soc Am a Opt Image Sci Vis , vol.14 , pp. 2873-2883
    • Liang, J.1    Williams, D.R.2
  • 30
    • 25144446164 scopus 로고    scopus 로고
    • Errors in Zernike transformations and non-modal reconstruction methods
    • Neal DR, Baer CD, Topa DM. Errors in Zernike transformations and non-modal reconstruction methods. J Refract Surg. 2005;21:S558-S562.
    • (2005) J Refract Surg , vol.21
    • Neal, D.R.1    Baer, C.D.2    Topa, D.M.3
  • 31
    • 3042586618 scopus 로고    scopus 로고
    • Accuracy and precision of objective refraction from wavefront aberrations
    • Thibos LN, Hong X, Bradley A, Applegate RA. Accuracy and precision of objective refraction from wavefront aberrations. J Vis. 2004;4:329-351.
    • (2004) J Vis , vol.4 , pp. 329-351
    • Thibos, L.N.1    Hong, X.2    Bradley, A.3    Applegate, R.A.4
  • 32
    • 0028302725 scopus 로고
    • The visual filter mediating letter identification
    • Solomon JA, Pelli DG. The visual filter mediating letter identification. Nature. 1994;369:395-397.
    • (1994) Nature , vol.369 , pp. 395-397
    • Solomon, J.A.1    Pelli, D.G.2
  • 35
    • 25144458387 scopus 로고    scopus 로고
    • Effect of tear film break-up on higher order aberrations of the anterior cornea in normal, dry, and post-LASIK eyes
    • Lin YY, Carrel H, Wang IJ, Lin PJ, Hu FR. Effect of tear film break-up on higher order aberrations of the anterior cornea in normal, dry, and post-LASIK eyes. J Refract Surg. 2005;21:S525-S529.
    • (2005) J Refract Surg , vol.21
    • Lin, Y.Y.1    Carrel, H.2    Wang, I.J.3    Lin, P.J.4    Hu, F.R.5
  • 36
    • 34548837746 scopus 로고    scopus 로고
    • Wavefront sensing and the dynamics of tear film
    • Koh S, Maeda N. Wavefront sensing and the dynamics of tear film. Cornea. 2007;26:S41-45.
    • (2007) Cornea , vol.26
    • Koh, S.1    Maeda, N.2
  • 37
    • 0026480331 scopus 로고
    • Short-term, low-contrast visual acuity reduction associated with in vivo contact lens drying
    • Timberlake GT, Doane MG, Bertera JH. Short-term, low-contrast visual acuity reduction associated with in vivo contact lens drying. Optom Vis Sci. 1992;69:755-760.
    • (1992) Optom Vis Sci , vol.69 , pp. 755-760
    • Timberlake, G.T.1    Doane, M.G.2    Bertera, J.H.3
  • 39
    • 0024846454 scopus 로고
    • Hydrogel lens wettability during overnight wear
    • Guillon M, Guillon JP. Hydrogel lens wettability during overnight wear. Ophthalmic Physiol Opt. 1989;9:355-359.
    • (1989) Ophthalmic Physiol Opt , vol.9 , pp. 355-359
    • Guillon, M.1    Guillon, J.P.2
  • 41
    • 0032997387 scopus 로고    scopus 로고
    • The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals
    • Acosta MC, Gallar J, Belmonte C. The influence of eye solutions on blinking and ocular comfort at rest and during work at video display terminals. Exp Eye Res. 1999;68:663-669.
    • (1999) Exp Eye Res , vol.68 , pp. 663-669
    • Acosta, M.C.1    Gallar, J.2    Belmonte, C.3
  • 43
    • 0034760169 scopus 로고    scopus 로고
    • Consideration of three types of spontaneous eyeblink activity in normal humans: During reading and video display terminal use, in primary gaze, and while in conversation
    • Doughty MJ. Consideration of three types of spontaneous eyeblink activity in normal humans: during reading and video display terminal use, in primary gaze, and while in conversation. Optom Vis Sci. 2001;78:712-725.
    • (2001) Optom Vis Sci , vol.78 , pp. 712-725
    • Doughty, M.J.1
  • 44
    • 33644847200 scopus 로고    scopus 로고
    • Tear breakup dynamics: A technique for quantifying tear film instability
    • Begley CG, Himebaugh N, Renner D, et al. Tear breakup dynamics: a technique for quantifying tear film instability. Optom Vis Sci. 2006;83:15-21.
    • (2006) Optom Vis Sci , vol.83 , pp. 15-21
    • Begley, C.G.1    Himebaugh, N.2    Renner, D.3
  • 46
    • 0037405481 scopus 로고    scopus 로고
    • A new method for tear film stability analysis using videokeratography
    • Goto T, Zheng X, Klyce SD, et al. A new method for tear film stability analysis using videokeratography. Am J Ophthalmol. 2003;135:607-612.
    • (2003) Am J Ophthalmol , vol.135 , pp. 607-612
    • Goto, T.1    Zheng, X.2    Klyce, S.D.3
  • 48
    • 68349086874 scopus 로고    scopus 로고
    • A link between tear instability and hyperosmolarity in dry eye
    • Liu H, Begley C, Chen M, et al. A link between tear instability and hyperosmolarity in dry eye. Invest Ophthalmol Vis Sci. 2009;50: 3671-3679.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 3671-3679
    • Liu, H.1    Begley, C.2    Chen, M.3
  • 49
    • 39049182137 scopus 로고    scopus 로고
    • Optical aberrations and visual disturbances associated with dry eye
    • Goto E, Ishida R, Kaido M, et al. Optical aberrations and visual disturbances associated with dry eye. Ocul Surf. 2006;4:207-213.
    • (2006) Ocul Surf , vol.4 , pp. 207-213
    • Goto, E.1    Ishida, R.2    Kaido, M.3
  • 50
    • 33845226832 scopus 로고    scopus 로고
    • Functional visual acuity in Stevens-Johnson syndrome
    • Kaido M, Dogru M, Yamada M, et al. Functional visual acuity in Stevens-Johnson syndrome. Am J Ophthalmol. 2006;142:917-922.
    • (2006) Am J Ophthalmol , vol.142 , pp. 917-922
    • Kaido, M.1    Dogru, M.2    Yamada, M.3
  • 51
    • 34548828263 scopus 로고    scopus 로고
    • Concept of functional visual acuity and its applications
    • Kaido M, Dogru M, Ishida R, Tsubota K. Concept of functional visual acuity and its applications. Cornea. 2007;26:S29-S35.
    • (2007) Cornea , vol.26
    • Kaido, M.1    Dogru, M.2    Ishida, R.3    Tsubota, K.4
  • 52
    • 0021993196 scopus 로고
    • A non-invasive instrument for clinical assessment of the pre-corneal tear film stability
    • Mengher LS, Bron AJ, Tonge SR, Gilbard DJ. A non-invasive instrument for clinical assessment of the pre-corneal tear film stability. Curr Eye Res. 1985;4:1-7.
    • (1985) Curr Eye Res , vol.4 , pp. 1-7
    • Mengher, L.S.1    Bron, A.J.2    Tonge, S.R.3    Gilbard, D.J.4
  • 53
    • 2442688230 scopus 로고    scopus 로고
    • A new noninvasive tear stability analysis system for the assessment of dry eyes
    • Kojima T, Ishida R, Dogru M, et al. A new noninvasive tear stability analysis system for the assessment of dry eyes. Invest Ophthalmol Vis Sci. 2004;45:1369-1374.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 1369-1374
    • Kojima, T.1    Ishida, R.2    Dogru, M.3
  • 54
    • 0034765815 scopus 로고    scopus 로고
    • Conditioning of hydrogel lenses by a multipurpose solution containing an ocular lubricant
    • Simmons PA, Donshik PC, Kelly WF, Vehige JG. Conditioning of hydrogel lenses by a multipurpose solution containing an ocular lubricant. CLAO J. 2001;27:192-194.
    • (2001) CLAO J , vol.27 , pp. 192-194
    • Simmons, P.A.1    Donshik, P.C.2    Kelly, W.F.3    Vehige, J.G.4
  • 55
    • 0024711249 scopus 로고
    • Clinical findings correlated with contact angles on rigid gas permeable contact lens surfaces in vivo
    • Bourassa S, Benjamin WJ. Clinical findings correlated with contact angles on rigid gas permeable contact lens surfaces in vivo. J Am Optom Assoc. 1989;60:584-590.
    • (1989) J Am Optom Assoc , vol.60 , pp. 584-590
    • Bourassa, S.1    Benjamin, W.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.