메뉴 건너뛰기




Volumn 5, Issue 4, 2010, Pages 247-253

Real-time elderly activity monitoring system based on a tri-axial accelerometer

Author keywords

Accelerometer; Activities of daily living; Algorithm; Elderly; Long term monitoring; Movement classification

Indexed keywords

ACCELERATION; AGE; AGED; ALGORITHM; AMBULATORY MONITORING; ARTICLE; BIOMECHANICS; BODY POSTURE; COMPUTER SYSTEM; DAILY LIFE ACTIVITY; EQUIPMENT DESIGN; FALLING; HUMAN; INSTRUMENTATION; LOCOMOTION; PHYSIOLOGY; REST; RISK FACTOR; SIGNAL PROCESSING; TIME; WALKING;

EID: 77953246589     PISSN: 17483107     EISSN: 17483115     Source Type: Journal    
DOI: 10.3109/17483101003718112     Document Type: Article
Times cited : (37)

References (21)
  • 1
    • 30744436064 scopus 로고    scopus 로고
    • Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. Information technology in biomedicine
    • Karantonis, DM, Narayanan MR, Mathie M, Lovell NH, Celler BG. Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring. Information technology in biomedicine. IEEE Trans 2006;10:156-167.
    • (2006) IEEE Trans , vol.10 , pp. 156-167
    • Karantonis, D.M.1    Narayanan, M.R.2    Mathie, M.3    Lovell, N.H.4    Celler, B.G.5
  • 2
    • 0028901147 scopus 로고
    • Reliability and validity of the Frail elderly functional assessment questionnaire
    • Gloth FM IIIrd, Walston J, Meyer J, Pearson J. Reliability and validity of the Frail elderly functional assessment questionnaire. Am J Phys Med Rehabil 1995;74:45-53.
    • (1995) Am J Phys Med Rehabil , vol.74 , pp. 45-53
    • Gloth III, F.M.1    Walston, J.2    Meyer, J.3    Pearson, J.4
  • 3
    • 0030924386 scopus 로고    scopus 로고
    • The arm motor ability test: Reliability, validity, and sensitivity to change of an instrument for assessing disabilities in activities of daily living
    • Kopp B, Kunkel A, Flor H, Platz T, Rose U, Mauritz KH, Gresser K, McCulloch KL, Taub E. The arm motor ability test: reliability, validity, and sensitivity to change of an instrument for assessing disabilities in activities of daily living. Arch Pyhs Med Rehabil 1997;78:615-620.
    • (1997) Arch Pyhs Med Rehabil , vol.78 , pp. 615-620
    • Kopp, B.1    Kunkel, A.2    Flor, H.3    Platz, T.4    Rose, U.5    Mauritz, K.H.6    Gresser, K.7    McCulloch, K.L.8    Taub, E.9
  • 4
    • 52649152417 scopus 로고    scopus 로고
    • Application of motion analysis system in pre-impact fall detection
    • Nyan MN, Tay FEH, Mah MZE. Application of motion analysis system in pre-impact fall detection. J Biomechanics 2008;41:2297-2304.
    • (2008) J Biomechanics , vol.41 , pp. 2297-2304
    • Nyan, M.N.1    Tay, F.E.H.2    Mah, M.Z.E.3
  • 6
    • 33748420535 scopus 로고    scopus 로고
    • Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models
    • Allen FR, Ambikairajah E, Lovell NH. Classification of a known sequence of motions and postures from accelerometry data using adapted Gaussian mixture models. Physiol Measure 2006;27:935-951.
    • (2006) Physiol Measure , vol.27 , pp. 935-951
    • Allen, F.R.1    Ambikairajah, E.2    Lovell, N.H.3
  • 7
    • 34249934082 scopus 로고    scopus 로고
    • Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm
    • Bourke AK, O'Brienb JV, Lyons GM. Evaluation of a threshold-based tri-axial accelerometer fall detection algorithm. Gait Posture 2007;26:194-199.
    • (2007) Gait Posture , vol.26 , pp. 194-199
    • Bourke, A.K.1    O'Brienb, J.V.2    Lyons, G.M.3
  • 8
    • 11144352779 scopus 로고    scopus 로고
    • A new portable device for ambulatory monitoring of human posture and walking velocity using miniature accelerometers and gyroscope
    • Tanaka S, Motoi K, Nogawa M, Yamakoshi K. A new portable device for ambulatory monitoring of human posture and walking velocity using miniature accelerometers and gyroscope. Conf Proc IEEE Eng Med Biol Soc 2004;42283-42286
    • (2004) Conf Proc IEEE Eng Med Biol Soc , pp. 42283-42286
    • Tanaka, S.1    Motoi, K.2    Nogawa, M.3    Yamakoshi, K.4
  • 10
    • 24044491541 scopus 로고    scopus 로고
    • Using hierarchical clustering methods to classify motor activities of COPD patients from wearable sensor data
    • Sherrill DM, Moy ML, Relly JJ, Bonato P. Using hierarchical clustering methods to classify motor activities of COPD patients from wearable sensor data. J Neuroeng Rehabil 2005;2:16.
    • (2005) J Neuroeng Rehabil , vol.2 , pp. 16
    • Sherrill, D.M.1    Moy, M.L.2    Relly, J.J.3    Bonato, P.4
  • 11
    • 0037599299 scopus 로고    scopus 로고
    • Ambulatory system for human motion analysis using a kinematic sensor: Monitoring of daily physical activity in the elderly
    • Najafi B, Aminian K, Paraschiv-Ionescu A, Loew F, Büla CJ, Robert P. Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly. IEEE Trans Biomed Eng 2003;50: 711-723.
    • (2003) IEEE Trans Biomed Eng , vol.50 , pp. 711-723
    • Najafi, B.1    Aminian, K.2    Paraschiv-Ionescu, A.3    Loew, F.4    Büla, C.J.5    Robert, P.6
  • 14
    • 0030725217 scopus 로고    scopus 로고
    • Computerized analysis of daily lifemotor activity for ambulatory monitoring
    • Kiani K, Snijders CJ, Gelsema ES. Computerized analysis of daily lifemotor activity for ambulatory monitoring. Technol Health Care 1997;5:307-318.
    • (1997) Technol Health Care , vol.5 , pp. 307-318
    • Kiani, K.1    Snijders, C.J.2    Gelsema, E.S.3
  • 15
    • 38149045656 scopus 로고    scopus 로고
    • A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
    • Bourke AK, Lyons GM. A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor. Med Eng Phys 2008;30:84-90.
    • (2008) Med Eng Phys , vol.30 , pp. 84-90
    • Bourke, A.K.1    Lyons, G.M.2
  • 16
    • 0030821041 scopus 로고    scopus 로고
    • Assessment of posture and motion by multichannel piezoresistive accelerometer recordings
    • Fahrenberg J, Foerster F, Smeja M, Muller W. Assessment of posture and motion by multichannel piezoresistive accelerometer recordings. Psychophysiol 1997;34:607-612.
    • (1997) Psychophysiol , vol.34 , pp. 607-612
    • Fahrenberg, J.1    Foerster, F.2    Smeja, M.3    Muller, W.4
  • 17
    • 0034244011 scopus 로고    scopus 로고
    • Motion pattern and posture: Correctly assessed by calibrated accelerometers
    • Foerster F, Fahrenberg J. Motion pattern and posture: correctly assessed by calibrated accelerometers. Behav Res Meth Instrum Comput 2000;32:450-457.
    • (2000) Behav Res Meth Instrum Comput , vol.32 , pp. 450-457
    • Foerster, F.1    Fahrenberg, J.2
  • 18
    • 0035110824 scopus 로고    scopus 로고
    • Challenges and opportunities for measuring physical activity in sedentary adults
    • Tudor-Locke CE, Myers AM. Challenges and opportunities for measuring physical activity in sedentary adults. Sports Med 2001;31:91-100.
    • (2001) Sports Med , vol.31 , pp. 91-100
    • Tudor-Locke, C.E.1    Myers, A.M.2
  • 19
    • 2342486930 scopus 로고    scopus 로고
    • The design of a practical and reliable fall detector for community and institutional telecare
    • Doughty K, Lewis R, McIntosh A. The design of a practical and reliable fall detector for community and institutional telecare. J Telemed Telecare 2000;6(Suppl 1): S150-S154.
    • (2000) J Telemed Telecare , vol.6 , Issue.SUPPL. 1
    • Doughty, K.1    Lewis, R.2    McIntosh, A.3
  • 20
    • 33744505675 scopus 로고    scopus 로고
    • Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization
    • Nyan MN, Tay FE, Tan AW, Seah KH. Distinguishing fall activities from normal activities by angular rate characteristics and high-speed camera characterization. Med Eng Phys 2006;28:842-849.
    • (2006) Med Eng Phys , vol.28 , pp. 842-849
    • Nyan, M.N.1    Tay, F.E.2    Tan, A.W.3    Seah, K.H.4
  • 21
    • 0031106807 scopus 로고    scopus 로고
    • A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    • Bouten CV, Koekkoek KT, VerduinM, Kodde R, Janssen JD. A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans Biomed Eng 1997;44:136-147.
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 136-147
    • Bouten, C.V.1    Koekkoek, K.T.2    Verduinm Kodde, R.3    Janssen, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.