메뉴 건너뛰기




Volumn 23, Issue 3, 2010, Pages 284-290

Transient neurological symptoms during contrast transcranial doppler right-to-left shunt testing in patients with cryptogenic neurological disease

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN EMBOLISM; CEREBROVASCULAR ACCIDENT; CONTRAST RADIOGRAPHY; DOPPLER ECHOGRAPHY; FEMALE; HEART RIGHT LEFT SHUNT; HUMAN; MAJOR CLINICAL STUDY; MALE; MICROBUBBLE; MICROEMBOLISM; MIGRAINE; MOTOR DYSFUNCTION; NEUROLOGIC DISEASE; NUCLEAR MAGNETIC RESONANCE IMAGING; PARADOXICAL EMBOLISM; PARESIS; PRIORITY JOURNAL; SENSORY DYSFUNCTION; SHUNTING; TRANSIENT ISCHEMIC ATTACK; VERTIGO; VISUAL IMPAIRMENT;

EID: 77953218872     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2010.00557.x     Document Type: Article
Times cited : (9)

References (19)
  • 1
    • 0035031168 scopus 로고    scopus 로고
    • Relationship between right-to-left shunts and cutaneous decompression illness
    • Wilmshurst PT, Pearson MJ, Walsh KP, et al. Relationship between right-to-left shunts and cutaneous decompression illness. Clin Sci (Lond) 2001 100 (5 539 542.
    • (2001) Clin Sci (Lond) , vol.100 , Issue.5 , pp. 539-542
    • Wilmshurst, P.T.1    Pearson, M.J.2    Walsh, K.P.3
  • 2
    • 36749022249 scopus 로고    scopus 로고
    • Diffusion MRI during migraine with aura attack associated with diagnostic microbubbles injection in subjects with large PFO
    • Dinia L, Roccatagliata L, Bonzano L, et al. Diffusion MRI during migraine with aura attack associated with diagnostic microbubbles injection in subjects with large PFO. Headache 2007 47 (10 1455 1456.
    • (2007) Headache , vol.47 , Issue.10 , pp. 1455-1456
    • Dinia, L.1    Roccatagliata, L.2    Bonzano, L.3
  • 3
    • 0021360847 scopus 로고
    • The safety of contrast echocardiography: Report of the Committee on Contrast Echocardiography for the American Society of Echocardiography
    • Bommer WJ, Shah PM, Allen H, et al. The safety of contrast echocardiography: Report of the Committee on Contrast Echocardiography for the American Society of Echocardiography. J Am Coll Cardiol 1984 3 (1 6 13.
    • (1984) J Am Coll Cardiol , vol.3 , Issue.1 , pp. 6-13
    • Bommer, W.J.1    Shah, P.M.2    Allen, H.3
  • 4
    • 58249087556 scopus 로고    scopus 로고
    • Patent foramen ovale and migraine: An example of heart-brain interaction
    • Anzola GP. Patent foramen ovale and migraine: An example of heart-brain interaction. Nat Clin Pract Neurol 2009 5 (1 20 21.
    • (2009) Nat Clin Pract Neurol , vol.5 , Issue.1 , pp. 20-21
    • Anzola, G.P.1
  • 5
    • 1442265540 scopus 로고    scopus 로고
    • The International classification of headache disorders: 2nd edition
    • Headache Classification Subcommittee of the International Headache Society
    • Headache Classification Subcommittee of the International Headache Society. The International classification of headache disorders: 2nd edition. Cephalalgia 2004 24 (Suppl 1 9 160.
    • (2004) Cephalalgia , vol.24 , Issue.SUPPL. 1 , pp. 9-160
  • 6
    • 4944240778 scopus 로고    scopus 로고
    • Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure
    • Spencer MP, Moehring MA, Jesurum J, et al. Power m-mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. J Neuroimaging 2004 14 (4 342 349.
    • (2004) J Neuroimaging , vol.14 , Issue.4 , pp. 342-349
    • Spencer, M.P.1    Moehring, M.A.2    Jesurum, J.3
  • 7
    • 33746831188 scopus 로고    scopus 로고
    • Young adult myocardial infarction and ischemic stroke: The role of paradoxical embolism and thrombophilia (The YAMIS Study)
    • Sastry S, Riding G, Morris J, et al. Young adult myocardial infarction and ischemic stroke: The role of paradoxical embolism and thrombophilia (The YAMIS Study). J Am Coll Cardiol 2006 48 (4 686 691.
    • (2006) J Am Coll Cardiol , vol.48 , Issue.4 , pp. 686-691
    • Sastry, S.1    Riding, G.2    Morris, J.3
  • 8
    • 35649020155 scopus 로고    scopus 로고
    • Migraineurs with patent foramen ovale have larger right-to-left shunt despite similar atrial septal characteristics
    • Jesurum JT, Fuller CJ, Velez CA, et al. Migraineurs with patent foramen ovale have larger right-to-left shunt despite similar atrial septal characteristics. J Headache Pain 2007 8 (4 209 216.
    • (2007) J Headache Pain , vol.8 , Issue.4 , pp. 209-216
    • Jesurum, J.T.1    Fuller, C.J.2    Velez, C.A.3
  • 9
    • 53149095815 scopus 로고    scopus 로고
    • Detection of right-to-left shunts: Comparison between the International Consensus and Spencer Logarithmic Scale criteria
    • Lao AY, Sharma VK, Tsivgoulis G, et al. Detection of right-to-left shunts: Comparison between the International Consensus and Spencer Logarithmic Scale criteria. J Neuroimaging 2008 18 (4 402 406.
    • (2008) J Neuroimaging , vol.18 , Issue.4 , pp. 402-406
    • Lao, A.Y.1    Sharma, V.K.2    Tsivgoulis, G.3
  • 10
    • 0006354851 scopus 로고
    • Karl Pearson and the chi-squared test
    • Plackett R. Karl Pearson and the chi-squared test. Int Stat Rev 1983 51 : 59 72.
    • (1983) Int Stat Rev , vol.51 , pp. 59-72
    • Plackett, R.1
  • 11
    • 27444441375 scopus 로고    scopus 로고
    • Patent foramen ovale: Current pathology, pathophysiology, and clinical status
    • Hara H, Virmani R, Ladich E, et al. Patent foramen ovale: Current pathology, pathophysiology, and clinical status. J Am Coll Cardiol 2005 46 (9 1768 1776.
    • (2005) J Am Coll Cardiol , vol.46 , Issue.9 , pp. 1768-1776
    • Hara, H.1    Virmani, R.2    Ladich, E.3
  • 12
    • 31944446347 scopus 로고    scopus 로고
    • A critical review of patent foramen ovale detection using saline contrast echocardiography: When bubbles lie
    • Woods TD, Patel A. A critical review of patent foramen ovale detection using saline contrast echocardiography: When bubbles lie. J Am Soc Echocardiogr 2006 19 (2 215 222.
    • (2006) J Am Soc Echocardiogr , vol.19 , Issue.2 , pp. 215-222
    • Woods, T.D.1    Patel, A.2
  • 13
    • 0026342729 scopus 로고
    • Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts
    • Nemec JJ, Marwick TH, Lorig RJ, et al. Comparison of transcranial Doppler ultrasound and transesophageal contrast echocardiography in the detection of interatrial right-to-left shunts. Am J Cardiol 1991 68 (15 1498 1502.
    • (1991) Am J Cardiol , vol.68 , Issue.15 , pp. 1498-1502
    • Nemec, J.J.1    Marwick, T.H.2    Lorig, R.J.3
  • 14
    • 33645451063 scopus 로고    scopus 로고
    • Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts
    • Belvis R, Leta RG, Marti-Fabregas J, et al. Almost perfect concordance between simultaneous transcranial Doppler and transesophageal echocardiography in the quantification of right-to-left shunts. J Neuroimaging 2006 16 (2 133 138.
    • (2006) J Neuroimaging , vol.16 , Issue.2 , pp. 133-138
    • Belvis, R.1    Leta, R.G.2    Marti-Fabregas, J.3
  • 15
    • 34248366417 scopus 로고    scopus 로고
    • Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible?
    • Sastry S, Daly K, Chengodu T, et al. Is transcranial Doppler for the detection of venous-to-arterial circulation shunts reproducible? Cerebrovasc Dis 2007 23 (5-6 424 429.
    • (2007) Cerebrovasc Dis , vol.23 , Issue.56 , pp. 424-429
    • Sastry, S.1    Daly, K.2    Chengodu, T.3
  • 16
    • 34447513731 scopus 로고    scopus 로고
    • Spontaneous large right-to-left shunt and migraine headache with aura are risk factors for recurrent stroke in patients with a patent foramen ovale
    • Giardini A, Donti A, Formigari R, et al. Spontaneous large right-to-left shunt and migraine headache with aura are risk factors for recurrent stroke in patients with a patent foramen ovale. Int J Cardiol 2007 120 (3 357 362.
    • (2007) Int J Cardiol , vol.120 , Issue.3 , pp. 357-362
    • Giardini, A.1    Donti, A.2    Formigari, R.3
  • 17
    • 0029937025 scopus 로고    scopus 로고
    • Stroke recurrence in patients with patent foramen ovale: The Lausanne Study. Lausanne Stroke with Paradoxal Embolism Study Group
    • Bogousslavsky J, Garazi S, Jeanrenaud X, et al. Stroke recurrence in patients with patent foramen ovale: The Lausanne Study. Lausanne Stroke with Paradoxal Embolism Study Group. Neurology 1996 46 (5 1301 1305.
    • (1996) Neurology , vol.46 , Issue.5 , pp. 1301-1305
    • Bogousslavsky, J.1    Garazi, S.2    Jeanrenaud, X.3
  • 18
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts. Mayo Clin Proc 1984 59 (1 17 20.
    • (1984) Mayo Clin Proc , vol.59 , Issue.1 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 19
    • 0035793141 scopus 로고    scopus 로고
    • Relation between directly detected patent foramen ovale and ischemic brain lesions in sport divers
    • Schwerzmann M, Seiler C, Lipp E, et al. Relation between directly detected patent foramen ovale and ischemic brain lesions in sport divers. Ann Intern Med 2001 134 (1 21 24.
    • (2001) Ann Intern Med , vol.134 , Issue.1 , pp. 21-24
    • Schwerzmann, M.1    Seiler, C.2    Lipp, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.