Development of a new flat stationary evacuated CPC-collector for process heat applications

Author keywords

CPC collector; Evacuated collector; Solar process heat

Indexed keywords

ABSORBER TUBES; AMBIENT TEMPERATURES; APERTURE AREA; BASIC CONCEPTS; CONCENTRATING COLLECTOR; CONCENTRATION OF; EVACUATED COLLECTOR; EXTRA RADIATION; LOW PRESSURES; PROCESS HEAT; RADIATION LOSS; SOLAR PROCESS;

EID: 77953139713     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2010.03.022     Document Type: Article
Times cited : (76)

References (11)
  • 1
    • 77953139978 scopus 로고    scopus 로고
    • ANSYS Inc, USA
    • ANSYS Inc., 2006. USA. .
    • (2006)
  • 2
    • 77953136341 scopus 로고    scopus 로고
    • Breault Research Organization Inc, USA
    • Breault Research Organization Inc., 1996. USA. .
    • (1996)
  • 4
    • 0019141877 scopus 로고
    • New reflector design which avoids losses through gaps between tubular absorbers and reflectors
    • McIntire W.R. New reflector design which avoids losses through gaps between tubular absorbers and reflectors. Solar Energy 25 (1980) 215-220
    • (1980) Solar Energy , vol.25 , pp. 215-220
    • McIntire, W.R.1
  • 5
    • 0019716324 scopus 로고
    • Design considerations for reduction optical losses due to gaps between absorbers and their reflectors
    • American Section of the International Solar Energy Society
    • McIntire W., and Winston R. Design considerations for reduction optical losses due to gaps between absorbers and their reflectors. Proceedings of Annual Meeting (1981), American Section of the International Solar Energy Society 211-273
    • (1981) Proceedings of Annual Meeting , pp. 211-273
    • McIntire, W.1    Winston, R.2
  • 6
    • 0022510051 scopus 로고
    • Relative cost effectiveness of CPC reflector designs suitable for evacuated absorber tube solar collectors
    • Mills D.R., Bassett I.M., and Derrick G.H. Relative cost effectiveness of CPC reflector designs suitable for evacuated absorber tube solar collectors. Solar Energy 36 3 (1986) 199-206
    • (1986) Solar Energy , vol.36 , Issue.3 , pp. 199-206
    • Mills, D.R.1    Bassett, I.M.2    Derrick, G.H.3
  • 8
    • 0016872797 scopus 로고
    • Comparison of solar concentrators
    • Rabl A. Comparison of solar concentrators. Solar Energy 18 (1975) 93-111
    • (1975) Solar Energy , vol.18 , pp. 93-111
    • Rabl, A.1
  • 9
    • 0016114840 scopus 로고
    • Principles of solar concentrators of a novel design
    • Winston R. Principles of solar concentrators of a novel design. Solar Energy 16 (1974) 89-95
    • (1974) Solar Energy , vol.16 , pp. 89-95
    • Winston, R.1
  • 10
    • 0017886040 scopus 로고
    • Ideal flux concentrators with reflector gaps
    • Winston R. Ideal flux concentrators with reflector gaps. Applied Optics 17 (1978) 1668
    • (1978) Applied Optics , vol.17 , pp. 1668
    • Winston, R.1
  • 11
    • 0016549279 scopus 로고
    • Principles of cylindrical concentrators for solar energy
    • Winston R., and Hinterberger H. Principles of cylindrical concentrators for solar energy. Solar Energy 17 (1975) 255-258
    • (1975) Solar Energy , vol.17 , pp. 255-258
    • Winston, R.1    Hinterberger, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.