메뉴 건너뛰기




Volumn 17, Issue 7, 2010, Pages 884-893

Dual-source CT Angiography in Aortic Stent Grafting. An in vitro Aorta Phantom Study of Image Noise and Radiation Dose

Author keywords

3D visualization; aortic stent graft; image noise; Multislice CT; radiation dose; virtual intravascular endoscopy

Indexed keywords

ANEURYSM; AORTA GRAFT; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC IMAGING; DUAL SOURCE COMPUTED TOMOGRAPHIC ANGIOGRAPHY; ENDOSCOPY; IMAGE QUALITY; IN VITRO STUDY; PHANTOM; PRACTICE GUIDELINE; PRIORITY JOURNAL; RADIATION DOSE; RENAL ARTERY; SIGNAL NOISE RATIO; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; STENT; SUPERIOR MESENTERIC ARTERY; THREE DIMENSIONAL IMAGING; VIRTUAL INTRAVASCULAR ENDOSCOPY; AORTA; AORTOGRAPHY; ARTIFACT; COMPUTER ASSISTED TOMOGRAPHY; DEVICES; EVALUATION STUDY; HUMAN; PHOTON ABSORPTIOMETRY; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SURGERY;

EID: 77953124581     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2010.03.004     Document Type: Article
Times cited : (8)

References (22)
  • 1
    • 0034071614 scopus 로고    scopus 로고
    • Aortic aneurysmal disease: assessment of stent-grafted treatment-CT versus conventional angiography
    • Armerding M.D., Rubin G.D., Beaulieu C.F., et al. Aortic aneurysmal disease: assessment of stent-grafted treatment-CT versus conventional angiography. Radiology 215 (2000) 138-146
    • (2000) Radiology , vol.215 , pp. 138-146
    • Armerding, M.D.1    Rubin, G.D.2    Beaulieu, C.F.3
  • 2
    • 0034764815 scopus 로고    scopus 로고
    • Stent grafting of abdominal aortic aneurysms: pre-and postoperative evaluation with multislice helical CT
    • Rydberg J., Kopecky K.K., Lalka S.G., et al. Stent grafting of abdominal aortic aneurysms: pre-and postoperative evaluation with multislice helical CT. J Comput Assist Tomogr 25 (2001) 580-586
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 580-586
    • Rydberg, J.1    Kopecky, K.K.2    Lalka, S.G.3
  • 3
    • 0035941737 scopus 로고    scopus 로고
    • Coronary angiography with multi-slice computed tomography
    • Nieman K., Oudkerk M., Rensing B.J., et al. Coronary angiography with multi-slice computed tomography. Lancet 357 (2001) 599-603
    • (2001) Lancet , vol.357 , pp. 599-603
    • Nieman, K.1    Oudkerk, M.2    Rensing, B.J.3
  • 4
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography
    • Raff G.L., Gallagher M.J., O'Neill W.W., et al. Diagnostic accuracy of non-invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46 (2005) 552-557
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3
  • 5
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual source CT (DSCT) system
    • Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 6
    • 1042302744 scopus 로고    scopus 로고
    • Diagnostic value of CT virtual intravascular endoscopy in aortic stent grafting
    • Sun Z., Winder J., Kelly B., et al. Diagnostic value of CT virtual intravascular endoscopy in aortic stent grafting. J Endovasc Ther 11 (2004) 13-25
    • (2004) J Endovasc Ther , vol.11 , pp. 13-25
    • Sun, Z.1    Winder, J.2    Kelly, B.3
  • 7
    • 33746823058 scopus 로고    scopus 로고
    • Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: in vitro phantom study
    • Sun Z., and Taylor C. Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: in vitro phantom study. Eur J Radiol 58 (2006) 310-316
    • (2006) Eur J Radiol , vol.58 , pp. 310-316
    • Sun, Z.1    Taylor, C.2
  • 8
    • 4544223137 scopus 로고    scopus 로고
    • Multislice CT virtual intravascular endoscopy for abdominal aortic aneurysm stent grafts
    • Sun Z., and Gallagher E. Multislice CT virtual intravascular endoscopy for abdominal aortic aneurysm stent grafts. J Vasc Intervent Radiol 15 (2004) 961-970
    • (2004) J Vasc Intervent Radiol , vol.15 , pp. 961-970
    • Sun, Z.1    Gallagher, E.2
  • 10
    • 70350517464 scopus 로고    scopus 로고
    • Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose
    • 56-64
    • Baumuller S., Leschka S., Desbiolles L., et al. Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose. Radiology 253 (2009) 56-64
    • (2009) Radiology , vol.253
    • Baumuller, S.1    Leschka, S.2    Desbiolles, L.3
  • 11
    • 35148867562 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source multi-slice CT coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    • Leber A.W., Johnson T., Becker A., et al. Diagnostic accuracy of dual-source multi-slice CT coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 28 (2007) 2354-2360
    • (2007) Eur Heart J , vol.28 , pp. 2354-2360
    • Leber, A.W.1    Johnson, T.2    Becker, A.3
  • 12
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as function of patient weight at abdominal CT
    • Huda W., Scalzetti E.M., and Levin G. Technique factors and image quality as function of patient weight at abdominal CT. Radiology 217 (2000) 430-435
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 13
    • 49049083272 scopus 로고    scopus 로고
    • Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
    • Leschka S., Stolzmann P., Schimid F.T., et al. Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 18 (2008) 1809-1817
    • (2008) Eur Radiol , vol.18 , pp. 1809-1817
    • Leschka, S.1    Stolzmann, P.2    Schimid, F.T.3
  • 14
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice
    • Hausleiter J., Meyer T., Hadamitzky M., et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice. Circulation 113 (2006) 1305-1310
    • (2006) Circulation , vol.113 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3
  • 15
    • 63849123042 scopus 로고    scopus 로고
    • Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography
    • Pflederer T., Rudofsky L., Ropers D., et al. Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography. AJR Am J Roentgenol 192 (2009) 1045-1050
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 1045-1050
    • Pflederer, T.1    Rudofsky, L.2    Ropers, D.3
  • 16
    • 66849138266 scopus 로고    scopus 로고
    • The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography
    • Park E.A., Lee W., Kang J.H., et al. The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography. Korean J Radiol 10 (2009) 235-243
    • (2009) Korean J Radiol , vol.10 , pp. 235-243
    • Park, E.A.1    Lee, W.2    Kang, J.H.3
  • 17
    • 45849097583 scopus 로고    scopus 로고
    • Multislice CT angiography in post-aortic stent grafting: optimization of scanning protocols for virtual intravascular endoscopy
    • Sun Z. Multislice CT angiography in post-aortic stent grafting: optimization of scanning protocols for virtual intravascular endoscopy. Int J CARS 3 (2008) 19-26
    • (2008) Int J CARS , vol.3 , pp. 19-26
    • Sun, Z.1
  • 18
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospective electrocardiogram-triggered high-pitch spiral acquisition
    • Achenbach S., Marvan M., Ropers D., et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospective electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 31 (2010) 340-346
    • (2010) Eur Heart J , vol.31 , pp. 340-346
    • Achenbach, S.1    Marvan, M.2    Ropers, D.3
  • 19
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose
    • Earls J.P., Berman E.L., Urban B.A., et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246 (2008) 742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 20
    • 78149358229 scopus 로고    scopus 로고
    • Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: comparison with retrospective ECG gating
    • (in press)
    • Xu L., Yang L., Zhang Z., et al. Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: comparison with retrospective ECG gating. Eur J Radiol (2009) (in press)
    • (2009) Eur J Radiol
    • Xu, L.1    Yang, L.2    Zhang, Z.3
  • 21
    • 49449110640 scopus 로고    scopus 로고
    • Multislice CT angiography in the follow-up of fenestrated endovascular grafts: effect of slice thickness on 2D and 3D visualization of the fenestrated stents
    • Sun Z., Allen Y., Bibombe P., et al. Multislice CT angiography in the follow-up of fenestrated endovascular grafts: effect of slice thickness on 2D and 3D visualization of the fenestrated stents. J Endovasc Ther 15 (2008) 417-426
    • (2008) J Endovasc Ther , vol.15 , pp. 417-426
    • Sun, Z.1    Allen, Y.2    Bibombe, P.3
  • 22
    • 18444384843 scopus 로고    scopus 로고
    • Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms
    • Stavropoulos S.W., Clark T.W.I., Carpenter J.P., et al. Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 16 (2005) 663-667
    • (2005) J Vasc Interv Radiol , vol.16 , pp. 663-667
    • Stavropoulos, S.W.1    Clark, T.W.I.2    Carpenter, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.