메뉴 건너뛰기




Volumn 89, Issue 5, 2010, Pages 1649-1651

Late Cardiac Perforation After Transcatheter Closure of Patent Foramen Ovale Mimicking Acute Type A Aortic Dissection

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AORTA DISSECTION; ARTICLE; CARDIOGENIC SHOCK; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ERROR; ECHOCARDIOGRAPHY; FEMALE; HEART ARREST; HEART INJURY; HEART TAMPONADE; HEMOPERICARDIUM; HUMAN; HYPOTENSION; PATENT FORAMEN OVALE; PERFORATION; PRIORITY JOURNAL; RESUSCITATION; STERNOTOMY; SYNCOPE; THORAX PAIN; TRANSTHORACIC ECHOCARDIOGRAPHY; BALLOON OCCLUSION; CRITICAL ILLNESS; DEVICE REMOVAL; DIFFERENTIAL DIAGNOSIS; DISSECTING ANEURYSM; DOPPLER ECHOCARDIOGRAPHY; EMERGENCY TREATMENT; HEART CATHETERIZATION; HEART SURGERY; INSTRUMENTATION; METHODOLOGY; RISK ASSESSMENT; THORACIC AORTA ANEURYSM; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TREATMENT OUTCOME;

EID: 77953039740     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2009.09.079     Document Type: Article
Times cited : (6)

References (6)
  • 1
    • 17144396704 scopus 로고    scopus 로고
    • Cardiac perforation after device closure of atrial septal defects with the Amplatzer Septal Occluder
    • Divekar A., Gaamangwe T., Shaikh N., et al. Cardiac perforation after device closure of atrial septal defects with the Amplatzer Septal Occluder. J Am Coll Cardiol 45 (2005) 1213-1218
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1213-1218
    • Divekar, A.1    Gaamangwe, T.2    Shaikh, N.3
  • 2
    • 9644275542 scopus 로고    scopus 로고
    • Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk
    • Amin Z., Hijazi Z.M., Bass J.L., et al. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 63 (2004) 496-502
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 496-502
    • Amin, Z.1    Hijazi, Z.M.2    Bass, J.L.3
  • 3
    • 28244477558 scopus 로고    scopus 로고
    • Late cardiac tamponade after percutaneous closure of a patent foramen ovale
    • Christen T., Mach F., Didier D., et al. Late cardiac tamponade after percutaneous closure of a patent foramen ovale. Eur J Echocardiogr 6 (2005) 465-469
    • (2005) Eur J Echocardiogr , vol.6 , pp. 465-469
    • Christen, T.1    Mach, F.2    Didier, D.3
  • 4
    • 39649120113 scopus 로고    scopus 로고
    • Minimally invasive video-assisted surgery for iatrogenic aortic root to right atrium fistula after incomplete percutaneous occlusion of patent foramen ovale: case report and review of the literature
    • Raffa G.M., Pellegrini C., Lentini S., et al. Minimally invasive video-assisted surgery for iatrogenic aortic root to right atrium fistula after incomplete percutaneous occlusion of patent foramen ovale: case report and review of the literature. J Card Surg 23 (2008) 63-78
    • (2008) J Card Surg , vol.23 , pp. 63-78
    • Raffa, G.M.1    Pellegrini, C.2    Lentini, S.3
  • 5
    • 60149091011 scopus 로고    scopus 로고
    • Interatrial septal closure devices and aortic perforation: a note of caution
    • Schoen S.P., Wiedeman S., Bock M., et al. Interatrial septal closure devices and aortic perforation: a note of caution. J Invasive Cardiol 21 (2009) E39-E41
    • (2009) J Invasive Cardiol , vol.21
    • Schoen, S.P.1    Wiedeman, S.2    Bock, M.3
  • 6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.