메뉴 건너뛰기




Volumn 48, Issue 2, 2010, Pages 247-250

Ethmoid roof CSF-leak following frontal sinus balloon sinuplasty

Author keywords

Balloon sinuplasty; Complications; CSF leak; Sinus balloon catheter

Indexed keywords

ADULT; ARTICLE; BALLOON DILATATION; CASE REPORT; CEREBROSPINAL FLUID RHINORRHEA; ETHMOID BONE; ETHMOID SINUS; FEMALE; FRONTAL SINUSITIS; HUMAN; POSTOPERATIVE COMPLICATION;

EID: 77952967907     PISSN: 03000729     EISSN: None     Source Type: Journal    
DOI: 10.4193/Rhin09.129     Document Type: Article
Times cited : (35)

References (15)
  • 1
    • 33746119581 scopus 로고    scopus 로고
    • Catheter-based dilation of the sinus ostia: Initial safety and feasibility analysis in a cadaver model
    • Bolger WE, Vaughan WC. Catheter-based dilation of the sinus ostia: initial safety and feasibility analysis in a cadaver model. Am J Rhinol. 2006; 20: 290-294.
    • (2006) Am J Rhinol. , vol.20 , pp. 290-294
    • Bolger, W.E.1    Vaughan, W.C.2
  • 2
    • 33646008290 scopus 로고    scopus 로고
    • Safety and feasibility of balloon catheter dilation of paranasal sinus ostia: A preliminary investigation
    • Brown CL, Bolger WE. Safety and feasibility of balloon catheter dilation of paranasal sinus ostia: a preliminary investigation. Ann Otol Rhinol Laryngol. 2006; 115: 293-301.
    • (2006) Ann Otol Rhinol Laryngol. , vol.115 , pp. 293-301
    • Brown, C.L.1    Bolger, W.E.2
  • 3
    • 60549102288 scopus 로고    scopus 로고
    • Feasibility of balloon dilatation in endoscopic sinus surgery simulator
    • Stamm A, Nogueira JF, Lyra M. Feasibility of balloon dilatation in endoscopic sinus surgery simulator. Otolaryngol Head Neck Surg. 2009; 140: 320-323.
    • (2009) Otolaryngol Head Neck Surg. , vol.140 , pp. 320-323
    • Stamm, A.1    Nogueira, J.F.2    Lyra, M.3
  • 5
    • 33750071722 scopus 로고    scopus 로고
    • Balloon sinuplasty: Not ready for prime time
    • Lanza DC, Kennedy DW. Balloon sinuplasty: not ready for prime time. Ann Otol Rhinol Laryngol. 2006; 115: 789-792.
    • (2006) Ann Otol Rhinol Laryngol. , vol.115 , pp. 789-792
    • Lanza, D.C.1    Kennedy, D.W.2
  • 6
    • 49149093587 scopus 로고    scopus 로고
    • The balloon dilating catheter as an instrument in sinus surgery
    • Melroy CT. The balloon dilating catheter as an instrument in sinus surgery. Otolaryngol Head Neck Surg. 2008; 139: S23-26.
    • (2008) Otolaryngol Head Neck Surg. , vol.139
    • Melroy, C.T.1
  • 7
    • 62849094281 scopus 로고    scopus 로고
    • Balloon sinuplasty for the surgical management of immunocompromised and critically ill patients with acute rhinosinusitis
    • Wittkopf ML, Becker SS, Duncavage JA, Russell PT. Balloon sinuplasty for the surgical management of immunocompromised and critically ill patients with acute rhinosinusitis. Otolaryngol Head Neck Surg. 2009; 140: 596-598.
    • (2009) Otolaryngol Head Neck Surg. , vol.140 , pp. 596-598
    • Wittkopf, M.L.1    Becker, S.S.2    Duncavage, J.A.3    Russell, P.T.4
  • 9
    • 62449286114 scopus 로고    scopus 로고
    • Safety and feasibility of balloon sinuplasty for treatment of chronic rhinosinusitis in children
    • Ramadan HH. Safety and feasibility of balloon sinuplasty for treatment of chronic rhinosinusitis in children. Ann Otol Rhinol Laryngol. 2009; 118: 161-165.
    • (2009) Ann Otol Rhinol Laryngol. , vol.118 , pp. 161-165
    • Ramadan, H.H.1
  • 10
    • 62449267364 scopus 로고    scopus 로고
    • Balloon dilation of the frontal recess in patients with chronic frontal sinusitis and advanced sinus disease: An initial report
    • Catalano PJ, Payne SC. Balloon dilation of the frontal recess in patients with chronic frontal sinusitis and advanced sinus disease: an initial report. Ann Otol Rhinol Laryngol. 2009; 118: 107-112.
    • (2009) Ann Otol Rhinol Laryngol. , vol.118 , pp. 107-112
    • Catalano, P.J.1    Payne, S.C.2
  • 11
    • 77953019323 scopus 로고    scopus 로고
    • U.S. Food Drug Administration.Manufacturer and User Facility Device Experience (MAUDE) Database. Available at
    • U.S. Food and Drug Administration. Manufacturer and User Facility Device Experience (MAUDE) Database. Available at: http//www.accessdata.fda.gov/scripts/ cdrh/cfdocs/cfMAUDE/searchCFM.
  • 15
    • 42149105639 scopus 로고    scopus 로고
    • Multicenter registry of balloon catheter sinusotomy outcomes for 1,036 patients
    • PatiENT Registry Study Group
    • Levine HL, Sertich AP 2nd, Hoisington DR, Weiss RL, Pritikin J; PatiENT Registry Study Group. Multicenter registry of balloon catheter sinusotomy outcomes for 1,036 patients. Ann Otol Rhinol Laryngol. 2008; 117: 263-270.
    • (2008) Ann Otol Rhinol Laryngol. , vol.117 , pp. 263-270
    • Levine, H.L.1    Sertich II., A.P.2    Hoisington, D.R.3    Weiss, R.4    Pritikin, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.