메뉴 건너뛰기




Volumn 66, Issue 6, 2010, Pages 1050-1057

Transcranial doppler pulsatility index: Not an accurate method to assess intracranial pressure

Author keywords

Blood flow velocity; Hydrocephalus; Intracranial pressure; Middle cerebral artery; Pulsatility index

Indexed keywords

ACCURACY; AGED; ARTICLE; BLOOD FLOW VELOCITY; CEREBROSPINAL FLUID SHUNTING; CLINICAL ARTICLE; COMPUTER SIMULATION; CORRELATION ANALYSIS; DOPPLER ECHOGRAPHY; HEMODYNAMICS; HUMAN; INTRACRANIAL PRESSURE; MATHEMATICAL ANALYSIS; MIDDLE CEREBRAL ARTERY; NORMOTENSIVE HYDROCEPHALUS; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SENSOR;

EID: 77952966777     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000369519.35932.F2     Document Type: Article
Times cited : (100)

References (35)
  • 1
    • 4644265911 scopus 로고    scopus 로고
    • Intracranial pressure, I: Historical overview and basic concepts
    • Andrews PJ, Citerio G. Intracranial pressure, I: historical overview and basic concepts. Intensive Care Med. 2004;30(9):1730-1733.
    • (2004) Intensive Care Med. , vol.30 , Issue.9 , pp. 1730-1733
    • Andrews, P.J.1    Citerio, G.2
  • 2
    • 7944226340 scopus 로고    scopus 로고
    • Intracranial pressure, II: Clinical applications and technology
    • Citerio G, Andrews PJ. Intracranial pressure, II: clinical applications and technology. Intensive Care Med. 2004;30(10):1882-1885.
    • (2004) Intensive Care Med. , vol.30 , Issue.10 , pp. 1882-1885
    • Citerio, G.1    Andrews, P.J.2
  • 3
    • 16844384736 scopus 로고    scopus 로고
    • Clinical experience with the intraparenchymal intracranial pressure monitoring codman MicroSensor system
    • Koskinen LO, Olivecrona M. Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system. Neurosurgery. 2005;56(4):693-698.
    • (2005) Neurosurgery , vol.56 , Issue.4 , pp. 693-698
    • Koskinen, L.O.1    Olivecrona, M.2
  • 4
    • 0020702495 scopus 로고
    • A clinical comparison of subdural screw pressure measurements with ventricular pressure
    • Mendelow AD, Rowan JO, Murray L, Kerr AE. A clinical comparison of subdural screw pressure measurements with ventricular pressure. J Neurosurg. 1983;58(1):45-50.
    • (1983) J. Neurosurg. , vol.58 , Issue.1 , pp. 45-50
    • Mendelow, A.D.1    Rowan, J.O.2    Murray, L.3    Kerr, A.E.4
  • 5
    • 0029851897 scopus 로고    scopus 로고
    • A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure
    • Gray W P, Palmer JD, Gill J, Gardner M, Iannotti F. A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure. Neurosurgery. 1996;39(5):927-932.
    • (1996) Neurosurgery , vol.39 , Issue.5 , pp. 927-932
    • Gray, W.P.1    Palmer, J.D.2    Gill, J.3    Gardner, M.4    Iannotti, F.5
  • 6
    • 0031927702 scopus 로고    scopus 로고
    • Reliability of epidural pressure measurement in clinical practice: Behavior of three modern sensors during simultaneous ipsilateral intraventricular or intraparenchymal pressure measurement
    • Raabe A, Totzauer R, Meyer O, Stöckel R, Hohrein D, Schöche J. Reliability of epidural pressure measurement in clinical practice: behavior of three modern sensors during simultaneous ipsilateral intraventricular or intraparenchymal pressure measurement. Neurosurgery. 1998;43(2):306-311.
    • (1998) Neurosurgery , vol.43 , Issue.2 , pp. 306-311
    • Raabe, A.1    Totzauer, R.2    Meyer, O.3    Stöckel, R.4    Hohrein, D.5    Schöche, J.6
  • 7
    • 33846058376 scopus 로고    scopus 로고
    • CSF pressure assessed by lumbar puncture agrees with intracranial pressure
    • Lenfeldt N, Koskinen LO, Bergenheim AT, Malm J, Eklund A. CSF pressure assessed by lumbar puncture agrees with intracranial pressure. Neurology. 2007;68(2):155-158.
    • (2007) Neurology , vol.68 , Issue.2 , pp. 155-158
    • Lenfeldt, N.1    Koskinen, L.O.2    Bergenheim, A.T.3    Malm, J.4    Eklund, A.5
  • 8
    • 0033381818 scopus 로고    scopus 로고
    • The impact of raised intracranial pressure on cerebral venous hemodynamics: A prospective venous transcranial Doppler ultrasonography study
    • Schoser BG, Riemenschneider N, Hansen HC. The impact of raised intracranial pressure on cerebral venous hemodynamics: a prospective venous transcranial Doppler ultrasonography study. J Neurosurg. 1999;91(5):744-749.
    • (1999) J. Neurosurg. , vol.91 , Issue.5 , pp. 744-749
    • Schoser, B.G.1    Riemenschneider, N.2    Hansen, H.C.3
  • 9
    • 0023803670 scopus 로고
    • Evaluation of intracranial pressure from transcranial Doppler studies in cerebral disease
    • Klingelhöfer J, Conrad B, Benecke R, Sander D, Markakis E. Evaluation of intracranial pressure from transcranial Doppler studies in cerebral disease. J Neurol. 1988;235(3):159-162.
    • (1988) J. Neurol. , vol.235 , Issue.3 , pp. 159-162
    • Klingelhöfer, J.1    Conrad, B.2    Benecke, R.3    Sander, D.4    Markakis, E.5
  • 10
    • 0033693419 scopus 로고    scopus 로고
    • MR-intracranial pressure (ICP) : A method to measure intracranial elastance and pressure noninvasively by means of MR imaging: Baboon and human study
    • Alperin NJ, Lee SH, Loth F, Raksin PB, Lichtor T. MR-intracranial pressure (ICP) : a method to measure intracranial elastance and pressure noninvasively by means of MR imaging: baboon and human study. Radiology. 2000;217(3):877-885.
    • (2000) Radiology , vol.217 , Issue.3 , pp. 877-885
    • Alperin, N.J.1    Lee, S.H.2    Loth, F.3    Raksin, P.B.4    Lichtor, T.5
  • 11
    • 0034635903 scopus 로고    scopus 로고
    • Intraocular pressure changes and alterations in intracranial pressure
    • Sheeran P, Bland JM, Hall GM. Intraocular pressure changes and alterations in intracranial pressure. Lancet. 2000;355(9207):899.
    • (2000) Lancet , vol.355 , Issue.9207 , pp. 899
    • Sheeran, P.1    Bland, J.M.2    Hall, G.M.3
  • 12
    • 0031811953 scopus 로고    scopus 로고
    • Tympanic membrane displacement testing in regular assessment of intracranial pressure in eight children with shunted hydrocephalus
    • Samuel M, Burge DM, Marchbanks RJ. Tympanic membrane displacement testing in regular assessment of intracranial pressure in eight children with shunted hydrocephalus. J Neurosurg. 1998;88(6):983-995. (Pubitemid 28261844)
    • (1998) Journal of Neurosurgery , vol.88 , Issue.6 , pp. 983-995
    • Samuel, M.1    Burge, D.M.2    Marchbanks, R.J.3
  • 13
    • 0036557881 scopus 로고    scopus 로고
    • Investigation of intracranial media ultrasonic monitoring model
    • Petkus V, Ragauskas A, Jurkonis R. Investigation of intracranial media ultrasonic monitoring model. Ultrasonics. 2002; 40 (1-8) : 829-833.
    • (2002) Ultrasonics , vol.40 , Issue.1-8 , pp. 829-833
    • Petkus, V.1    Ragauskas, A.2    Jurkonis, R.3
  • 14
    • 2442691906 scopus 로고    scopus 로고
    • MR-intracranial compliance and pressure: A method for noninvasive measurement of important neurophysiologic parameters
    • Alperin N. MR-intracranial compliance and pressure: a method for noninvasive measurement of important neurophysiologic parameters. Methods Enzymol. 2004;386:323-349.
    • (2004) Methods Enzymol , vol.386 , pp. 323-349
    • Alperin, N.1
  • 15
    • 3042763982 scopus 로고    scopus 로고
    • Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)
    • Bellner J, Romner B, Reinstrup P, Kristiansson KA, Ryding E, Brandt L. Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP). Surg Neurol. 2004;62(1):45-51.
    • (2004) Surg. Neurol. , vol.62 , Issue.1 , pp. 45-51
    • Bellner, J.1    Romner, B.2    Reinstrup, P.3    Kristiansson, K.A.4    Ryding, E.5    Brandt, L.6
  • 16
    • 0023726127 scopus 로고
    • A mathematical study of human intracranial hydrodynamics, I: The cerebrospinal fluid pulse pressure
    • Ursino M. A mathematical study of human intracranial hydrodynamics, I: the cerebrospinal fluid pulse pressure. Ann Biomed Eng. 1988;16(4):379-401.
    • (1988) Ann. Biomed. Eng. , vol.16 , Issue.4 , pp. 379-401
    • Ursino, M.1
  • 17
    • 0142042959 scopus 로고    scopus 로고
    • Quantitative assessment of cerebral autoregulation from transcranial Doppler pulsatility: A computer simulation study
    • Ursino M, Giulioni M. Quantitative assessment of cerebral autoregulation from transcranial Doppler pulsatility: a computer simulation study. Med Eng Phys. 2003;25(8):655-666.
    • (2003) Med. Eng. Phys. , vol.25 , Issue.8 , pp. 655-666
    • Ursino, M.1    Giulioni, M.2
  • 18
    • 0034873164 scopus 로고    scopus 로고
    • Cere - Brospinal fluid hydrodynamics after placement of a shunt with an antisiphon device: A long-term study
    • Lundkvist B, Eklund A, Kristensen B, Fagerlund M, Koskinen LO, Malm J. Cere - brospinal fluid hydrodynamics after placement of a shunt with an antisiphon device: a long-term study. J Neurosurg. 2001;94(5):750-756.
    • (2001) J. Neurosurg. , vol.94 , Issue.5 , pp. 750-756
    • Lundkvist, B.1    Eklund, A.2    Kristensen, B.3    Fagerlund, M.4    Koskinen, L.O.5    Malm, J.6
  • 19
    • 0020394689 scopus 로고
    • Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
    • Aaslid R, Markwalder TM, Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg. 1982;57(6):769-774.
    • (1982) J. Neurosurg. , vol.57 , Issue.6 , pp. 769-774
    • Aaslid, R.1    Markwalder, T.M.2    Nornes, H.3
  • 20
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statistician. 1983;32:307-317.
    • (1983) Statistician , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 21
    • 13844253484 scopus 로고    scopus 로고
    • Early cerebral monitoring using the transcranial Doppler pulsatility index in patients with severe brain trauma
    • Voulgaris SG, Partheni M, Kaliora H, Haftouras N, Pessach IS, Polyzoidis KS. Early cerebral monitoring using the transcranial Doppler pulsatility index in patients with severe brain trauma. Med Sci Monit. 2005;11(2):49-52.
    • (2005) Med. Sci. Monit , vol.11 , Issue.2 , pp. 49-52
    • Voulgaris, S.G.1    Partheni, M.2    Kaliora, H.3    Haftouras, N.4    Pessach, I.S.5    Polyzoidis, K.S.6
  • 22
    • 2442458265 scopus 로고    scopus 로고
    • Evaluating the outcome of severe head injury with transcranial Doppler ultrasonography
    • Moreno JA, Mesalles E, Gener J, et al. Evaluating the outcome of severe head injury with transcranial Doppler ultrasonography. Neurosurg Focus. 2000; 8 (1) : e8.
    • (2000) Neurosurg. Focus , vol.8 , Issue.1
    • Moreno, J.A.1    Mesalles, E.2    Gener, J.3
  • 23
    • 0027158122 scopus 로고
    • Transcranial Doppler recordings in raised intracranial pressure
    • Homburg AM, Jakobsen M, Enevoldsen E. Transcranial Doppler recordings in raised intracranial pressure. Acta Neurol Scand. 1993;87(6):488-493.
    • (1993) Acta Neurol. Scand. , vol.87 , Issue.6 , pp. 488-493
    • Homburg, A.M.1    Jakobsen, M.2    Enevoldsen, E.3
  • 24
    • 0018200060 scopus 로고
    • Autoregulation and CO2 responses of cerebral blood flow in patients with acute severe head injury
    • Enevoldsen EM, Jensen FT. Autoregulation and CO2 responses of cerebral blood flow in patients with acute severe head injury. J Neurosurg. 1978;48(5):689-703.
    • (1978) J. Neurosurg. , vol.48 , Issue.5 , pp. 689-703
    • Enevoldsen, E.M.1    Jensen, F.T.2
  • 25
    • 0016148670 scopus 로고
    • Control of cerebral circulation in health and disease
    • Lassen NA. Control of cerebral circulation in health and disease. Circ Res. 1974;34(6):749-760.
    • (1974) Circ. Res. , vol.34 , Issue.6 , pp. 749-760
    • Lassen, N.A.1
  • 26
    • 0034062134 scopus 로고    scopus 로고
    • Arterial pulsatility as an index of cerebral microangiopathy in diabetes
    • Lee KY, Sohn YH, Baik JS, Kim G W, Kim JS. Arterial pulsatility as an index of cerebral microangiopathy in diabetes. Stroke. 2000;31(5):1111-1115.
    • (2000) Stroke , vol.31 , Issue.5 , pp. 1111-1115
    • Lee, K.Y.1    Sohn, Y.H.2    Baik, J.S.3    Kim, G.W.4    Kim, J.S.5
  • 27
    • 0344431353 scopus 로고    scopus 로고
    • Noninvasive prediction of intracranial pressure curves using transcranial Doppler ultrasonography and blood pressure curves
    • Schmidt B, Klingelhöfer J, Schwarze JJ, Sander D, Wittich I. Noninvasive prediction of intracranial pressure curves using transcranial Doppler ultrasonography and blood pressure curves. Stroke. 1997;28(12):2465- 2472.
    • (1997) Stroke , vol.28 , Issue.12 , pp. 2465-2472
    • Schmidt, B.1    Klingelhöfer, J.2    Schwarze, J.J.3    Sander, D.4    Wittich, I.5
  • 28
    • 2442450690 scopus 로고    scopus 로고
    • Pattern of white matter regional cerebral blood flow and autoregulation in normal pressure hydrocephalus
    • Pt
    • Momjian S, Owler BK, Czosnyka Z, Czosnyka M, Pena A, Pickard JD. Pattern of white matter regional cerebral blood flow and autoregulation in normal pressure hydrocephalus. Brain. 2004; 127 (Pt 5) : 965-972.
    • (2004) Brain , vol.127 , Issue.5 , pp. 965-972
    • Momjian, S.1    Owler, B.K.2    Czosnyka, Z.3    Czosnyka, M.4    Pena, A.5    Pickard, J.D.6
  • 29
    • 0030994643 scopus 로고    scopus 로고
    • Cerebral blood flow and autoregulation in normal pressure hydrocephalus
    • DOI 10.1097/00006123-199706000-00009
    • Tanaka A, Kimura M, Nakayama Y, Yoshinaga S, Tomonaga M. Cerebral blood flow and autoregulation in normal pressure hydrocephalus. Neurosurgery. 1997;40(6):1161-1167. (Pubitemid 27251667)
    • (1997) Neurosurgery , vol.40 , Issue.6 , pp. 1161-1167
    • Tanaka, A.1    Kimura, M.2    Nakayama, Y.3    Yoshinaga, S.4    Tomonaga, M.5
  • 30
    • 0030025798 scopus 로고    scopus 로고
    • Vascular risk factors and arteriosclerotic disease in idiopathic normal-pressure hydrocephalus of the elderly
    • Krauss JK, Regel J P, Vach W, Droste DW, Borremans JJ, Mergner T. Vascular risk factors and arteriosclerotic disease in idiopathic normal-pressure hydrocephalus of the elderly. Stroke. 1996;27(1):24-29.
    • (1996) Stroke , vol.27 , Issue.1 , pp. 24-29
    • Krauss, J.K.1    Regel, J.P.2    Vach, W.3    Droste, D.W.4    Borremans, J.J.5    Mergner, T.6
  • 31
    • 0028025595 scopus 로고
    • Transcranial Doppler and duplex ultrasound: Where is the method helpful?
    • German
    • Widder B. Transcranial Doppler and duplex ultrasound: where is the method helpful? [in German]. Ultraschall Med. 1994;15(4):174-177.
    • (1994) Ultraschall Med. , vol.15 , Issue.4 , pp. 174-177
    • Widder, B.1
  • 32
    • 0023864141 scopus 로고
    • Age dependence of the flow velocity in the basal cerebral arteries: A transcranial Doppler ultrasound study
    • Grolimund P, Seiler RW. Age dependence of the flow velocity in the basal cerebral arteries: a transcranial Doppler ultrasound study. Ultrasound Med Biol. 1988;14(3):191-198.
    • (1988) Ultrasound Med. Biol. , vol.14 , Issue.3 , pp. 191-198
    • Grolimund, P.1    Seiler, R.W.2
  • 35
    • 0029063488 scopus 로고
    • Clinical evaluation of a miniature strain-gauge transducer for monitoring intracranial pressure
    • Gopinath S P, Robertson CS, Contant CF, Narayan RK, Grossman RG. Clinical evaluation of a miniature strain-gauge transducer for monitoring intracranial pressure. Neurosurgery. 1995;36(6):1137-1141.
    • (1995) Neurosurgery , vol.36 , Issue.6 , pp. 1137-1141
    • Gopinath, S.P.1    Robertson, C.S.2    Contant, C.F.3    Narayan, R.K.4    Grossman, R.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.