메뉴 건너뛰기




Volumn 68, Issue 7-8, 2010, Pages 1438-1440

Characterisation, modelling and optimisation of the model of a HPGe detector with the aid of point sources

Author keywords

Detector model; HPGe detectors; ISOCS; MCNPX; Monte Carlo; Point source measurements

Indexed keywords

CANBERRA; CHARACTERISATION; COUNT RATES; DETECTOR MODELS; HPGE DETECTORS; INCOMPLETE KNOWLEDGE; INNER STRUCTURE; LOW ENERGY PHOTONS; MONTE CARLO; OPTIMISATIONS; PARAMETRIC SIMULATIONS; POINT SOURCE MEASUREMENTS; POINT SOURCES; VIRTUAL MODELS;

EID: 77952955564     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2009.11.022     Document Type: Article
Times cited : (16)

References (6)
  • 1
    • 77952954551 scopus 로고    scopus 로고
    • Canberra Industries, Inc., Model S573 ISOCS Calibration Software v. 4.
    • Canberra Industries, Inc., 2002. Model S573 ISOCS Calibration Software v. 4.
    • , vol.2002
  • 2
    • 77952951277 scopus 로고    scopus 로고
    • Canberra Industries, Inc., Genie 2000 Spectroscopy Software Manual v. 3.1.
    • Canberra Industries, Inc., 2006. Genie 2000 Spectroscopy Software Manual v. 3.1.
    • , vol.2006
  • 3
    • 65249166904 scopus 로고    scopus 로고
    • Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL-torso-phantom
    • Hegenbart L., Marzocchi O., Breustedt B., Urban M. Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL-torso-phantom. Radiation Protection Dosimetry 2009, 133(3):158-164.
    • (2009) Radiation Protection Dosimetry , vol.133 , Issue.3 , pp. 158-164
    • Hegenbart, L.1    Marzocchi, O.2    Breustedt, B.3    Urban, M.4
  • 4
    • 77952957807 scopus 로고    scopus 로고
    • Microsoft Corporation, Microsoft Office Excel 2003 (11.8220.8202) SP3.
    • Microsoft Corporation, 2003. Microsoft Office Excel 2003 (11.8220.8202) SP3.
    • , vol.2003
  • 5
    • 77952954363 scopus 로고    scopus 로고
    • Pelowitz, D.B., (Ed.), MCNPX User's manual version 2.6.0. Los Alamos National Laboratory Report LA-CP-05-0369.
    • Pelowitz, D.B., (Ed.), 2008. MCNPX User's manual version 2.6.0. Los Alamos National Laboratory Report LA-CP-05-0369.
    • , vol.2008
  • 6
    • 34548219177 scopus 로고    scopus 로고
    • Precise modelling of coaxial germanium detectors in preparation for a mathematical calibration
    • Schlaeger M. Precise modelling of coaxial germanium detectors in preparation for a mathematical calibration. Nuclear Instruments and Methods in Physics Research Section A 2007, 580:137-140.
    • (2007) Nuclear Instruments and Methods in Physics Research Section A , vol.580 , pp. 137-140
    • Schlaeger, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.