메뉴 건너뛰기




Volumn 112, Issue 6, 2010, Pages 530-536

Direct measurement of patient's entrance skin dose during neurointerventional procedure to avoid further radiation-induced skin injuries

Author keywords

Dural arteriovenous fistula; Entrance skin dose; Neurointerventional procedure; Radiation induced skin injury; Radiophotoluminescence glass dosimeter; Temporary epilation

Indexed keywords

ADULT; ARTICLE; BRAIN ARTERIOVENOUS MALFORMATION; CASE REPORT; CAVERNOUS SINUS; COIL EMBOLIZATION; DOSIMETER; DOSIMETRY; HUMAN; MALE; PHOTOLUMINESCENCE; RADIATION DOSE; RADIATION INJURY; SKIN INJURY; X RAY TUBE;

EID: 77952887918     PISSN: 03038467     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clineuro.2010.03.019     Document Type: Article
Times cited : (22)

References (15)
  • 1
    • 0034979308 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopy guided procedures. Part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient
    • Koenig T.R., Mettler F.A., and Wagner L.K. Skin injuries from fluoroscopy guided procedures. Part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient. AJR Am J Roentgenol 177 (2001) 13-20
    • (2001) AJR Am J Roentgenol , vol.177 , pp. 13-20
    • Koenig, T.R.1    Mettler, F.A.2    Wagner, L.K.3
  • 2
    • 56849124126 scopus 로고    scopus 로고
    • Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters
    • Moritake T., Matsumaru Y., Takigawa T., Nishizawa K., Matsumura A., and Tsuboi K. Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters. AJNR Am J Neuroradiol 29 (2008) 1910-1917
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1910-1917
    • Moritake, T.1    Matsumaru, Y.2    Takigawa, T.3    Nishizawa, K.4    Matsumura, A.5    Tsuboi, K.6
  • 3
    • 0027960590 scopus 로고
    • Radiation induced temporary epilation after neuroradiologically guided embolization procedure
    • Huda W., and Peters K.R. Radiation induced temporary epilation after neuroradiologically guided embolization procedure. Radiology 193 (1994) 642-644
    • (1994) Radiology , vol.193 , pp. 642-644
    • Huda, W.1    Peters, K.R.2
  • 5
    • 0032763267 scopus 로고    scopus 로고
    • Temporary hair loss simulating alopecia areata after endovascular surgery of cerebral arteriovenous malformations: a report of 3 cases
    • Antonella T., Bianca Maria P., and Giorgio A. Temporary hair loss simulating alopecia areata after endovascular surgery of cerebral arteriovenous malformations: a report of 3 cases. Arch Dermatol 135 (1999) 1555-1556
    • (1999) Arch Dermatol , vol.135 , pp. 1555-1556
    • Antonella, T.1    Bianca Maria, P.2    Giorgio, A.3
  • 6
    • 0033853364 scopus 로고    scopus 로고
    • Absorbed dose and deterministic effects to patients from interventional neuroradiology
    • Mooney R.B., McKinstry C.S., and Kamel H.A.M. Absorbed dose and deterministic effects to patients from interventional neuroradiology. Br J Radiol 73 (2000) 745-751
    • (2000) Br J Radiol , vol.73 , pp. 745-751
    • Mooney, R.B.1    McKinstry, C.S.2    Kamel, H.A.M.3
  • 7
    • 0037675819 scopus 로고    scopus 로고
    • Radiation-induced temporary alopecia after embolization of cerebral arteriovenous malformations
    • Wen C.S., Lin S.M., Chen Y., Chen J.C., Wang Y.H., and Tseng S.H. Radiation-induced temporary alopecia after embolization of cerebral arteriovenous malformations. Clin Neurol Neurosurg 105 (2003) 215-217
    • (2003) Clin Neurol Neurosurg , vol.105 , pp. 215-217
    • Wen, C.S.1    Lin, S.M.2    Chen, Y.3    Chen, J.C.4    Wang, Y.H.5    Tseng, S.H.6
  • 9
    • 33846119292 scopus 로고    scopus 로고
    • Peculiar geometric alopecia and trigeminal nerve dysfunction in a patient after Guglielmi detachable coil embolization of a ruptured aneurysm
    • Thorat J.D., and Hwang P.Y. Peculiar geometric alopecia and trigeminal nerve dysfunction in a patient after Guglielmi detachable coil embolization of a ruptured aneurysm. J Stroke Cerebrovasc Dis 16 (2007) 40-42
    • (2007) J Stroke Cerebrovasc Dis , vol.16 , pp. 40-42
    • Thorat, J.D.1    Hwang, P.Y.2
  • 10
    • 46749141308 scopus 로고    scopus 로고
    • Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator
    • Suzuki S., Furui S., Matsumaru Y., Sakai N., Ebara M., Abe T., et al. Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator. AJNR Am J Neuroradiol 29 (2008) 1076-1081
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1076-1081
    • Suzuki, S.1    Furui, S.2    Matsumaru, Y.3    Sakai, N.4    Ebara, M.5    Abe, T.6
  • 11
    • 0032823443 scopus 로고    scopus 로고
    • The potential for radiation-induced skin damage in interventional neuroradiological procedures: a review of 522 cases using automated dosimetry
    • O'Dea T.J., Geise R.A., and Ritenour E.R. The potential for radiation-induced skin damage in interventional neuroradiological procedures: a review of 522 cases using automated dosimetry. Med Phys 26 (1999) 2027-2033
    • (1999) Med Phys , vol.26 , pp. 2027-2033
    • O'Dea, T.J.1    Geise, R.A.2    Ritenour, E.R.3
  • 12
    • 0942277191 scopus 로고    scopus 로고
    • Dose measurement for patients and physicians using a glass dosimeter during endovascular treatment for brain disease
    • Nishizawa T., Moritake T., Matsumaru Y., Tsuboi K., and Iwai K. Dose measurement for patients and physicians using a glass dosimeter during endovascular treatment for brain disease. Radiat Prot Dosimetry 107 (2003) 247-252
    • (2003) Radiat Prot Dosimetry , vol.107 , pp. 247-252
    • Nishizawa, T.1    Moritake, T.2    Matsumaru, Y.3    Tsuboi, K.4    Iwai, K.5
  • 13
    • 0034436030 scopus 로고    scopus 로고
    • Avoidance of radiation injuries from medical intervention procedures. ICRP Publication 85
    • International Commission on Radiological Protection. Avoidance of radiation injuries from medical intervention procedures. ICRP Publication 85. Ann ICRP 30 (2000) 7-67
    • (2000) Ann ICRP , vol.30 , pp. 7-67
    • International Commission on Radiological Protection1
  • 15
    • 0038294287 scopus 로고    scopus 로고
    • Radiation doses in interventional radiology procedures: the RAD-IR study. Part II. Skin dose
    • Miller D.L., Balter S., Cole P.E., Lu H.T., Berenstein A., Albert R., et al. Radiation doses in interventional radiology procedures: the RAD-IR study. Part II. Skin dose. J Vasc Interv Radiol 14 (2003) 977-990
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 977-990
    • Miller, D.L.1    Balter, S.2    Cole, P.E.3    Lu, H.T.4    Berenstein, A.5    Albert, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.