-
1
-
-
85047680497
-
Non-invasive measurement of renal blood flow with 99 mTc DTPA: comparison with radiolabelled microspheres
-
Peters A.M., Brown J., Hartnell G.G., Myers M.J., Haskell C., and Lavender J.P. Non-invasive measurement of renal blood flow with 99 mTc DTPA: comparison with radiolabelled microspheres. Cardiovasc Res 21 (1987) 830-834
-
(1987)
Cardiovasc Res
, vol.21
, pp. 830-834
-
-
Peters, A.M.1
Brown, J.2
Hartnell, G.G.3
Myers, M.J.4
Haskell, C.5
Lavender, J.P.6
-
2
-
-
0032969865
-
Consensus report on quality control of quantitative measurement of renal function obtained from the renogram: International Consensus Committee from the Scientific Committee of Radionuclides in Nephrourology
-
Prigent A., Cosgriff P., Gates G.F., et al. Consensus report on quality control of quantitative measurement of renal function obtained from the renogram: International Consensus Committee from the Scientific Committee of Radionuclides in Nephrourology. Semin Nucl Med 24 (1999) 146-159
-
(1999)
Semin Nucl Med
, vol.24
, pp. 146-159
-
-
Prigent, A.1
Cosgriff, P.2
Gates, G.F.3
-
3
-
-
0344153788
-
Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique
-
Hackstein N., Heckrodt J., and Rau W.S. Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique. J Magn Reson Imaging 18 (2003) 714-725
-
(2003)
J Magn Reson Imaging
, vol.18
, pp. 714-725
-
-
Hackstein, N.1
Heckrodt, J.2
Rau, W.S.3
-
4
-
-
0025091134
-
T1 and T2 relaxation times on gadolinium-diethylenetriaminepentaacetic acid enhanced magnetic resonance images of brain tumours
-
Yamada S., Kubota R., Yamada K., et al. T1 and T2 relaxation times on gadolinium-diethylenetriaminepentaacetic acid enhanced magnetic resonance images of brain tumours. Tohoku J Exp Med 160 (1990) 145-148
-
(1990)
Tohoku J Exp Med
, vol.160
, pp. 145-148
-
-
Yamada, S.1
Kubota, R.2
Yamada, K.3
-
5
-
-
0029992602
-
Dynamic Gd-DTPA-enhanced MR imaging of the kidney: comparison between T1- and T2-weighted sequences
-
Tsushima Y., Niemi P., Komu M., et al. Dynamic Gd-DTPA-enhanced MR imaging of the kidney: comparison between T1- and T2-weighted sequences. Am J Nephrol 16 (1996) 506-512
-
(1996)
Am J Nephrol
, vol.16
, pp. 506-512
-
-
Tsushima, Y.1
Niemi, P.2
Komu, M.3
-
6
-
-
69849103545
-
-
IEEE, ICIP, Singapore
-
Sun Y., Jolly M.P., and Moura J.M.F. Integrated registration of dynamic renal perfusion MR images (2004), IEEE, ICIP, Singapore
-
(2004)
Integrated registration of dynamic renal perfusion MR images
-
-
Sun, Y.1
Jolly, M.P.2
Moura, J.M.F.3
-
7
-
-
33748963955
-
Analysis of contrast-enhanced MR images to assess renal function.
-
Michoux N., Vallee J.P., Pechere-Bertschi A., et al. Analysis of contrast-enhanced MR images to assess renal function. MAGMA 19 (2006) 167-179
-
(2006)
MAGMA
, vol.19
, pp. 167-179
-
-
Michoux, N.1
Vallee, J.P.2
Pechere-Bertschi, A.3
-
8
-
-
53549084592
-
Improvement of MRI-Functional measurement with automatic movement correction in native and transplanted kidneys
-
de Senneville B.D., Mendichovszky I., Roujol S., Gordon I., Moonen C., and Grenier N. Improvement of MRI-Functional measurement with automatic movement correction in native and transplanted kidneys. J Magn Reson Imaging 28 (2008) 970-978
-
(2008)
J Magn Reson Imaging
, vol.28
, pp. 970-978
-
-
de Senneville, B.D.1
Mendichovszky, I.2
Roujol, S.3
Gordon, I.4
Moonen, C.5
Grenier, N.6
-
9
-
-
37149023849
-
Measurement of glomerular filtration rate with magnetic resonance imaging: principles, limitations, and expectations
-
Grenier N., Mendichovszky I., de Senneville B.D., et al. Measurement of glomerular filtration rate with magnetic resonance imaging: principles, limitations, and expectations. Semin Nucl Med 38 (2008) 47-55
-
(2008)
Semin Nucl Med
, vol.38
, pp. 47-55
-
-
Grenier, N.1
Mendichovszky, I.2
de Senneville, B.D.3
-
10
-
-
41949136504
-
How accurate is dynamic contrast-enhanced MRI in the assessment of renal glomerular filtration rate? A critical appraisal
-
Mendichovszky I., Pedersen M., Frokiaer J., et al. How accurate is dynamic contrast-enhanced MRI in the assessment of renal glomerular filtration rate? A critical appraisal. J Magn Reson Imaging 27 (2008) 925-931
-
(2008)
J Magn Reson Imaging
, vol.27
, pp. 925-931
-
-
Mendichovszky, I.1
Pedersen, M.2
Frokiaer, J.3
-
11
-
-
7044231811
-
1-weighted dynamic contrast-enhanced MRI
-
Tofts P. (Ed), John Wiley & Sons Ltd., Chichester
-
1-weighted dynamic contrast-enhanced MRI. In: Tofts P. (Ed). Quantitative MRI of the brain (2003), John Wiley & Sons Ltd., Chichester 341
-
(2003)
Quantitative MRI of the brain
, pp. 341
-
-
Parker, G.J.M.1
Padhani, A.R.2
-
12
-
-
69849099312
-
Reproducibility of the aortic input function (AIF) derived from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study
-
10.1016/j.ejrad.2008.09.025
-
Mendichovszky I.A., Cutajar M., and Gordon I. Reproducibility of the aortic input function (AIF) derived from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of the kidneys in a volunteer study. Eur J Radiol (2008) 10.1016/j.ejrad.2008.09.025
-
(2008)
Eur J Radiol
-
-
Mendichovszky, I.A.1
Cutajar, M.2
Gordon, I.3
-
13
-
-
0020956774
-
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
-
Patlak C.S., Blasberg R.G., and Fenstermacher J.D. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 3 (1983) 1-7
-
(1983)
J Cereb Blood Flow Metab
, vol.3
, pp. 1-7
-
-
Patlak, C.S.1
Blasberg, R.G.2
Fenstermacher, J.D.3
-
14
-
-
24744450987
-
Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA
-
Hackstein N., Kooijman H., Tomaselli S., and Rau W.S. Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA. J Magn Reson Imaging 22 (2005) 406-414
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 406-414
-
-
Hackstein, N.1
Kooijman, H.2
Tomaselli, S.3
Rau, W.S.4
-
15
-
-
7044269262
-
Glomerular filtration rate: assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney
-
Annet L., Hermoye L., Peeters F., et al. Glomerular filtration rate: assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney. J Magn Reson Imaging 20 (2004) 843-849
-
(2004)
J Magn Reson Imaging
, vol.20
, pp. 843-849
-
-
Annet, L.1
Hermoye, L.2
Peeters, F.3
-
16
-
-
33750442900
-
Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects
-
Buckley D.L., Shurrab A.E., Cheung C.M., et al. Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects. J Magn Reson Imaging 24 (2006) 1117-1123
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 1117-1123
-
-
Buckley, D.L.1
Shurrab, A.E.2
Cheung, C.M.3
-
17
-
-
34247862083
-
Renal function measurements from MR renography and a simplified multicompartmental model
-
Lee V.S., Rusinek H., Bokacheva L., et al. Renal function measurements from MR renography and a simplified multicompartmental model. Am J Physiol Renal Physiol 292 (2007) F1548-F1559
-
(2007)
Am J Physiol Renal Physiol
, vol.292
-
-
Lee, V.S.1
Rusinek, H.2
Bokacheva, L.3
-
18
-
-
37549034234
-
MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model
-
Sourbron S.P., Michaely H.J., Reiser M.F., and Schoenberg S.O. MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model. Invest Radiol 43 (2008) 40-48
-
(2008)
Invest Radiol
, vol.43
, pp. 40-48
-
-
Sourbron, S.P.1
Michaely, H.J.2
Reiser, M.F.3
Schoenberg, S.O.4
-
20
-
-
77952882112
-
A simple three-compartment model that describes Dynamic Contrast-Enhanced MRI signal in the kidney cortex
-
Valencia 10.1007/s10334-008-0123-5
-
Tofts P.S., Mendichovszky I.A., Buckley I.A., et al. A simple three-compartment model that describes Dynamic Contrast-Enhanced MRI signal in the kidney cortex. ESMRMB 2008 Congress. Valencia (2008) 10.1007/s10334-008-0123-5
-
(2008)
ESMRMB 2008 Congress
-
-
Tofts, P.S.1
Mendichovszky, I.A.2
Buckley, I.A.3
-
21
-
-
77952883751
-
Estimating GFR from early (uptake) portion of DEC-MRI renal data, using a 3-compartment model, improves reproducibility and may eliminate need for cortical segmentation.
-
Hawaii
-
Tofts P.S., Cutajar M., Mendichovszky I.A., and Gordon I. Estimating GFR from early (uptake) portion of DEC-MRI renal data, using a 3-compartment model, improves reproducibility and may eliminate need for cortical segmentation. ISMRM 17th Scientific Meeting & Exhibition abstract number 1503. Hawaii (2009)
-
(2009)
ISMRM 17th Scientific Meeting & Exhibition abstract number 1503
-
-
Tofts, P.S.1
Cutajar, M.2
Mendichovszky, I.A.3
Gordon, I.4
-
22
-
-
44449148370
-
Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects
-
Bird N.J., Peters C., Michell A.R., and Peters A.M. Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects. Nephrol Dial Transplant 23 6 (2008) 1902-1909
-
(2008)
Nephrol Dial Transplant
, vol.23
, Issue.6
, pp. 1902-1909
-
-
Bird, N.J.1
Peters, C.2
Michell, A.R.3
Peters, A.M.4
|