-
1
-
-
0033753104
-
Cardiac imaging by means of electrocardiographically gated multisection spiral CT initial experience
-
Ohnesorge B., Flohr T., Becker C., et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT initial experience. Radiology 217 (2000) 564-571
-
(2000)
Radiology
, vol.217
, pp. 564-571
-
-
Ohnesorge, B.1
Flohr, T.2
Becker, C.3
-
2
-
-
0033863629
-
ECG-correlated image reconstruction from subsecond multislice spiral CT scans of the heart
-
Kachelriess M., Ulzheimer S., and Kalender W. ECG-correlated image reconstruction from subsecond multislice spiral CT scans of the heart. Med Phys 27 (2000) 1881-1902
-
(2000)
Med Phys
, vol.27
, pp. 1881-1902
-
-
Kachelriess, M.1
Ulzheimer, S.2
Kalender, W.3
-
3
-
-
0034117652
-
High temporal resolution for multi slice helical computed tomography
-
Taguchi K., and Anno H. High temporal resolution for multi slice helical computed tomography. Med Phys 27 (2000) 861-872
-
(2000)
Med Phys
, vol.27
, pp. 861-872
-
-
Taguchi, K.1
Anno, H.2
-
4
-
-
0034867726
-
ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality
-
Hong C., Becker C., Huber A., et al. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220 (2001) 712-717
-
(2001)
Radiology
, vol.220
, pp. 712-717
-
-
Hong, C.1
Becker, C.2
Huber, A.3
-
5
-
-
0035191747
-
Coronary arteries: retrospective ECG-gated multidetector row CT angiography with selective optimization of the image reconstruction window
-
Kopp A., Schröder S., Küttner A., et al. Coronary arteries: retrospective ECG-gated multidetector row CT angiography with selective optimization of the image reconstruction window. Radiology 221 (2001) 683-688
-
(2001)
Radiology
, vol.221
, pp. 683-688
-
-
Kopp, A.1
Schröder, S.2
Küttner, A.3
-
6
-
-
0036373605
-
New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
-
Flohr T., Bruder H., Stierstorfer K., Simon J., Schaller S., and Ohnesorge B. New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. RÖFO 174 (2002) 1022-1027
-
(2002)
RÖFO
, vol.174
, pp. 1022-1027
-
-
Flohr, T.1
Bruder, H.2
Stierstorfer, K.3
Simon, J.4
Schaller, S.5
Ohnesorge, B.6
-
7
-
-
0242585341
-
Advances in cardiac imaging with 16-section CT-systems
-
Flohr T., Schoepf U.J., Kuettner A., et al. Advances in cardiac imaging with 16-section CT-systems. Acad Radiol 10 (2003) 386-401
-
(2003)
Acad Radiol
, vol.10
, pp. 386-401
-
-
Flohr, T.1
Schoepf, U.J.2
Kuettner, A.3
-
8
-
-
33645749654
-
Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates
-
Hausleiter J., Meyer T., Hadamitzky M., et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113 (2006) 1305-1310
-
(2006)
Circulation
, vol.113
, pp. 1305-1310
-
-
Hausleiter, J.1
Meyer, T.2
Hadamitzky, M.3
-
9
-
-
33745015635
-
Image quality, motion artifacts, and reconstruction timing of a 64-slice coronary computed tomography angiography with 0.33 second rotation speed
-
Wintersperger B.J., Nikolaou K., Ziegler F.V., et al. Image quality, motion artifacts, and reconstruction timing of a 64-slice coronary computed tomography angiography with 0.33 second rotation speed. Invest Radiol 41 (2006) 436-442
-
(2006)
Invest Radiol
, vol.41
, pp. 436-442
-
-
Wintersperger, B.J.1
Nikolaou, K.2
Ziegler, F.V.3
-
10
-
-
31444454089
-
First performance evaluation of a dual-source CT (DSCT) system
-
Flohr T., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
-
(2006)
Eur Radiol
, vol.16
, pp. 256-268
-
-
Flohr, T.1
McCollough, C.H.2
Bruder, H.3
-
11
-
-
33745024717
-
Dual source CT cardiac imaging: initial experience
-
Johnson T.R., Nikolaou K., Wintersperger B.J., et al. Dual source CT cardiac imaging: initial experience. Eur Radiol 16 (2006) 1409-1415
-
(2006)
Eur Radiol
, vol.16
, pp. 1409-1415
-
-
Johnson, T.R.1
Nikolaou, K.2
Wintersperger, B.J.3
-
12
-
-
32844464236
-
Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience
-
Achenbach S., Rupers D., Kuettner D., et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur Radiol 57 (2006) 331-335
-
(2006)
Eur Radiol
, vol.57
, pp. 331-335
-
-
Achenbach, S.1
Rupers, D.2
Kuettner, D.3
-
13
-
-
34249023378
-
Dose performance of a 64-channel dual-source CT scanner
-
McCollough C., Primak A., Saba O., et al. Dose performance of a 64-channel dual-source CT scanner. Radiology 243 (2007) 775-784
-
(2007)
Radiology
, vol.243
, pp. 775-784
-
-
McCollough, C.1
Primak, A.2
Saba, O.3
-
14
-
-
10344230948
-
Performance evaluation of a 64-slice CT-system with z-flying focal spot
-
Flohr T., Stierstorfer K., Raupach R., Ulzheimer S., and Bruder H. Performance evaluation of a 64-slice CT-system with z-flying focal spot. RÖFO 176 (2004) 1803-1810
-
(2004)
RÖFO
, vol.176
, pp. 1803-1810
-
-
Flohr, T.1
Stierstorfer, K.2
Raupach, R.3
Ulzheimer, S.4
Bruder, H.5
-
15
-
-
23944513257
-
Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
-
Flohr T.G., Stierstorfer K., Ulzheimer S., Bruder H., Primak A.N., and McCollough C.H. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med Phys 32 (2005) 2536-2547
-
(2005)
Med Phys
, vol.32
, pp. 2536-2547
-
-
Flohr, T.G.1
Stierstorfer, K.2
Ulzheimer, S.3
Bruder, H.4
Primak, A.N.5
McCollough, C.H.6
-
16
-
-
31444454089
-
First performance evaluation of a dual-source CT system
-
Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT system. Eur Radiol 16 (2006) 256-268
-
(2006)
Eur Radiol
, vol.16
, pp. 256-268
-
-
Flohr, T.G.1
McCollough, C.H.2
Bruder, H.3
-
17
-
-
77952881292
-
-
§1020.33 b 1 Food and Drug administration HHS, FR 26404 May 3 1993 as amended at 59 FR 26404 May 19 1994; 21 CFR Chapter I (4-1-03 Edition), 621-4.
-
§1020.33 b 1) Food and Drug administration HHS, FR 26404 May 3 1993 as amended at 59 FR 26404 May 19 1994; 21 CFR Chapter I (4-1-03 Edition), 621-4.
-
-
-
-
18
-
-
34447338023
-
Image quality and reconstruction intervals of dual source CT coronary angiography recommendations for ECG-pulsing windowing
-
Leschka S., Scheffel H., Desbiolles L., et al. Image quality and reconstruction intervals of dual source CT coronary angiography recommendations for ECG-pulsing windowing. Invest Radiol 42 (2007) 543-549
-
(2007)
Invest Radiol
, vol.42
, pp. 543-549
-
-
Leschka, S.1
Scheffel, H.2
Desbiolles, L.3
-
19
-
-
39049158286
-
Radiation dose estimates in dual-source computed tomography coronary angiography
-
Stolzmann P., Scheffel H., Schertler T., et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18 (2008) 592-599
-
(2008)
Eur Radiol
, vol.18
, pp. 592-599
-
-
Stolzmann, P.1
Scheffel, H.2
Schertler, T.3
-
20
-
-
21044457382
-
Fluoroscopy time-an overestimated factor for patient radiation exposure in invasive cardiology
-
Kuon E., Robinson D.M., Empen K., and Dahm J.B. Fluoroscopy time-an overestimated factor for patient radiation exposure in invasive cardiology. RÖFO 177 (2007) 812-817
-
(2007)
RÖFO
, vol.177
, pp. 812-817
-
-
Kuon, E.1
Robinson, D.M.2
Empen, K.3
Dahm, J.B.4
-
21
-
-
33646201890
-
Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography
-
Coles D.R., Smail M.A., Negus I.S., et al. Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Colloid Cardiol 47 (2007) 1840-1845
-
(2007)
J Am Colloid Cardiol
, vol.47
, pp. 1840-1845
-
-
Coles, D.R.1
Smail, M.A.2
Negus, I.S.3
-
22
-
-
34447558140
-
Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
-
Einstein A.J., Henzlova M.J., and Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298 (2007) 317-323
-
(2007)
JAMA
, vol.298
, pp. 317-323
-
-
Einstein, A.J.1
Henzlova, M.J.2
Rajagopalan, S.3
|