메뉴 건너뛰기




Volumn 71, Issue 7, 2010, Pages 1194-1199

An evaluation of risk factors for inadequate cytology in EUS-guided FNA of pancreatic tumors and lymph nodes

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASPIRATION BIOPSY; COHORT ANALYSIS; CONTROLLED STUDY; CYTOLOGY; DIAGNOSTIC ACCURACY; ENDOSCOPIC ECHOGRAPHY; HISTOPATHOLOGY; HUMAN; HUMAN CELL; HUMAN TISSUE; LYMPHADENOPATHY; MAJOR CLINICAL STUDY; MEDICAL SPECIALIST; NEEDLE; PANCREAS CANCER; PANCREAS TUMOR; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RISK ASSESSMENT; RISK FACTOR; COMPARATIVE STUDY; DIAGNOSTIC ERROR; ECHOGRAPHY; FINE NEEDLE ASPIRATION BIOPSY; FOLLOW UP; LYMPH NODE; LYMPH NODE METASTASIS; PATHOLOGY; PROCEDURES; REPRODUCIBILITY; SECONDARY; STANDARDS;

EID: 77952851069     PISSN: 00165107     EISSN: 10976779     Source Type: Journal    
DOI: 10.1016/j.gie.2010.01.029     Document Type: Article
Times cited : (59)

References (17)
  • 1
    • 32044462317 scopus 로고    scopus 로고
    • Review of endoscopic ultrasound-guided fine-needle aspiration cytology
    • Bardales R.H., Stelow E.B., Mallery S., et al. Review of endoscopic ultrasound-guided fine-needle aspiration cytology. Diagn Cytopathol 34 (2006) 140-175
    • (2006) Diagn Cytopathol , vol.34 , pp. 140-175
    • Bardales, R.H.1    Stelow, E.B.2    Mallery, S.3
  • 2
    • 34447504769 scopus 로고    scopus 로고
    • EUS-guided FNA diagnostic yield of malignancy in solid pancreatic masses: a benchmark for quality performance measurement
    • Savides T.J., Donohue M., Hunt G., et al. EUS-guided FNA diagnostic yield of malignancy in solid pancreatic masses: a benchmark for quality performance measurement. Gastrointest Endosc 66 (2007) 277-282
    • (2007) Gastrointest Endosc , vol.66 , pp. 277-282
    • Savides, T.J.1    Donohue, M.2    Hunt, G.3
  • 3
    • 34248659659 scopus 로고    scopus 로고
    • Can endosonographers evaluate on-site cytologic adequacy?. A comparison with cytotechnologists
    • Savoy A.D., Raimondo M., Woodward T.A., et al. Can endosonographers evaluate on-site cytologic adequacy?. A comparison with cytotechnologists. Gastrointest Endosc 65 (2007) 953-957
    • (2007) Gastrointest Endosc , vol.65 , pp. 953-957
    • Savoy, A.D.1    Raimondo, M.2    Woodward, T.A.3
  • 4
    • 0035916923 scopus 로고    scopus 로고
    • Endoscopic ultrasonography-guided fine-needle aspiration biopsy of suspected pancreatic cancer
    • Gress F., Gottlieb K., Sherman S., et al. Endoscopic ultrasonography-guided fine-needle aspiration biopsy of suspected pancreatic cancer. Ann Intern Med 134 (2001) 459-464
    • (2001) Ann Intern Med , vol.134 , pp. 459-464
    • Gress, F.1    Gottlieb, K.2    Sherman, S.3
  • 5
    • 0036088045 scopus 로고    scopus 로고
    • Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses
    • Harewood G.C., and Wiersema M.J. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses. Am J Gastroenterol 97 (2002) 1386-1391
    • (2002) Am J Gastroenterol , vol.97 , pp. 1386-1391
    • Harewood, G.C.1    Wiersema, M.J.2
  • 6
    • 0347994968 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: diagnostic accuracy and acute and 30-day complications
    • Eloubeidi M.A., Chen V.K., Eltoum I.A., et al. Endoscopic ultrasound-guided fine needle aspiration biopsy of patients with suspected pancreatic cancer: diagnostic accuracy and acute and 30-day complications. Am J Gastroenterol 98 (2003) 2663-2668
    • (2003) Am J Gastroenterol , vol.98 , pp. 2663-2668
    • Eloubeidi, M.A.1    Chen, V.K.2    Eltoum, I.A.3
  • 7
    • 0038702434 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration of the pancreas. Diagnostic utility and accuracy
    • Afify A.M., al-Khafaji B.M., Kim B., et al. Endoscopic ultrasound-guided fine needle aspiration of the pancreas. Diagnostic utility and accuracy. Acta Cytol 47 (2003) 341-348
    • (2003) Acta Cytol , vol.47 , pp. 341-348
    • Afify, A.M.1    al-Khafaji, B.M.2    Kim, B.3
  • 8
    • 2942679618 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration and multidetector spiral CT in the diagnosis of pancreatic cancer
    • Agarwal B., Abu-Hamda E., Molke K.L., et al. Endoscopic ultrasound-guided fine needle aspiration and multidetector spiral CT in the diagnosis of pancreatic cancer. Am J Gastroenterol 99 (2004) 844-850
    • (2004) Am J Gastroenterol , vol.99 , pp. 844-850
    • Agarwal, B.1    Abu-Hamda, E.2    Molke, K.L.3
  • 9
    • 33646838814 scopus 로고    scopus 로고
    • A randomized comparison of EUS-guided FNA versus CT or US-guided FNA for the evaluation of pancreatic mass lesions
    • Horwhat J.D., Paulson E.K., McGrath K., et al. A randomized comparison of EUS-guided FNA versus CT or US-guided FNA for the evaluation of pancreatic mass lesions. Gastrointest Endosc 63 (2006) 966-975
    • (2006) Gastrointest Endosc , vol.63 , pp. 966-975
    • Horwhat, J.D.1    Paulson, E.K.2    McGrath, K.3
  • 10
    • 0038310881 scopus 로고    scopus 로고
    • Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration
    • Klapman J.B., Logrono R., Dye C.E., et al. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol 98 (2003) 1289-1294
    • (2003) Am J Gastroenterol , vol.98 , pp. 1289-1294
    • Klapman, J.B.1    Logrono, R.2    Dye, C.E.3
  • 11
    • 20244387373 scopus 로고    scopus 로고
    • Maximizing the yield of EUS-guided fine-needle aspiration
    • Chang K.J. Maximizing the yield of EUS-guided fine-needle aspiration. Gastrointest Endosc 56 (2002) S28-S34
    • (2002) Gastrointest Endosc , vol.56
    • Chang, K.J.1
  • 12
    • 0037944084 scopus 로고    scopus 로고
    • Clinical usefulness of KRAS mutational analysis in the diagnosis of pancreatic adenocarcinoma by means of endosonography-guided fine-needle aspiration biopsy
    • Pellise M., Castells A., Gines A., et al. Clinical usefulness of KRAS mutational analysis in the diagnosis of pancreatic adenocarcinoma by means of endosonography-guided fine-needle aspiration biopsy. Aliment Pharmacol Ther 17 (2003) 1299-1307
    • (2003) Aliment Pharmacol Ther , vol.17 , pp. 1299-1307
    • Pellise, M.1    Castells, A.2    Gines, A.3
  • 13
    • 0035986965 scopus 로고    scopus 로고
    • Diagnostic value and cost-effectiveness of on-site evaluation of fine-needle aspiration specimens: review of 5,688 cases
    • Nasuti J.F., Gupta P.K., and Baloch Z.W. Diagnostic value and cost-effectiveness of on-site evaluation of fine-needle aspiration specimens: review of 5,688 cases. Diagn Cytopathol 27 (2002) 1-4
    • (2002) Diagn Cytopathol , vol.27 , pp. 1-4
    • Nasuti, J.F.1    Gupta, P.K.2    Baloch, Z.W.3
  • 14
    • 12144288869 scopus 로고    scopus 로고
    • Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis
    • LeBlanc J.K., Ciaccia D., Al-Assi M.T., et al. Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis. Gastrointest Endosc 59 (2004) 475-481
    • (2004) Gastrointest Endosc , vol.59 , pp. 475-481
    • LeBlanc, J.K.1    Ciaccia, D.2    Al-Assi, M.T.3
  • 15
    • 0033980883 scopus 로고    scopus 로고
    • Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies
    • Erickson R.A., Sayage-Rabie L., and Beissner R.S. Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 51 (2000) 184-190
    • (2000) Gastrointest Endosc , vol.51 , pp. 184-190
    • Erickson, R.A.1    Sayage-Rabie, L.2    Beissner, R.S.3
  • 16
    • 34548552953 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration: predictive factors of accurate diagnosis and cost-minimization analysis of on-site pathologist
    • Pellise Urquiza M., Fernandez-Esparrach G., Sole M., et al. Endoscopic ultrasound-guided fine needle aspiration: predictive factors of accurate diagnosis and cost-minimization analysis of on-site pathologist. Gastroenterol Hepatol 30 (2007) 319-324
    • (2007) Gastroenterol Hepatol , vol.30 , pp. 319-324
    • Pellise Urquiza, M.1    Fernandez-Esparrach, G.2    Sole, M.3
  • 17
    • 0035486763 scopus 로고    scopus 로고
    • Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy
    • Wallace M.B., Kennedy T., Durkalski V., et al. Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy. Gastrointest Endosc 54 (2001) 441-447
    • (2001) Gastrointest Endosc , vol.54 , pp. 441-447
    • Wallace, M.B.1    Kennedy, T.2    Durkalski, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.