메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2429-2432

Robust motion estimation using complex principal components

Author keywords

Elastography; Motion estimation; Principal component analysis

Indexed keywords

MEDICAL IMAGING; MOTION ESTIMATION;

EID: 77952816208     PISSN: 10510117     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ULTSYM.2009.5441867     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 1
    • 0000474501 scopus 로고
    • Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities-Part II: Effects of and correction for motion
    • L Nock and G Trahey, "Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities-Part II: Effects of and correction for motion," IEEE Trans Ultrason Ferroelect Freq Contr, vol. 39, pp. 496-501, 1992.
    • (1992) IEEE Trans Ultrason Ferroelect Freq Contr , vol.39 , pp. 496-501
    • Nock, L.1    Trahey, G.2
  • 3
    • 84939739865 scopus 로고
    • Real-time two-dimensional blood flow imaging using autocorrelation technique
    • C Kasai, K Namekawa, A Koyano, R Omoto, "Real-time two-dimensional blood flow imaging using autocorrelation technique," IEEE Trans Sonics Ultrason, vol. 32, pp. 458-463, 1985.
    • (1985) IEEE Trans Sonics Ultrason , vol.32 , pp. 458-463
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4
  • 4
    • 0029344834 scopus 로고
    • An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach
    • T Loupas, R Peterson, and R Gill, "An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach," IEEE Trans Ultrason Ferroelect Freq Contr, vol. 42, pp. 672-688, 1995.
    • (1995) IEEE Trans Ultrason Ferroelect Freq Contr , vol.42 , pp. 672-688
    • Loupas, T.1    Peterson, R.2    Gill, R.3
  • 5
    • 13844253845 scopus 로고    scopus 로고
    • A spline-based algorithm for continuous time-delay estimation using sampled data
    • F Viola and W Walker, "A spline-based algorithm for continuous time-delay estimation using sampled data," IEEE Trans Ultrason Ferroelect Freq Contr, vol. 52, pp. 80-93, 2005.
    • (2005) IEEE Trans Ultrason Ferroelect Freq Contr , vol.52 , pp. 80-93
    • Viola, F.1    Walker, W.2
  • 6
    • 67650266274 scopus 로고    scopus 로고
    • Reduction of echo decorrelation via complex principal component filtering
    • F Mauldin, F Viola, W Walker, "Reduction of echo decorrelation via complex principal component filtering," Ultrasound in Med and Biol, vol. 35, pp. 1325-1343, 2009.
    • (2009) Ultrasound in Med and Biol , vol.35 , pp. 1325-1343
    • Mauldin, F.1    Viola, F.2    Walker, W.3
  • 9
    • 57049160927 scopus 로고    scopus 로고
    • The general properties including accuracy and resolution of linear filtering methods for strain estimation
    • J Lindop, G Treece, A Gee, R Prager, "The general properties including accuracy and resolution of linear filtering methods for strain estimation," IEEE Trans Ultrason Ferroelect Freq Contr., vol. 55, pp. 2363-2368, 2008.
    • (2008) IEEE Trans Ultrason Ferroelect Freq Contr. , vol.55 , pp. 2363-2368
    • Lindop, J.1    Treece, G.2    Gee, A.3    Prager, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.