메뉴 건너뛰기




Volumn 37, Issue 6, 2010, Pages 1317-1321

Modified bio-Bentall procedure: 10-year experience

Author keywords

Aortic valve; Ascending aorta; Biological valve prosthesis; Valve composite graft

Indexed keywords

ADULT; AGED; ANEURYSM; AORTA INJURY; AORTA VALVE REPLACEMENT; AORTIC ROOT SURGERY; ARTICLE; BLOOD TRANSFUSION; BLOOD VESSEL GRAFT; COMPOSITE GRAFT; CORONARY SINUS; DISSECTION; ENDOCARDITIS; FEMALE; FOLLOW UP; HEART VALVE BIOPROSTHESIS; HOSPITALIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; OVERALL SURVIVAL; POSTOPERATIVE HEMORRHAGE; PRIORITY JOURNAL; PROSPECTIVE STUDY; REOPERATION; SURGICAL TECHNIQUE; THORACOTOMY; TREATMENT INDICATION;

EID: 77952583847     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2009.12.017     Document Type: Article
Times cited : (24)

References (25)
  • 1
    • 0014311521 scopus 로고
    • A technique for complete replacement of the ascending aorta
    • Bentall H., and De Bono A. A technique for complete replacement of the ascending aorta. Thorax 23 (1968) 338-339
    • (1968) Thorax , vol.23 , pp. 338-339
    • Bentall, H.1    De Bono, A.2
  • 2
    • 0002664842 scopus 로고    scopus 로고
    • Proximal aortic dissection
    • Borst H.G., Heinemann M.K., and Stone S.D. (Eds), Churchill Livingstone, New York
    • Borst H.G., Heinemann M.K., and Stone C.D. Proximal aortic dissection. In: Borst H.G., Heinemann M.K., and Stone S.D. (Eds). Surgical treatment of aortic dissection (1996), Churchill Livingstone, New York 123-202
    • (1996) Surgical treatment of aortic dissection , pp. 123-202
    • Borst, H.G.1    Heinemann, M.K.2    Stone, C.D.3
  • 4
    • 0033035766 scopus 로고    scopus 로고
    • Replacement of the ascending aorta and aortic valve with a valved stentless composite graft
    • Urbanski P.P. Replacement of the ascending aorta and aortic valve with a valved stentless composite graft. Ann Thorac Surg 67 (1999) 1501-1502
    • (1999) Ann Thorac Surg , vol.67 , pp. 1501-1502
    • Urbanski, P.P.1
  • 5
    • 0033943970 scopus 로고    scopus 로고
    • Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: technical considerations and early clinical results
    • Urbanski P.P., and Hacker W. Replacement of the aortic valve and ascending aorta with a valved stentless composite graft: technical considerations and early clinical results. Ann Thorac Surg 70 (2000) 17-20
    • (2000) Ann Thorac Surg , vol.70 , pp. 17-20
    • Urbanski, P.P.1    Hacker, W.2
  • 6
    • 35348876106 scopus 로고    scopus 로고
    • New vascular graft for assembling the stentless valve composite graft
    • Urbanski P.P. New vascular graft for assembling the stentless valve composite graft. Ann Thorac Surg 84 (2007) 1771-1773
    • (2007) Ann Thorac Surg , vol.84 , pp. 1771-1773
    • Urbanski, P.P.1
  • 7
    • 0023033299 scopus 로고
    • Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve
    • Kouchoukos N.T., Marshall Jr. W.G., and Wedige-Stecher T.A. Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve. J Thorac Cardiovasc Surg 92 (1986) 691-705
    • (1986) J Thorac Cardiovasc Surg , vol.92 , pp. 691-705
    • Kouchoukos, N.T.1    Marshall Jr., W.G.2    Wedige-Stecher, T.A.3
  • 10
    • 58249086539 scopus 로고    scopus 로고
    • Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database
    • Brown J.M., O'Brien S.M., Wu C., Sikora J.A.H., Griffith B.P., and Gammie J.S. Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database. J Thorac Cardiovasc Surg 137 (2009) 82-90
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 82-90
    • Brown, J.M.1    O'Brien, S.M.2    Wu, C.3    Sikora, J.A.H.4    Griffith, B.P.5    Gammie, J.S.6
  • 11
    • 0033001760 scopus 로고    scopus 로고
    • Aortic and pulmonary autografts for replacement of the aortic valve and aortic root
    • Kouchoukos N.T. Aortic and pulmonary autografts for replacement of the aortic valve and aortic root. Ann Thorac Surg 67 (1999) 1846-1848
    • (1999) Ann Thorac Surg , vol.67 , pp. 1846-1848
    • Kouchoukos, N.T.1
  • 14
    • 33644592013 scopus 로고    scopus 로고
    • Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta
    • Kirsch E.W.M., Radu N.C., Mekontso-Dessap A., Hillion M.L., and Loisance D. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta. J Thorac Cardiovasc Surg 131 (2006) 601-608
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 601-608
    • Kirsch, E.W.M.1    Radu, N.C.2    Mekontso-Dessap, A.3    Hillion, M.L.4    Loisance, D.5
  • 15
    • 58249135349 scopus 로고    scopus 로고
    • Postimplantation morphologic changes of glutaraldehyde-fixed porcine aortic roots and risk of aneurysm and rupture
    • David T.E., Armstrong S., Maganti M., Butany J., Feindel C.M., and Bos J. Postimplantation morphologic changes of glutaraldehyde-fixed porcine aortic roots and risk of aneurysm and rupture. J Thorac Cardiovasc Surg 137 (2009) 94-100
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 94-100
    • David, T.E.1    Armstrong, S.2    Maganti, M.3    Butany, J.4    Feindel, C.M.5    Bos, J.6
  • 16
    • 21744457063 scopus 로고    scopus 로고
    • Giant pseudoaneurysm after proximal aortic surgery treated by means of redo axillary artery cannulation and use of an endoclamp device
    • Dagenais F., Voisine P., and Mathieu P. Giant pseudoaneurysm after proximal aortic surgery treated by means of redo axillary artery cannulation and use of an endoclamp device. J Thorac Cardiovasc Surg 130 (2005) 208-209
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 208-209
    • Dagenais, F.1    Voisine, P.2    Mathieu, P.3
  • 17
    • 0036189077 scopus 로고    scopus 로고
    • Complete aortic root replacement in patients with small aortic annulus
    • Urbanski P.P. Complete aortic root replacement in patients with small aortic annulus. Ann Thorac Surg 73 (2002) 725-729
    • (2002) Ann Thorac Surg , vol.73 , pp. 725-729
    • Urbanski, P.P.1
  • 19
    • 0037317192 scopus 로고    scopus 로고
    • Valved stentless composite graft: clinical outcomes and hemodynamic characteristics
    • Urbanski P.P., Diegeler A., Siebel A., Zacher M., and Hacker R.W. Valved stentless composite graft: clinical outcomes and hemodynamic characteristics. Ann Thorac Surg 75 (2003) 467-471
    • (2003) Ann Thorac Surg , vol.75 , pp. 467-471
    • Urbanski, P.P.1    Diegeler, A.2    Siebel, A.3    Zacher, M.4    Hacker, R.W.5
  • 21
    • 71649090090 scopus 로고    scopus 로고
    • Replacement of valve prosthesis within aortic composite graft
    • Urbanski P.P. Replacement of valve prosthesis within aortic composite graft. Ann Thorac Surg 88 (2009) 2024-2025
    • (2009) Ann Thorac Surg , vol.88 , pp. 2024-2025
    • Urbanski, P.P.1
  • 22
    • 0032076078 scopus 로고    scopus 로고
    • Stentless xenograft repair of the dissected aortic root
    • Westaby S., Katsumata T., Houel R., and Shinfeld A. Stentless xenograft repair of the dissected aortic root. Ann Thorac Surg 65 (1998) 1448-1450
    • (1998) Ann Thorac Surg , vol.65 , pp. 1448-1450
    • Westaby, S.1    Katsumata, T.2    Houel, R.3    Shinfeld, A.4
  • 24
    • 0035654277 scopus 로고    scopus 로고
    • The use of composite stentless valves with graft extension for the treatment of ascending aortic aneurysms
    • Akpinar B., and Guden M. The use of composite stentless valves with graft extension for the treatment of ascending aortic aneurysms. Eur J Cardiothorac Surg 20 (2001) 1278-1279
    • (2001) Eur J Cardiothorac Surg , vol.20 , pp. 1278-1279
    • Akpinar, B.1    Guden, M.2
  • 25
    • 37549013696 scopus 로고    scopus 로고
    • Aortic valve replacement with Toronto SPV bioprosthesis: optimal patient survival but suboptimal valve durability
    • David T.E., Feindel C.M., Bos J., Ivanov J., and Armstrong S. Aortic valve replacement with Toronto SPV bioprosthesis: optimal patient survival but suboptimal valve durability. J Thorac Cardiovasc Surg 135 (2008) 19-24
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 19-24
    • David, T.E.1    Feindel, C.M.2    Bos, J.3    Ivanov, J.4    Armstrong, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.