메뉴 건너뛰기




Volumn , Issue , 2009, Pages

Maximum power point tracking parameter selection for higher order converters used in photovoltaic applications

Author keywords

Higher order converter; Maximum power point tracking; Photovoltaic array

Indexed keywords

BUCK CONVERTERS; FOURTH ORDER; HIGHER ORDER; MAXIMUM POWER; MAXIMUM POWER POINT TRACKER; MAXIMUM POWER POINT TRACKING; NON-LINEAR; PARAMETER SELECTION; PARAMETERS SELECTION; PHOTOVOLTAIC APPLICATIONS; PHOTOVOLTAIC ARRAYS; PHOTOVOLTAIC POWER; POWER TRACKING;

EID: 77952565021     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICPWS.2009.5442702     Document Type: Conference Paper
Times cited : (2)

References (19)
  • 2
    • 0031331571 scopus 로고    scopus 로고
    • Integrated photovoltaic maximum power point tracking converter
    • Enslin, J.H.R, Wolf. M.S, Snyman. D.B, Swiegers. W,"Integrated photovoltaic maximum power point tracking converter", IEEE Trans.Ind. Electron, 1997, Vol.44 (6), pp. 769-773.
    • (1997) IEEE Trans.Ind. Electron , vol.44 , Issue.6 , pp. 769-773
    • Enslin, J.H.R.1    Wolf, M.S.2    Snyman, D.B.3    Swiegers, W.4
  • 3
    • 0032000579 scopus 로고    scopus 로고
    • Implementation of a DSP-controlled photovoltaic system with peak power tracking
    • PII S027800469800896X
    • C. Hua, J. Lin, and C. Shen, ́Implementation of a DSP-controlled photovoltaic system with peak power trackinǵ, IEEE Trans. Ind. Electron., 1998, Vol.45(1), pp. 99-107. (Pubitemid 128739744)
    • (1998) IEEE Transactions on Industrial Electronics , vol.45 , Issue.1 , pp. 99-107
    • Hua, C.1    Lin, J.2    Shen, C.3
  • 5
    • 34249794869 scopus 로고    scopus 로고
    • Comparison of photovoltaic array maximum power point tracking techniques
    • DOI 10.1109/TEC.2006.874230
    • T. Esram, P. L. Chapman, ́ Comparison of photovoltaic array maximum power point tracking techniques ́, IEEE Trans. On Energy Conversion, 2007, Vol.22(2), pp.439-449. (Pubitemid 46845644)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 439-449
    • Esram, T.1    Chapman, P.L.2
  • 6
    • 0012485795 scopus 로고    scopus 로고
    • New MPPT Control Scheme Utilizing Power Balance at DC Link Instead of Array Power Detection
    • M. Matsui et al. : "New MPPT Control Scheme Utilizing Power Balance at DC Link Instead of Array Power Detection" , Proc. of IPEC-Tokyo, 2000, Vol.1, pp.164-169.
    • Proc. of IPEC-Tokyo, 2000 , vol.1 , pp. 164-169
    • Matsui, M.1
  • 7
    • 0035366448 scopus 로고    scopus 로고
    • Novel maximum-power-point-tracking controller for photovoltaic energy conversion system
    • DOI 10.1109/41.925586, PII S0278004601038126
    • Y. Kuo, et al. ́Novel Maximum-Power-Point-Tracking Controller for Photovoltaic Energy Conversion Systeḿ, IEEE Trans. Ind. Electron, 2001, Vol.48(3), pp.594-601. (Pubitemid 32609954)
    • (2001) IEEE Transactions on Industrial Electronics , vol.48 , Issue.3 , pp. 594-601
    • Kuo, Y.-C.1    Liang, T.-J.2    Chen, J.-F.3
  • 8
    • 0036475053 scopus 로고    scopus 로고
    • Short-Current Pulse-Based Maximum-Power-Point Tracking Method for Multiple Photovoltaic-and- Converter Module System
    • T. Noguchi, S. Togashi, R. Nakamolo, "Short-Current Pulse-Based Maximum-Power-Point Tracking Method for Multiple Photovoltaic-and- Converter Module System", IEEE Trans. on lndustrial Electronics, 2002, Vol.49, pp. 217-223.
    • (2002) IEEE Trans. on Lndustrial Electronics , vol.49 , pp. 217-223
    • Noguchi, T.1    Togashi, S.2    Nakamolo, R.3
  • 9
    • 1542329095 scopus 로고    scopus 로고
    • A study on a two stage maximum power point tracking control of a photovoltaic system under partially shaded insolation conditions
    • K. Kobayashi, I. Takano and Y. Sawada "A study on a two stage maximum power point tracking control of a photovoltaic system under partially shaded insolation conditions" Proc. of the IEEE Power Engineering Society General Meeting, 2003, Vol.4.
    • Proc. of the IEEE Power Engineering Society General Meeting, 2003 , vol.4
    • Kobayashi, K.1    Takano, I.2    Sawada, Y.3
  • 10
    • 0041524061 scopus 로고    scopus 로고
    • Neural-network-based maximum-power-point tracking of coupled-inductor interleaved-boostconverter-supplied PV system using fuzzy controller
    • Veerachary. M, Senjyu. T, Uezato. K, "Neural-network-based maximum-power-point tracking of coupled-inductor interleaved-boostconverter- supplied PV system using fuzzy controller", IEEE Trans. on Ind. Electron, 2003, Vol.50(4), pp. 749-758.
    • (2003) IEEE Trans. on Ind. Electron , vol.50 , Issue.4 , pp. 749-758
    • Veerachary, M.1    Senjyu, T.2    Uezato, K.3
  • 11
    • 22944480226 scopus 로고    scopus 로고
    • Optimization of perturb and observe maximum power point tracking method
    • DOI 10.1109/TPEL.2005.850975
    • N.Femia, G.Petrone, G.Spagnuolo, M.Vitelli: ́Optimization of Perturb and Observe Maximum Power Point Tracking Method́, IEEE Transactions on Power Electronics, Vol.20, N.4, July 2005, pp.963-973. (Pubitemid 41046704)
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.4 , pp. 963-973
    • Femia, N.1    Petrone, G.2    Spagnuolo, G.3    Vitelli, M.4
  • 13
    • 51249117917 scopus 로고    scopus 로고
    • Multidimensional Maximum Power Point Tracking Control for Converters Connected to Photovoltaic Arrays with Particle Swarm Optimization Technique
    • M. Miyatake, M. Veerachary, N. Fujii, F. Toriumi and N. A. Ahmed,"Multidimensional Maximum Power Point Tracking Control for Converters Connected to Photovoltaic Arrays with Particle Swarm Optimization Technique", Proc. of ICEMS, 2006.
    • Proc. of ICEMS, 2006
    • Miyatake, M.1    Veerachary, M.2    Fujii, N.3    Toriumi, F.4    Ahmed, N.A.5
  • 14
    • 33745727042 scopus 로고    scopus 로고
    • PSIM circuit-oriented simulator model for the nonlinear photovoltaic sources
    • Veerachary. M, "PSIM circuit-oriented simulator model for the nonlinear photovoltaic sources", IEEE Trans. on Aerospace \& Electronic Systems, 2006, Vol.42(2), pp. 735-740.
    • (2006) IEEE Trans. on Aerospace \& Electronic Systems , vol.42 , Issue.2 , pp. 735-740
    • Veerachary, M.1
  • 15
    • 27844552907 scopus 로고    scopus 로고
    • Power Tracking for Non-linear PV sources with Coupled Inductor SEPIC Converter
    • Mummadi Veerachary, "Power Tracking for Non-linear PV sources with Coupled Inductor SEPIC Converter," IEEE Trans. on Aerospace & Electronic Systems, 2005, Vol.41(3), pp. 1019-1029.
    • (2005) IEEE Trans. on Aerospace & Electronic Systems , vol.41 , Issue.3 , pp. 1019-1029
    • Veerachary, M.1
  • 16
    • 62949182946 scopus 로고    scopus 로고
    • Analysis of Photovoltaic Maximum Power Point Trackers
    • M.Veerachary, "Analysis of Photovoltaic Maximum Power Point Trackers," IEEJ Trans. on Industry applications, 2007, pp. 1215-1223.
    • (2007) IEEJ Trans. on Industry Applications , pp. 1215-1223
    • Veerachary, M.1
  • 18
    • 77952558781 scopus 로고    scopus 로고
    • PSIM, user manual, 2004
    • PSIM, user manual, 2004.
  • 19
    • 77952576163 scopus 로고    scopus 로고
    • dsPIC30F6010 user manual, Microchip Technologies, 2006
    • dsPIC30F6010 user manual, Microchip Technologies, 2006.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.