메뉴 건너뛰기




Volumn 17, Issue 1, 2010, Pages 108-114

Adjunctive iliac stents reduce the risk of stent-graft limb occlusion following endovascular aneurysm repair with the Zenith stent-graft

Author keywords

Abdominal aortic aneurysm; Adjunctive procedures; Endovascular aneurysm repair; Limb occlusion; Stent

Indexed keywords

AGED; ARTICLE; COMPARATIVE STUDY; DATA BASE; ENDOVASCULAR SURGERY; FOLLOW UP; GRAFT OCCLUSION; HUMAN; INCIDENCE; KAPLAN MEIER METHOD; LIMB; MALE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RISK; STENT; THROMBECTOMY; ABDOMINAL AORTA ANEURYSM; AORTOGRAPHY; BLOOD VESSEL PROSTHESIS; BLOOD VESSEL TRANSPLANTATION; CHI SQUARE DISTRIBUTION; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; ILIAC ARTERY; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; PROSTHESIS; RADIOGRAPHY; RISK ASSESSMENT; RISK FACTOR; TIME; TREATMENT OUTCOME;

EID: 77952539991     PISSN: 15266028     EISSN: 15451550     Source Type: Journal    
DOI: 10.1583/09-2854.1     Document Type: Article
Times cited : (49)

References (11)
  • 2
    • 0036636418 scopus 로고    scopus 로고
    • Limb interventions in patients undergoing treatment with an unsupported bifurcated aortic endograft system: A review of the Phase II EVT Trial
    • Fairman RM, Baum RA, Carpenter JP, et al. Limb interventions in patients undergoing treatment with an unsupported bifurcated aortic endograft system: a review of the Phase II EVT Trial. J Vasc Surg. 2002;36:118-126.
    • (2002) J Vasc Surg , vol.36 , pp. 118-126
    • Fairman, R.M.1    Baum, R.A.2    Carpenter, J.P.3
  • 3
    • 10944252856 scopus 로고    scopus 로고
    • Endovascular graft limb occlusion
    • Woody JD, Makaroun MS. Endovascular graft limb occlusion. Semin Vasc Surg. 2004;17:262-267.
    • (2004) Semin Vasc Surg , vol.17 , pp. 262-267
    • Woody, J.D.1    Makaroun, M.S.2
  • 4
    • 0035099062 scopus 로고    scopus 로고
    • Failure of endovascular abdominal aortic aneurysm graft limbs
    • Carpenter JP, Neschis DG, Fairman RM, et al. Failure of endovascular abdominal aortic aneurysm graft limbs. J Vasc Surg. 2001;33:296-303.
    • (2001) J Vasc Surg , vol.33 , pp. 296-303
    • Carpenter, J.P.1    Neschis, D.G.2    Fairman, R.M.3
  • 6
    • 33645739221 scopus 로고    scopus 로고
    • Adjunctive primary stenting of Zenith endograft limbs during endovascular abdominal aortic aneurysm repair: Implications for limb patency
    • Sivamurthy N, Schneider DB, Reilly LM, et al. Adjunctive primary stenting of Zenith endograft limbs during endovascular abdominal aortic aneurysm repair: implications for limb patency. J Vasc Surg. 2006;43:662-670.
    • (2006) J Vasc Surg , vol.43 , pp. 662-670
    • Sivamurthy, N.1    Schneider, D.B.2    Reilly, L.M.3
  • 7
    • 34249817552 scopus 로고    scopus 로고
    • Limb graft occlusion following EVAR: Clinical pattern, outcomes and predictive factors of occurrence
    • Cochennec F, Becquemin JP, Desgranges P, et al. Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. Eur J Vasc Endovasc Surg. 2007;34:59-65.
    • (2007) Eur J Vasc Endovasc Surg , vol.34 , pp. 59-65
    • Cochennec, F.1    Becquemin, J.P.2    Desgranges, P.3
  • 8
    • 0035489379 scopus 로고    scopus 로고
    • Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: Evaluation of 3D computer-based assessment
    • Wolf YG, Tillich M, Lee WA, et al. Impact of aortoiliac tortuosity on endovascular repair of abdominal aortic aneurysms: evaluation of 3D computer-based assessment. J Vasc Surg. 2001;34:594-599.
    • (2001) J Vasc Surg , vol.34 , pp. 594-599
    • Wolf, Y.G.1    Tillich, M.2    Lee, W.A.3
  • 9
    • 0034126191 scopus 로고    scopus 로고
    • Mechanical properties of metallic stents: How do these properties influence the choice of stent for specific lesions?
    • Dyet JF, Watts WG, Ettles DF, et al. Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions? Cardiovasc Intervent Radiol. 2000;23:47-54.
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 47-54
    • Dyet, J.F.1    Watts, W.G.2    Ettles, D.F.3
  • 10
    • 0036695745 scopus 로고    scopus 로고
    • A comparison of balloon and self-expanding stents
    • Duerg TW, Wholey M. A comparison of balloon and self-expanding stents. Min Invas Ther & Allied Technol. 2002;11:173-178.
    • (2002) Min Invas Ther & Allied Technol , vol.11 , pp. 173-178
    • Duerg, T.W.1    Wholey, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.