메뉴 건너뛰기




Volumn 6, Issue 3, 2010, Pages 351-360

The future of new aortic valve replacement approaches

Author keywords

Aortic valve disease; Aortic valve stenosis; Transcatheter aortic valve implantation

Indexed keywords

AORTA VALVE DISEASE; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; AORTIC VALVE REPAIR; COMORBIDITY; DEVELOPED COUNTRY; DISEASE SEVERITY; FEASIBILITY STUDY; FOLLOW UP; HIGH RISK PATIENT; HUMAN; MORBIDITY; MORTALITY; NONHUMAN; PATIENT SELECTION; PRIORITY JOURNAL; PROGNOSIS; REVIEW; RISK BENEFIT ANALYSIS; SURGICAL APPROACH; SURGICAL TECHNIQUE; TREATMENT CONTRAINDICATION;

EID: 77952529844     PISSN: 14796678     EISSN: 17448298     Source Type: Journal    
DOI: 10.2217/fca.10.14     Document Type: Review
Times cited : (5)

References (66)
  • 1
    • 0038267070 scopus 로고    scopus 로고
    • A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease
    • A complete and clear overview of valve disease in Europe
    • Iung B, Baron G, Butchart EG et al.: A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease. Eur. Heart. J. 24 (13), 1231-1243 (2003). A complete and clear overview of valve disease in Europe.
    • (2003) Eur. Heart. J. , vol.24 , Issue.13 , pp. 1231-1243
    • Iung, B.1    Baron, G.2    Butchart, E.G.3
  • 2
    • 33746862304 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation in humans
    • Lichtenstein V, Cheung A, Ye J et al.: Transapical transcatheter aortic valve implantation in humans. Circulation 114 (6), 591-596 (2006).
    • (2006) Circulation , vol.114 , Issue.6 , pp. 591-596
    • Lichtenstein, V.1    Cheung, A.2    Ye, J.3
  • 3
    • 0019958867 scopus 로고
    • The effect of aortic valve replacement on survival
    • Schwarz F, Baumann P, Manthey et al.: The effect of aortic valve replacement on survival. Circulation 66 (5), 1105-1110 (1982).
    • (1982) Circulation , vol.66 , Issue.5 , pp. 1105-1110
    • Schwarz, F.1    Baumann, P.2    Manthey3
  • 4
    • 33747116680 scopus 로고    scopus 로고
    • ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American college of cardiology/american heart association task force on practice guidelines
    • (writing committee to revise the 1998 guidelines for the management of patients with valvular heart disease): Developed in collaboration with the society of cardiovascular anesthesiologists: Endorsed by the society for cardiovascular angiography and interventions and the society of thoracic surgeons
    • Bonow RO, Carabello BA, Chatterjee K et al.: ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation 114 (5), E84-E231 (2006).
    • (2006) Circulation , vol.114 , Issue.5
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3
  • 5
    • 0028154041 scopus 로고
    • Three-year outcome after balloon aortic valvuloplasty: Insights into prognosis of valvular aortic stenosis
    • Otto CM, Mickel MC, Kennedy JW et al.: Three-year outcome after balloon aortic valvuloplasty: insights into prognosis of valvular aortic stenosis. Circulation 89 (2), 642-650 (1994).
    • (1994) Circulation , vol.89 , Issue.2 , pp. 642-650
    • Otto, C.M.1    Mickel, M.C.2    Kennedy, J.W.3
  • 6
    • 61849113386 scopus 로고    scopus 로고
    • Aortic stenosis
    • Carabello B: Aortic stenosis. Lancet 373 (9667), 956-966 (2009).
    • (2009) Lancet , vol.373 , Issue.9667 , pp. 956-966
    • Carabello, B.1
  • 7
    • 0014313368 scopus 로고
    • Aortic stenosis
    • Ross J Jr, Braunwald E: Aortic stenosis. Circulation 38 (1 Suppl.), 61-67 (1968).
    • (1968) Circulation , vol.38 , Issue.1 SUPPL. , pp. 61-67
    • Ross Jr., J.1    Braunwald, E.2
  • 8
    • 64749089010 scopus 로고    scopus 로고
    • Characterization and outcome of patients with severe symptomatic aortic stenosis referred for percutaneous aortic valve replacement
    • Kapadia SR, Goel SS, Svensson L et al.: Characterization and outcome of patients with severe symptomatic aortic stenosis referred for percutaneous aortic valve replacement. J. Thorac. Cardiovasc. Surg. 137 (6), 1430-1437 (2009).
    • (2009) J. Thorac. Cardiovasc. Surg. , vol.137 , Issue.6 , pp. 1430-1437
    • Kapadia, S.R.1    Goel, S.S.2    Svensson, L.3
  • 9
    • 0031461046 scopus 로고    scopus 로고
    • Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair
    • Cohn LH, Adams DH, Couper GS et al.: Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of cardiac valve replacement and repair. Ann. Surg. 226 (4), 421-426 (1997).
    • (1997) Ann. Surg. , vol.226 , Issue.4 , pp. 421-426
    • Cohn, L.H.1    Adams, D.H.2    Couper, G.S.3
  • 10
    • 32144439987 scopus 로고    scopus 로고
    • Direct access valve replacement (DAVR) - Are we entering a new era in cardiac surgery?
    • Huber CH, von Segesser LK: Direct access valve replacement (DAVR) - are we entering a new era in cardiac surgery? Eur. J. Cardiothorac. Surg. 29 (3), 380-385 (2006).
    • (2006) Eur. J. Cardiothorac. Surg. , vol.29 , Issue.3 , pp. 380-385
    • Huber, C.H.1    Von Segesser, L.K.2
  • 11
    • 0028871613 scopus 로고
    • Balloon aortic valvuloplasty in adults: Failure of procedure to improve long-term survival
    • Lieberman EB, Bashore TM, Hermiller JB et al.: Balloon aortic valvuloplasty in adults: failure of procedure to improve long-term survival. J. Am. Coll. Cardiol. 26 (6), 1522-1528 (1995).
    • (1995) J. Am. Coll. Cardiol. , vol.26 , Issue.6 , pp. 1522-1528
    • Lieberman, E.B.1    Bashore, T.M.2    Hermiller, J.B.3
  • 12
    • 0026562077 scopus 로고
    • Transluminal implantation of artifcial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs
    • Andersen HR, Knudsen LL, Hasenkam JM et al.: Transluminal implantation of artifcial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. Eur. Heart J. 13 (3), 704-708 (1992).
    • (1992) Eur. Heart J. , vol.13 , Issue.3 , pp. 704-708
    • Andersen, H.R.1    Knudsen, L.L.2    Hasenkam, J.M.3
  • 13
    • 0034699902 scopus 로고    scopus 로고
    • Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    • Bonhoeffer P, Boudjemline Y, Saliba Z et al.: Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet 356 (9239), 1403-1405 (2000).
    • (2000) Lancet , vol.356 , Issue.9239 , pp. 1403-1405
    • Bonhoeffer, P.1    Boudjemline, Y.2    Saliba, Z.3
  • 14
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • This work began a new era in valve disease therapies
    • Cribier A, Eltchaninoff H, Bash A et al.: Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106 (24), 3006-3008 (2002). This work began a new era in valve disease therapies.
    • (2002) Circulation , vol.106 , Issue.24 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 15
    • 0025728874 scopus 로고
    • Aortic valve replacement for aortic stenosis in persons aged 80 years and over
    • Culliford AT, Galloway AC, Colvin SB et al.: Aortic valve replacement for aortic stenosis in persons aged 80 years and over. Am. J. Cardiol. 67 (15), 1256-1260 (1991).
    • (1991) Am. J. Cardiol. , vol.67 , Issue.15 , pp. 1256-1260
    • Culliford, A.T.1    Galloway, A.C.2    Colvin, S.B.3
  • 16
    • 0037061912 scopus 로고    scopus 로고
    • Hospital volume and surgical mortality in the United States
    • Birkmeyer JD, Siewers AE, Finlayson EV et al.: Hospital volume and surgical mortality in the United States. N. Engl. J. Med. 346 (15), 1128-1137 (2002).
    • (2002) N. Engl. J. Med. , vol.346 , Issue.15 , pp. 1128-1137
    • Birkmeyer, J.D.1    Siewers, A.E.2    Finlayson, E.V.3
  • 17
    • 0034077473 scopus 로고    scopus 로고
    • Long-term follow-up of morbidity and mortality after aortic valve replacement with a mechanical valve prosthesis
    • Kvidal P, Bergstrodie;m R, Malm T et al.: Long-term follow-up of morbidity and mortality after aortic valve replacement with a mechanical valve prosthesis. Eur. Heart J. 21 (13), 1099-1111 (2000).
    • (2000) Eur. Heart J. , vol.21 , Issue.13 , pp. 1099-1111
    • Kvidal, P.1    Bergstrodie2    m, R.3    Malm, T.4
  • 19
    • 0030992408 scopus 로고    scopus 로고
    • The society of thoracic surgeons national cardiac surgery database: Current risk assessment
    • Edwards FH, Grover FL, Shroyer AL, Schwartz M, Bero J: The Society of Thoracic Surgeons National Cardiac Surgery Database: current risk assessment. Ann. Thorac. Surg. 63 (3), 903-908 (1997).
    • (1997) Ann. Thorac. Surg. , vol.63 , Issue.3 , pp. 903-908
    • Edwards, F.H.1    Grover, F.L.2    Shroyer, A.L.3    Schwartz, M.4    Bero, J.5
  • 20
    • 37249022337 scopus 로고    scopus 로고
    • High-risk aortic valve replacement: Are the outcomes as bad as predicted?
    • Grossi EA, Schwartz CF, Yu PJ et al.: High-risk aortic valve replacement: are the outcomes as bad as predicted? Ann. Thorac. Surg. 8 (1), 102-106 (2008).
    • (2008) Ann. Thorac. Surg. , vol.8 , Issue.1 , pp. 102-106
    • Grossi, E.A.1    Schwartz, C.F.2    Yu, P.J.3
  • 21
    • 33646828787 scopus 로고    scopus 로고
    • Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15 years after aortic valve replacement
    • Chan V, Jamieson WR, Germann E et al.: Performance of bioprostheses and mechanical prostheses assessed by composites of valve-related complications to 15 years after aortic valve replacement. J. Thorac. Cardiovasc. Surg. 131 (6), 1267-1273 (2006).
    • (2006) J. Thorac. Cardiovasc. Surg. , vol.131 , Issue.6 , pp. 1267-1273
    • Chan, V.1    Jamieson, W.R.2    Germann, E.3
  • 22
    • 38049129137 scopus 로고    scopus 로고
    • Choice of prosthetic heart valve in today's practice
    • El Oakley R, Kleine P, Bach DS: Choice of prosthetic heart valve in today's practice. Circulation 117 (2), 253-256 (2008).
    • (2008) Circulation , vol.117 , Issue.2 , pp. 253-256
    • Oakley, R.E.1    Kleine, P.2    Bach, D.S.3
  • 24
    • 77952519352 scopus 로고    scopus 로고
    • Access and closure issues the subclavian/trans-axillary approach
    • Presented at:, Seattle, WA, USA, 25-26 June
    • Laborde JC: Access and closure issues the subclavian/trans-axillary approach. Presented at: Trancatheter Valve Therapies. Seattle, WA, USA, 25-26 June, 2009.
    • (2009) Trancatheter Valve Therapies.
    • Laborde, J.C.1
  • 25
    • 40449124366 scopus 로고    scopus 로고
    • Aortic bioprosthesis implanted percutaneously: Three year follow up
    • Eltchaninoff H, Tron C, Bauer F et al.: Aortic bioprosthesis implanted percutaneously: three year follow up. Arch. Mal. Coeur. Vaiss. 100 (11), 901-908 (2007).
    • (2007) Arch. Mal. Coeur. Vaiss. , vol.100 , Issue.11 , pp. 901-908
    • Eltchaninoff, H.1    Tron, C.2    Bauer, F.3
  • 26
    • 65149084265 scopus 로고    scopus 로고
    • The SOURCE registry
    • Presented at:, Washington, DC, USA, 13 October
    • Lefevre T: The SOURCE Registry Presented at: Transcatheter Cardiovascular Therapeutics. Washington, DC, USA, 13 October, 2008.
    • (2008) Transcatheter Cardiovascular Therapeutics
    • Lefevre, T.1
  • 27
    • 33644860328 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation retrograde from the femoral artery
    • Webb JG, Chandavimol M, Thompson CR et al.: Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 113 (6), 842-850 (2006).
    • (2006) Circulation , vol.113 , Issue.6 , pp. 842-850
    • Webb, J.G.1    Chandavimol, M.2    Thompson, C.R.3
  • 28
    • 67649756770 scopus 로고    scopus 로고
    • Unexpected complications of transapical aortic valve implantation
    • Al-Attar: Unexpected complications of transapical aortic valve implantation. Ann. Thorac. Surg. 88 (1), 90-94 (2009).
    • (2009) Ann. Thorac. Surg. , vol.88 , Issue.1 , pp. 90-94
    • Al-Attar1
  • 29
    • 33746862304 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation in humans: Initial clinical experience
    • Lichtenstein SV, Cheung A, Ye J et al.: Transapical transcatheter aortic valve implantation in humans: initial clinical experience. Circulation 114 (6), 591-596 (2006).
    • (2006) Circulation , vol.114 , Issue.6 , pp. 591-596
    • Lichtenstein, S.V.1    Cheung, A.2    Ye, J.3
  • 30
    • 47049087117 scopus 로고    scopus 로고
    • United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex
    • Svensson LG, Dewey T, Kapadia S et al.: United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. Ann. Thorac. Surg. 86 (1), 46-55 (2008).
    • (2008) Ann. Thorac. Surg. , vol.86 , Issue.1 , pp. 46-55
    • Svensson, L.G.1    Dewey, T.2    Kapadia, S.3
  • 32
    • 65149101505 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Traverce Feasibility Study
    • Presented at:, Washington, DC, USA 13 October
    • Walther T: Transapical aortic valve implantation: Traverce Feasibility Study. Presented at: Transcatheter Cardiovascular Therapeutics. Washington, DC, USA 13 October, 2008.
    • (2008) Transcatheter Cardiovascular Therapeutics.
    • Walther, T.1
  • 34
    • 62149089188 scopus 로고    scopus 로고
    • Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team
    • Bleiziffer Ruge H, Mazzitelli D et al.: Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team. Eur. J. Cardiothorac. Surg. 35 (4), 615-621 (2009).
    • (2009) Eur. J. Cardiothorac. Surg. , vol.35 , Issue.4 , pp. 615-621
    • Ruge, H.B.1    Mazzitelli, D.2
  • 35
    • 77952480328 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation; the initial 50 patients
    • Walther T, Falk V, Kempfert J et al.: Transapical minimally invasive aortic valve implantation; the initial 50 patients. Eur. J. Cardiothorac. Surg. 35 (2), 376-377 (2008).
    • (2008) Eur. J. Cardiothorac. Surg. , vol.35 , Issue.2 , pp. 376-377
    • Walther, T.1    Falk, V.2    Kempfert, J.3
  • 36
    • 58249134729 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation: 1-year outcome in 26 patients
    • Ye J, Cheung A, Lichtenstein SV et al.: Transapical transcatheter aortic valve implantation: 1-year outcome in 26 patients. J. Thorac. Cardiovasc. Surg. 137 (1), 167-173 (2009).
    • (2009) J. Thorac. Cardiovasc. Surg. , vol.137 , Issue.1 , pp. 167-173
    • Ye, J.1    Cheung, A.2    Lichtenstein, S.V.3
  • 37
    • 33749634251 scopus 로고    scopus 로고
    • Percutaneous implantation of the CoreValve self expanding valve prosthesis in high risk patients with aortic valve disease
    • Grube E, Laborde JC, Gerckens U et al.: Percutaneous implantation of the CoreValve self expanding valve prosthesis in high risk patients with aortic valve disease. Circulation 114 (15), 1616-1624 (2006).
    • (2006) Circulation , vol.114 , Issue.15 , pp. 1616-1624
    • Grube, E.1    Laborde, J.C.2    Gerckens, U.3
  • 39
    • 55849132881 scopus 로고    scopus 로고
    • ™ System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • ™ System: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. Eurointervention 4 (2), 242-249 (2008).
    • (2008) Eurointervention , vol.4 , Issue.2 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3
  • 40
    • 65149088122 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation with the CoreValve ReValving Device
    • Presented at:, Washington, DC, USA, 12 October
    • Laborde JC: Transcatheter aortic valve implantation with the CoreValve ReValving Device. Presented at: Transcatheter Cardiovascular Therapeutics. Washington, DC, USA, 12 October 2008.
    • (2008) Transcatheter Cardiovascular Therapeutics
    • Laborde, J.C.1
  • 42
    • 65549143852 scopus 로고    scopus 로고
    • The valve-in-valve technique: Transcatheter treatment of aortic bioprothesis malposition
    • Ussia GP, Mulè M, Tamburino C: The valve-in-valve technique: transcatheter treatment of aortic bioprothesis malposition. Catheter Cardiovasc. Inter. 73 (5), 713-716 (2009).
    • (2009) Catheter Cardiovasc. Inter. , vol.73 , Issue.5 , pp. 713-716
    • Ussia, G.P.1    Mulè, M.2    Tamburino, C.3
  • 43
    • 24944474929 scopus 로고    scopus 로고
    • First human case of retrograde transcatheter implantation of an aortic valve prosthesis
    • Paniagua D, Condado JA, Besso J et al.: First human case of retrograde transcatheter implantation of an aortic valve prosthesis. Tex. Heart Inst. J. 32 (3), 393-398 (2005).
    • (2005) Tex. Heart Inst. J. , vol.32 , Issue.3 , pp. 393-398
    • Paniagua, D.1    Condado, J.A.2    Besso, J.3
  • 44
    • 58749090760 scopus 로고    scopus 로고
    • Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis. A first-in-man feasibility and safety study
    • Schofer J, Treede H et al.: Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis. A first-in-man feasibility and safety study. Circ. Cardiovasc. Intervent. 4 (1), 126-133 (2008).
    • (2008) Circ. Cardiovasc. Intervent. , vol.4 , Issue.1 , pp. 126-133
    • Schofer, J.1    Treede, H.2
  • 45
    • 55849103064 scopus 로고    scopus 로고
    • Direct flow medical percutaneous aortic valve: Proof of concept
    • Low RI, Bolling SF, Yeo KK, Ebner A: Direct flow medical percutaneous aortic valve: proof of concept. EuroIntervention 4 (2), 256-261 (2008).
    • (2008) EuroIntervention , vol.4 , Issue.2 , pp. 256-261
    • Low, R.I.1    Bolling, S.F.2    Yeo, K.K.3    Ebner, A.4
  • 46
    • 42249087162 scopus 로고    scopus 로고
    • Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis
    • Demonstrated redeliverability of percutaneous prostheses
    • Buellesfeld L, Gerckens U, Grube E: Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis. Catheter. Cardiovasc. Interv. 71, 579-584 (2008). Demonstrated redeliverability of percutaneous prostheses.
    • (2008) Catheter. Cardiovasc. Interv. , vol.71 , pp. 579-584
    • Buellesfeld, L.1    Gerckens, U.2    Grube, E.3
  • 47
    • 55049112707 scopus 로고    scopus 로고
    • Staged approach towards interventional aortic valve implantation with a sutureless valve: Initial human implants
    • Shrestha M, Khaladj N, Bara C, Hoeffler K, Hagl C, Haverich A: Staged Approach towards Interventional Aortic Valve Implantation with a Sutureless Valve: initial human implants. Thorac. Cardiovasc. Surg. 56 (7), 398-400 (2008).
    • (2008) Thorac. Cardiovasc. Surg. , vol.56 , Issue.7 , pp. 398-400
    • Shrestha, M.1    Khaladj, N.2    Bara, C.3    Hoeffler, K.4    Hagl, C.5    Haverich, A.6
  • 48
    • 70350520484 scopus 로고    scopus 로고
    • Experimental evaluation of the JenaClip transcatheter aortic valve
    • DOI: Epub ahead of print, Completely new percutaneous prosthesis
    • Lauten A, Ferrari M, Petri A et al.: Experimental evaluation of the JenaClip transcatheter aortic valve. Catheter. Cardiovasc. Interv. DOI: 2009 (Epub ahead of print). Completely new percutaneous prosthesis.
    • (2009) Catheter. Cardiovasc. Interv.
    • Lauten, A.1    Ferrari, M.2    Petri, A.3
  • 49
    • 33748937701 scopus 로고    scopus 로고
    • A repositionable valved stent for endovascular treatment of deteriorated bioprostheses
    • Zegdi R, Khabbaz Z, Borenstein N, Fabiani JN: A repositionable valved stent for endovascular treatment of deteriorated bioprostheses. J. Am. Coll. Cardiol. 48 (7), 1365-1368 (2006).
    • (2006) J. Am. Coll. Cardiol. , vol.48 , Issue.7 , pp. 1365-1368
    • Zegdi, R.1    Khabbaz, Z.2    Borenstein, N.3    Fabiani, J.N.4
  • 50
    • 0034619381 scopus 로고    scopus 로고
    • Tissue engineering of pulmonary heart valves on allogenic acellular matrix conduits: In vivo restoration of valve tissue
    • III
    • Steinhoff G, Stock U, Karim N et al.: Tissue engineering of pulmonary heart valves on allogenic acellular matrix conduits: in vivo restoration of valve tissue. Circulation 102 (19 Suppl 3), III 50-55 (2000).
    • (2000) Circulation , vol.102 , Issue.19 SUPPL 3 , pp. 50-55
    • Steinhoff, G.1    Stock, U.2    Karim, N.3
  • 52
    • 60749094809 scopus 로고    scopus 로고
    • New anatomically oriented transapical aortic valve implantation
    • Falk V, Schwammenthal EE, Kempfert J et al.: New Anatomically Oriented Transapical Aortic Valve Implantation. Ann. Thor. Surg. 87, 925-926 (2009).
    • (2009) Ann. Thor. Surg. , vol.87 , pp. 925-926
    • Falk, V.1    Schwammenthal, E.E.2    Kempfert, J.3
  • 53
    • 44949107279 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • The first European consenus document regarding percutaneous valvular prostheses
    • Vahanian A, Alfieri O, Al-Attar N et al.: Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur. Heart. J. 29 (11), 1463-1470 (2008). The first European consenus document regarding percutaneous valvular prostheses.
    • (2008) Eur. Heart. J. , vol.29 , Issue.11 , pp. 1463-1470
    • Vahanian, A.1    Alfieri, O.2    Al-Attar, N.3
  • 54
    • 65649146904 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Selection strategy is crucial for outcome
    • Al-Attar N, Himbert D, Descoutures F et al.: Transcatheter aortic valve implantation: selection strategy is crucial for outcome. Ann. Thorac. Surg 87 (6), 1757-1762 (2009).
    • (2009) Ann. Thorac. Surg. , vol.87 , Issue.6 , pp. 1757-1762
    • Al-Attar, N.1    Himbert, D.2    Descoutures, F.3
  • 55
    • 0034792414 scopus 로고    scopus 로고
    • Risk factors for early mortality after valve surgery in Europe in the 1990s: lessons from the EuroSCORE pilot program
    • EuroSCORE study group
    • Roques F, Nashef SA, Michel P: EuroSCORE study group. Risk factors for early mortality after valve surgery in Europe in the 1990s: lessons from the EuroSCORE pilot program. J. Heart. Valve. Dis. 10 (5), 572-577 (2001).
    • (2001) J. Heart. Valve. Dis. , vol.10 , Issue.5 , pp. 572-577
    • Roques, F.1    Nashef, S.A.2    Michel, P.3
  • 57
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • Tops LF, Wood DA, Delgado V et al.: Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1 (3), 321-330 (2008).
    • (2008) JACC Cardiovasc. Imaging , vol.1 , Issue.3 , pp. 321-330
    • Tops, L.F.1    Wood, D.A.2    Delgado, V.3
  • 58
    • 41249087660 scopus 로고    scopus 로고
    • Role of echocardiography in percutaneous aortic valve implantation
    • Moss RR, Ivens E, Pasupati S et al.: Role of echocardiography in percutaneous aortic valve implantation. JACC Cardiovasc Imaging 1 (1), 15-24 (2008).
    • (2008) JACC Cardiovasc. Imaging , vol.1 , Issue.1 , pp. 15-24
    • Moss, R.R.1    Ivens, E.2    Pasupati, S.3
  • 59
    • 33747362048 scopus 로고    scopus 로고
    • Prosthetic heart valves: Objective performance criteria versus randomized clinical trial
    • Grunkemeier GL, Jin R, Starr A.: Prosthetic heart valves: objective performance criteria versus randomized clinical trial. Ann. Thorac. Surg. 82 (3), 776-780 (2006).
    • (2006) Ann. Thorac. Surg. , vol.82 , Issue.3 , pp. 776-780
    • Grunkemeier, G.L.1    Jin, R.2    Starr, A.3
  • 60
    • 0034700972 scopus 로고    scopus 로고
    • Assessment of aortic valve stenosis severity: A new index based on the energy loss concept
    • Garcia D, Pibarot P, Dumesnil JG, Sakr F, Durand LG: Assessment of aortic valve stenosis severity: A new index based on the energy loss concept. Circulation 101 (7), 765-771 (2000).
    • (2000) Circulation , vol.101 , Issue.7 , pp. 765-771
    • Garcia, D.1    Pibarot, P.2    Dumesnil, J.G.3    Sakr, F.4    Durand, L.G.5
  • 61
    • 49549121647 scopus 로고    scopus 로고
    • Percutaneous transcatheter aortic valve implantation: Assessing results, judging outcomes, and planning trials: The interventionalist perspective
    • Chiam P T, Ruiz CE: Percutaneous transcatheter aortic valve implantation: assessing results, judging outcomes, and planning trials: the interventionalist perspective. JACC Cardiovasc. Interv. 1 (4), 341-350 (2008).
    • (2008) JACC Cardiovasc. Interv. , vol.1 , Issue.4 , pp. 341-350
    • Chiam, P.T.1    Ruiz, C.E.2
  • 62
    • 67651092115 scopus 로고    scopus 로고
    • Transapical off-pump removal of the native aortic valve: A proof-of-concept animal study
    • Salizzoni S, Bajona P, Zehr KJ et al.: Transapical off-pump removal of the native aortic valve: a proof-of-concept animal study. J. Thorac. Cardiovasc. Surg. 138, 468-473 (2009).
    • (2009) J. Thorac. Cardiovasc. Surg. , vol.138 , pp. 468-473
    • Salizzoni, S.1    Bajona, P.2    Zehr, K.J.3
  • 63
    • 34848924964 scopus 로고    scopus 로고
    • Exploration of the value of healthrelated quality-of-life information from clinical research and into clinical practice
    • Guyatt GH, Ferrans CE, Halyard MY et al.: Exploration of the value of healthrelated quality-of-life information from clinical research and into clinical practice. Mayo Clin. Proc. 82 (10), 1229-1239 (2007).
    • (2007) Mayo Clin. Proc. , vol.82 , Issue.10 , pp. 1229-1239
    • Guyatt, G.H.1    Ferrans, C.E.2    Halyard, M.Y.3
  • 64
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • Webb JG, Altwegg L, Boone RH et al.: Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation 119 (23), 3009-3016 (2009).
    • (2009) Circulation , vol.119 , Issue.23 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 65
    • 34547919242 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve replacement in selcted high-risk patients with aortic stenosis
    • Webb JG, Pasupati S, Humphries K et al.: Percutaneous transarterial aortic valve replacement in selcted high-risk patients with aortic stenosis. Circulation 116 (7), 755-763 (2007).
    • (2007) Circulation , vol.116 , Issue.7 , pp. 755-763
    • Webb, J.G.1    Pasupati, S.2    Humphries, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.