메뉴 건너뛰기




Volumn 24, Issue 5, 2010, Pages 894-900

The Cataract National Dataset electronic multicentre audit of 55 567 operations: When should IOLMaster biometric measurements be rechecked?

Author keywords

Axial length; Biometry; Cataract surgery; Keratometry

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; CATARACT; CATARACT EXTRACTION; CONTROLLED STUDY; EYE SURGERY; FEMALE; HUMAN; LENS IMPLANT; MAJOR CLINICAL STUDY; MALE;

EID: 77952494774     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/eye.2009.196     Document Type: Article
Times cited : (43)

References (36)
  • 1
    • 0033951073 scopus 로고    scopus 로고
    • Surgical prevention of posterior capsule opacification. Part 1: Progress in eliminating this complication of cataract surgery
    • Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M et al. Surgical prevention of posterior capsule opacification. Part 1: progress in eliminating this complication of cataract surgery. J Cataract Refract Surg 2000;26(2):180-187.
    • (2000) J. Cataract Refract. Surg. , vol.26 , Issue.2 , pp. 180-187
    • Apple, D.J.1    Peng, Q.2    Visessook, N.3    Werner, L.4    Pandey, S.K.5    Escobar-Gomez, M.6
  • 3
    • 0027442385 scopus 로고
    • The Hoffer Q formula: A comparison of theoretic and regression formulas
    • Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 1993;19(6):700-712.
    • (1993) J. Cataract Refract. Surg. , vol.19 , Issue.6 , pp. 700-712
    • Hoffer, K.J.1
  • 4
    • 0025315983 scopus 로고
    • Development of the SRK/T intraocular lens implant power calculation formula
    • Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 1990;16(3):333-340.
    • (1990) J. Cataract Refract. Surg. , vol.16 , Issue.3 , pp. 333-340
    • Retzlaff, J.A.1    Sanders, D.R.2    Kraff, M.C.3
  • 5
    • 33845734984 scopus 로고    scopus 로고
    • Errata in printed Hoffer Q formula
    • Hoffer KJ. Errata in printed Hoffer Q formula. J Cataract Refract Surg 2007;33:2-3.
    • (2007) J. Cataract Refract. Surg. , vol.33 , pp. 2-3
    • Hoffer, K.J.1
  • 6
    • 0023858680 scopus 로고
    • Comparison of the SRK II formula and other second generation formulas
    • Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second generation formulas. J Cataract Refract Surg 1988;14(2):136-141.
    • (1988) J. Cataract Refract. Surg. , vol.14 , Issue.2 , pp. 136-141
    • Sanders, D.R.1    Retzlaff, J.2    Kraff, M.C.3
  • 8
    • 19944421726 scopus 로고    scopus 로고
    • Royal College of Ophthalmologists, updated, accessed 18 July 2009
    • Royal College of Ophthalmologists. Cataract surgery guidelines 2004, updated 2007. http://www.rcophth.ac.uk/docs/publications/published-guidelines /FinalVersionGuidelinesApril2007Updated.pdf (accessed 18 July 2009).
    • (2004) Cataract Surgery Guidelines
  • 9
    • 58249105826 scopus 로고    scopus 로고
    • The Cataract National Dataset electronic multi-centre audit of 55 567 operations: Updating benchmark standards of care in the United Kingdom and internationally
    • Jaycock P, Johnston RL, Taylor H, Adams M, Tole DM, Galloway P et al. The Cataract National Dataset electronic multi-centre audit of 55 567 operations: updating benchmark standards of care in the United Kingdom and internationally. Eye 2009;23(1):38-49.
    • (2009) Eye , vol.23 , Issue.1 , pp. 38-49
    • Jaycock, P.1    Johnston, R.L.2    Taylor, H.3    Adams, M.4    Tole, D.M.5    Galloway, P.6
  • 11
    • 0019432970 scopus 로고
    • The accuracy of ultrasonic measurement of the axial length of the eye
    • Binkhorst RD. The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surg 1981;12(5):363-365.
    • (1981) Ophthalmic Surg. , vol.12 , Issue.5 , pp. 363-365
    • Binkhorst, R.D.1
  • 12
    • 0019156126 scopus 로고
    • Accuracy of intraocular lens powers calculated from A-scan biometry with the echo-oculometer
    • Schachar RA, Levy NS, Bonney RC. Accuracy of intraocular lens powers calculated from A-scan biometry with the echo-oculometer. Ophthalmic Surg 1980;11(12):856-858.
    • (1980) Ophthalmic Surg. , vol.11 , Issue.12 , pp. 856-858
    • Schachar, R.A.1    Levy, N.S.2    Bonney, R.C.3
  • 13
    • 41949113224 scopus 로고    scopus 로고
    • Sources of error in intraocular lens power calculation
    • Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg 2008;34(3):368-376.
    • (2008) J. Cataract Refract. Surg. , vol.34 , Issue.3 , pp. 368-376
    • Norrby, S.1
  • 14
    • 0742305077 scopus 로고    scopus 로고
    • Ocular component measurement using the Zeiss IOLMaster
    • Sheng H, Bottjer CA, Bullimore MA. Ocular component measurement using the Zeiss IOLMaster. Optom Vis Sci 2004;81(1):27-34.
    • (2004) Optom. Vis. Sci. , vol.81 , Issue.1 , pp. 27-34
    • Sheng, H.1    Bottjer, C.A.2    Bullimore, M.A.3
  • 15
    • 0025676380 scopus 로고
    • Calculated versus A-scan result for axial length using different types of ultrasound probe tip
    • Pt
    • Snead MP, Rubinstein MP, Lea SH, Haworth SM. Calculated versus A-scan result for axial length using different types of ultrasound probe tip. Eye 1990;4 (Pt 5):718-722.
    • (1990) Eye , vol.4 , Issue.5 , pp. 718-722
    • Snead, M.P.1    Rubinstein, M.P.2    Lea, S.H.3    Haworth, S.M.4
  • 16
    • 0035140259 scopus 로고    scopus 로고
    • Power vector analysis of the optical outcome of refractive surgery
    • Thibos LN, Horner D. Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg 2001;27(1):80-85.
    • (2001) J. Cataract Refract. Surg. , vol.27 , Issue.1 , pp. 80-85
    • Thibos, L.N.1    Horner, D.2
  • 18
  • 20
    • 0038239506 scopus 로고    scopus 로고
    • Preoperative biometry of cataractous eyes using partial coherence laser interferometry
    • Hasemeyer S, Hugger P, Jonas JB. Preoperative biometry of cataractous eyes using partial coherence laser interferometry. Graefes Arch Clin Exp Ophthalmol 2003;241(3):251-252.
    • (2003) Graefes Arch. Clin. Exp. Ophthalmol. , vol.241 , Issue.3 , pp. 251-252
    • Hasemeyer, S.1    Hugger, P.2    Jonas, J.B.3
  • 21
    • 0036171164 scopus 로고    scopus 로고
    • Immersion A-scan compared with partial coherence interferometry: Outcomes analysis
    • Packer M, Fine IH, Hoffman RS. Immersion A-scan compared with partial coherence interferometry: outcomes analysis. J Cataract Refract Surg 2002;28(2):239-242.
    • (2002) J. Cataract Refract. Surg. , vol.28 , Issue.2 , pp. 239-242
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3
  • 22
    • 0033805274 scopus 로고    scopus 로고
    • Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
    • Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000;238: 765-773.
    • (2000) Graefes Arch. Clin. Exp. Ophthalmol. , vol.238 , pp. 765-773
    • Haigis, W.1    Lege, B.2    Miller, N.3    Schneider, B.4
  • 23
    • 0029028130 scopus 로고
    • Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm
    • Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg 1995;21(3):313-319.
    • (1995) J. Cataract Refract. Surg. , vol.21 , Issue.3 , pp. 313-319
    • Olsen, T.1    Corydon, L.2    Gimbel, H.3
  • 24
    • 5444256326 scopus 로고
    • A-scan biometry of 1000 cataractous eyes
    • Shammas HJ. A-scan biometry of 1000 cataractous eyes. Doc Ophthalmol Proc Ser 1987;48: 57-63.
    • (1987) Doc Ophthalmol. Proc. Ser , vol.48 , pp. 57-63
    • Shammas, H.J.1
  • 25
    • 0018937490 scopus 로고
    • Biometry of 7, 500 cataractous eyes
    • Hoffer KJ. Biometry of 7, 500 cataractous eyes. Am J Ophthalmol 1980;90(3):360-368.
    • (1980) Am. J. Ophthalmol. , vol.90 , Issue.3 , pp. 360-368
    • Hoffer, K.J.1
  • 26
    • 37349029644 scopus 로고    scopus 로고
    • Interocular axial length difference and age-related cataract
    • Rajan MS, Bunce C, Tuft S. Interocular axial length difference and age-related cataract. J Cataract Refract Surg 2008;34(1):76-79.
    • (2008) J. Cataract Refract. Surg. , vol.34 , Issue.1 , pp. 76-79
    • Rajan, M.S.1    Bunce, C.2    Tuft, S.3
  • 28
    • 33751313879 scopus 로고    scopus 로고
    • Intraocular lens power in bilateral cataract surgery: Whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye
    • Jabbour J, Irwig L, Macaskill P, Hennessy MP. Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye. J Cataract Refract Surg 2006;32(12):2091-2097.
    • (2006) J. Cataract Refract. Surg. , vol.32 , Issue.12 , pp. 2091-2097
    • Jabbour, J.1    Irwig, L.2    Macaskill, P.3    Hennessy, M.P.4
  • 29
    • 0032769681 scopus 로고    scopus 로고
    • Measurement of corneal curvature in young and older normal subjects
    • Pardhan S, Beesley J. Measurement of corneal curvature in young and older normal subjects. J Refract Surg 1999;15(4):469-474.
    • (1999) J. Refract. Surg. , vol.15 , Issue.4 , pp. 469-474
    • Pardhan, S.1    Beesley, J.2
  • 30
    • 41949134115 scopus 로고    scopus 로고
    • Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic
    • Ferrer-Blasco T, Gonzalez-Meijome JM, Montes-Mico R. Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic. J Cataract Refract Surg 2008;34(3):424-432.
    • (2008) J. Cataract Refract. Surg. , vol.34 , Issue.3 , pp. 424-432
    • Ferrer-Blasco, T.1    Gonzalez-Meijome, J.M.2    Montes-Mico, R.3
  • 31
    • 0029995810 scopus 로고    scopus 로고
    • Relationships between preoperative astigmatism and corneal optical power, axial length, intraocular pressure, gender, and patient age
    • Ninn-Pedersen K. Relationships between preoperative astigmatism and corneal optical power, axial length, intraocular pressure, gender, and patient age. J Refract Surg 1996;12(4):472-482.
    • (1996) J. Refract. Surg. , vol.12 , Issue.4 , pp. 472-482
    • Ninn-Pedersen, K.1
  • 33
    • 0032989769 scopus 로고
    • Changes in refractive error over a 5-year interval in the Beaver Dam eye study
    • Lee KE, Klein BEK, Klein R. Changes in refractive error over a 5-year interval in the Beaver Dam eye study. Invest Ophthalmol Vis Sci 1990;40: 1645-1649.
    • (1990) Invest. Ophthalmol. Vis. Sci. , vol.40 , pp. 1645-1649
    • Lee, K.E.1    Klein, B.E.K.2    Klein, R.3
  • 34
    • 0035028157 scopus 로고    scopus 로고
    • The relationship between ocular dimensions and refraction with adult stature: the Tanjong Pagar Survey
    • Wong TY, Foster PJ, Johnson GJ, Klein BE, Seah SK.. The relationship between ocular dimensions and refraction with adult stature: the Tanjong Pagar Survey. Invest Ophthalmol Vis Sci 2001;42(6):1237-1242.
    • (2001) Invest. Ophthalmol. Vis. Sci. , vol.42 , Issue.6 , pp. 1237-1242
    • Wong, T.Y.1    Foster, P.J.2    Johnson, G.J.3    Klein, B.E.4    Seah, S.K.5
  • 35


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.