메뉴 건너뛰기




Volumn , Issue , 2010, Pages 479-485

Processing body sensor data streams for continuous physiological monitoring

Author keywords

Electromyogram; Factor analysis; Fatigue; Feature extraction; Physiological; Wearable sensors

Indexed keywords

BODY SENSOR NETWORK; CONTINUOUS MONITORING; DATA STREAM; DOMAIN KNOWLEDGE; ELECTROMYOGRAM; ELECTROMYOGRAM SIGNALS; FACTOR ANALYSIS; FACTOR ANALYSIS MODEL; FREQUENCY DOMAINS; HAND MOVEMENT; HAND MUSCLES; HIDDEN INFORMATION; HIDDEN KNOWLEDGE; INFORMATION NEED; INTENSITY LEVELS; KNOWLEDGE MANAGEMENT SYSTEM; LATENT FACTOR; MOTOR BEHAVIOR; MUSCLE FATIGUES; ON-BODY; PHYSIOLOGICAL MONITORING; PHYSIOLOGICAL STATE; QUANTITATIVE FEATURES; SENSOR DATA; TIME-SERIES DATA; WEARABLE SENSORS;

EID: 77952398314     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/1743384.1743468     Document Type: Conference Paper
Times cited : (6)

References (20)
  • 2
    • 0019824718 scopus 로고
    • Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts
    • Nov.
    • B. Bigland-Ritchie, E. F. Donovan, and C. S. Roussos. Conduction velocity and EMG power spectrum changes in fatigue of sustained maximal efforts. J Appl Physiol, 51(5):1300-1305, Nov. 1981.
    • (1981) J Appl Physiol , vol.51 , Issue.5 , pp. 1300-1305
    • Bigland-Ritchie, B.1    Donovan, E.F.2    Roussos, C.S.3
  • 3
    • 0032698259 scopus 로고    scopus 로고
    • Detection of hidden rhythms in surface EMG signals with a non-linear time-series tool
    • July
    • G. Filligoi and F. Felici. Detection of hidden rhythms in surface EMG signals with a non-linear time-series tool. Medical Engineering & Physics, 21(6-7):439-448, July 1999.
    • (1999) Medical Engineering & Physics , vol.21 , Issue.6-7 , pp. 439-448
    • Filligoi, G.1    Felici, F.2
  • 5
    • 21544468321 scopus 로고    scopus 로고
    • Classification of emg signals using pca and fft
    • N. F. Güler and S. Ko̧cer. Classification of emg signals using pca and fft. J. Med. Syst., 29(3):241-250, 2005.
    • (2005) J. Med. Syst. , vol.29 , Issue.3 , pp. 241-250
    • Güler, N.F.1    Ko̧cer, S.2
  • 6
    • 0026726635 scopus 로고
    • Interpretation of EMG spectral alterations and alteration indexes at sustained contraction
    • Oct.
    • G. M. Hagg. Interpretation of EMG spectral alterations and alteration indexes at sustained contraction. J Appl Physiol, 73(4):1211-1217, Oct. 1992.
    • (1992) J Appl Physiol , vol.73 , Issue.4 , pp. 1211-1217
    • Hagg., G.M.1
  • 7
    • 0018195538 scopus 로고
    • An optimality criterion for processing electromyographic (emg) signals relating to human locomotion
    • Sept.
    • C. Hershler and M. Milner. An optimality criterion for processing electromyographic (emg) signals relating to human locomotion. IEEE Transactions on Biomedical Engineering, BME-25(5):413-420, Sept. 1978.
    • (1978) IEEE Transactions on Biomedical Engineering , vol.BME-25 , Issue.5 , pp. 413-420
    • Hershler, C.1    Milner, M.2
  • 11
    • 0035119048 scopus 로고    scopus 로고
    • Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. reliability in the context of clinical applications
    • Mar.
    • G. A. Koumantakis, F. Arnall, R. G. Cooper, and J. A. Oldham. Paraspinal muscle EMG fatigue testing with two methods in healthy volunteers. reliability in the context of clinical applications. Clinical Biomechanics, 16(3):263-266, Mar. 2001.
    • (2001) Clinical Biomechanics , vol.16 , Issue.3 , pp. 263-266
    • Koumantakis, G.A.1    Arnall, F.2    Cooper, R.G.3    Oldham, J.A.4
  • 12
    • 0032895111 scopus 로고    scopus 로고
    • Selected techniques for data mining in medicine
    • May
    • N. Lavrac. Selected techniques for data mining in medicine. Artificial Intelligence in Medicine, 16(1):3-23, May 1999.
    • (1999) Artificial Intelligence in Medicine , vol.16 , Issue.1 , pp. 3-23
    • Lavrac, N.1
  • 13
    • 16444376021 scopus 로고    scopus 로고
    • Comparison of trend detection algorithms in the analysis of physiological time-series data
    • W. Melek, Z. Lu, A. Kapps, and W. Fraser. Comparison of trend detection algorithms in the analysis of physiological time-series data. Biomedical Engineering, IEEE Transactions on, 52(4):639-651, 2005.
    • (2005) Biomedical Engineering IEEE Transactions on , vol.52 , Issue.4 , pp. 639-651
    • Melek, W.1    Lu, Z.2    Kapps, A.3    Fraser, W.4
  • 14
    • 0032145167 scopus 로고    scopus 로고
    • Using factor analysis to identify neuromuscular synergies during treadmill walking
    • Aug.
    • L. A. Merkle, C. S. Layne, J. J. Bloomberg, and J. J. Zhang. Using factor analysis to identify neuromuscular synergies during treadmill walking. Journal of Neuroscience Methods, 82(2):207-214, Aug. 1998.
    • (1998) Journal of Neuroscience Methods , vol.82 , Issue.2 , pp. 207-214
    • Merkle, L.A.1    Layne, C.S.2    Bloomberg, J.J.3    Zhang, J.J.4
  • 15
    • 0025641868 scopus 로고
    • Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions
    • Nov.
    • R. Merletti, M. Knaflitz, and C. J. D. Luca. Myoelectric manifestations of fatigue in voluntary and electrically elicited contractions. J Appl Physiol, 69(5):1810-1820, Nov. 1990.
    • (1990) J Appl Physiol , vol.69 , Issue.5 , pp. 1810-1820
    • Merletti, R.1    Knaflitz, M.2    Luca, C.J.D.3
  • 16
    • 21844447139 scopus 로고    scopus 로고
    • Application of higher order statistics techniques to EMG signals to characterize the motor unit action potential
    • S. Shahid, J. Walker, G. Lyons, C. Byrne, and A. Nene. Application of higher order statistics techniques to EMG signals to characterize the motor unit action potential. Biomedical Engineering, IEEE Transactions on, 52(7):1195-1209, 2005.
    • (2005) Biomedical Engineering IEEE Transactions on , vol.52 , Issue.7 , pp. 1195-1209
    • Shahid, S.1    Walker, J.2    Lyons, G.3    Byrne, C.4    Nene, A.5
  • 18
    • 71349088184 scopus 로고    scopus 로고
    • Reliability difference between spectral and entropic measures of erector spinae muscle fatigability
    • In Press, Corrected Proof
    • P. S. Sung, U. Zurcher, and M. Kaufman. Reliability difference between spectral and entropic measures of erector spinae muscle fatigability. Journal of Electromyography and Kinesiology, In Press, Corrected Proof.
    • Journal of Electromyography and Kinesiology
    • Sung, P.S.1    Zurcher, U.2    Kaufman, M.3
  • 19
    • 0021251846 scopus 로고
    • Pathologic gait diagnosis with computer averaged electromyographic profiles
    • Sept.
    • D. Winter. Pathologic gait diagnosis with computer averaged electromyographic profiles. Arch. Phys. Med. Rehab., 65:393-398, Sept. 1984.
    • (1984) Arch. Phys. Med. Rehab. , vol.65 , pp. 393-398
    • Winter, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.