메뉴 건너뛰기




Volumn 84, Issue 4, 2010, Pages 668-672

Influence of the diameter of monolithic capillary columns on their gas chromatography characteristics

Author keywords

[No Author keywords available]

Indexed keywords

C PARAMETER; LIGHT HYDROCARBON; LITERATURE DATA; MICROCOLUMNS; MONOLITHIC CAPILLARY COLUMN; MONOLITHIC COLUMNS; N-BUTANE; PACKED CAPILLARY COLUMNS; SEPARATION PROPERTY; SORBATES; TEST MIXTURES; VAN DEEMTER EQUATION;

EID: 77952387334     PISSN: 00360244     EISSN: None     Source Type: Journal    
DOI: 10.1134/S0036024410040254     Document Type: Article
Times cited : (1)

References (11)
  • 3
    • 77952326500 scopus 로고    scopus 로고
    • LECO Corporation, GCxGC FID/ECD, Form No. 209-157
    • LECO Corporation, GCxGC FID/ECD, Form No. 209-157 (www.leco.com).
  • 7
    • 0030298087 scopus 로고    scopus 로고
    • Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separation of polymers Comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in high-performance liquid chromatography of polystyrenes
    • DOI 10.1016/S0021-9673(96)00510-9, PII S0021967396005109
    • M. Petro F. Svec J. Frechet 1996 J. Chromatogr. A 752 59 10.1016/S0021-9673(96)00510-9 1:CAS:528:DyaK28XnsFShtLw%3D (Pubitemid 26396479)
    • (1996) Journal of Chromatography A , vol.752 , Issue.1-2 , pp. 59-66
    • Petro, M.1    Svec, F.2    Frechet, J.M.J.3
  • 8
    • 33947186309 scopus 로고    scopus 로고
    • Comparison between monolithic conventional size, microbore and capillary poly(p-methylstyrene-co-1,2-bis(p-vinylphenyl)ethane) high-performance liquid chromatography columns. Synthesis, application, long-term stability and reproducibility
    • DOI 10.1016/j.chroma.2007.02.004, PII S0021967307002592
    • L. Trojer S. H. Lubbad C. P. Bisjak, et al. 2007 J. Chromatogr. A 1146 216 10.1016/j.chroma.2007.02.004 1:CAS:528:DC%2BD2sXjtVamt7w%3D (Pubitemid 46400728)
    • (2007) Journal of Chromatography A , vol.1146 , Issue.2 , pp. 216-224
    • Trojer, L.1    Lubbad, S.H.2    Bisjak, C.P.3    Wieder, W.4    Bonn, G.K.5
  • 9
    • 0037172868 scopus 로고    scopus 로고
    • Repeatability and reproducibility of retention data and band profiles on six batches of monolithic columns
    • DOI 10.1016/S0021-9673(01)01227-4, PII S0021967301012274
    • M. Kele G. Guiochon 2002 J. Chromatogr. A 960 19 10.1016/S0021-9673(01) 01227-4 1:CAS:528:DC%2BD38XksFKgsrY%3D (Pubitemid 34663739)
    • (2002) Journal of Chromatography A , vol.960 , Issue.1-2 , pp. 19-49
    • Kele, M.1    Guiochon, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.