메뉴 건너뛰기




Volumn 27, Issue , 2010, Pages 1-5

Challenges and opportunities of ultra-high field MRI

Author keywords

MRI; MRS; Neuroimaging; Ultra high field

Indexed keywords

BIOMEDICAL ENGINEERING; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; NEUROIMAGING; PHOTODEGRADATION;

EID: 77952371097     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-12020-6_1     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 3
    • 0035217653 scopus 로고    scopus 로고
    • High-resolution BOLD venographic imaging: A window into brain function
    • Reichenbach JR, Haacke EM. (2001) High-resolution BOLD venographic imaging: a window into brain function. NMR in Biomedicine. 14:453-467.
    • (2001) NMR in Biomedicine , vol.14 , pp. 453-467
    • Reichenbach, J.R.1    Haacke, E.M.2
  • 4
    • 0030981629 scopus 로고    scopus 로고
    • Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent
    • Reichenbach JR, Venkatesan R, Schillinger DJ, Kido DK, Haacke EM. (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology. 204:272-277. (Pubitemid 27281745)
    • (1997) Radiology , vol.204 , Issue.1 , pp. 272-277
    • Reichenbach, J.R.1    Venkatesan, R.2    Schillinger, D.J.3    Kido, D.K.4    Haacke, E.M.5
  • 5
    • 0033759178 scopus 로고    scopus 로고
    • Artery and vein separation using susceptibility-dependent phase in contrast-enhanced MRA
    • Wang Y, Yu Y, Li D, et al. (2000) Artery and vein separation using susceptibility-dependent phase in contrast-enhanced MRA. Journal of Magnetic Resonance Imaging. 12:661-670.
    • (2000) Journal of Magnetic Resonance Imaging , vol.12 , pp. 661-670
    • Wang, Y.1    Yu, Y.2    Li, D.3
  • 6
    • 64649090409 scopus 로고    scopus 로고
    • First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: Comparison of 1.5T and 7T
    • Kollia K, Maderwald S, Putzki N, et al. (2009) First clinical study on ultra-high-field MR imaging in patients with multiple sclerosis: comparison of 1.5T and 7T. American Journal of Neuroradiology. 30:699-702.
    • (2009) American Journal of Neuroradiology , vol.30 , pp. 699-702
    • Kollia, K.1    Maderwald, S.2    Putzki, N.3
  • 7
    • 77952329588 scopus 로고    scopus 로고
    • 7-Tesla MRI Improves the Detection of Cortical Lesions in Multiple Sclerosis
    • Tallantyre EC, Morgan PS, Dixon JE, et al. (2009) 7-Tesla MRI Improves the Detection of Cortical Lesions in Multiple Sclerosis. Neurology. 72:A269-A269.
    • (2009) Neurology , vol.72
    • Tallantyre, E.C.1    Morgan, P.S.2    Dixon, J.E.3
  • 8
    • 70350705712 scopus 로고    scopus 로고
    • A compatison of 3T and 7T in the detection of small parenchymal veins within MS lesions
    • Tallantyre EC, Morgan PS, Dixon JE, et al. (2009) A compatison of 3T and 7T in the detection of small parenchymal veins within MS lesions. Investigative Radiology. 44:491-494.
    • (2009) Investigative Radiology , vol.44 , pp. 491-494
    • Tallantyre, E.C.1    Morgan, P.S.2    Dixon, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.