메뉴 건너뛰기




Volumn 114, Issue 19, 2010, Pages 5967-5979

High-accuracy measurements of OH reaction rate constants and IR absorption spectra: CH2 - CF-CF3 and trans -CHF - CH-CF3

Author keywords

[No Author keywords available]

Indexed keywords

ATMOSPHERIC LIFETIME; CONFIDENCE LEVELS; FLASH PHOTOLYSIS; FLUORESCENCE TECHNIQUE; GAS-PHASE REACTIONS; GLOBAL WARMING POTENTIAL; HIGH-ACCURACY MEASUREMENTS; IR ABSORPTION; IR ABSORPTION SPECTRA; OH RADICAL; OH REACTION; TEMPERATURE DEPENDENCE; TEMPERATURE INTERVALS; TEMPERATURE RANGE;

EID: 77952361652     PISSN: 10895639     EISSN: 15205215     Source Type: Journal    
DOI: 10.1021/jp9092817     Document Type: Article
Times cited : (48)

References (46)
  • 4
    • 77952402924 scopus 로고    scopus 로고
    • (Intergovernmental Panel on Climate Change). Houghton, J. T.; Jenkins, G. J.; Ephraums, J. J., Eds.; Cambridge University Press: Cambridge, UK
    • (Intergovernmental Panel on Climate Change). Climate Change. The IPCC Scientific Assessment., Houghton, J. T.; Jenkins, G. J.; Ephraums, J. J., Eds.; Cambridge University Press: Cambridge, UK, 365 pp.
    • Climate Change. The IPCC Scientific Assessment , pp. 365
  • 6
    • 0003490075 scopus 로고
    • World Meteorological Organization, Global Ozone Research and Monitoring Project - Report No. 20, Appendix: AFEAS Report; World Meteorological Organization: Geneva
    • Scientific Assessment of Stratospheric Ozone: 1989, World Meteorological Organization, Global Ozone Research and Monitoring Project-Report No. 20, Appendix: AFEAS Report; World Meteorological Organization: Geneva, 1989; Vol 2.
    • (1989) Scientific Assessment of Stratospheric Ozone: 1989 , vol.2
  • 15
    • 77952405298 scopus 로고    scopus 로고
    • Certain commercial equipment, instruments, or materials are identified in this article in order to adequately specify the experimental procedure. Such identification does not imply recognition or endorsement by the National Institute of Standards and Technology, nor does it imply that the material or equipment identified are necessarily the best available for the purpose
    • Certain commercial equipment, instruments, or materials are identified in this article in order to adequately specify the experimental procedure. Such identification does not imply recognition or endorsement by the National Institute of Standards and Technology, nor does it imply that the material or equipment identified are necessarily the best available for the purpose.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.