Volumn 36, Issue 5, 2010, Pages 802-813

Improving the robustness of time-of-flight based shear wave speed reconstruction methods using RANSAC in human liver in vivo

Author keywords

Acoustic radiation force; Hepatic fibrosis; Shear wave; Stiffness; Ultrasound

Indexed keywords

ACCURACY AND PRECISION; ACOUSTIC RADIATION FORCE; ANTARES; BUSINESS UNITS; CLINICAL SETTINGS; DIAGNOSTIC ACCURACY; ESTIMATION METHODS; GROSS OUTLIERS; HEPATIC FIBROSIS; HUMAN LIVER; HUMAN PATIENTS; IN-VIVO; LIVER STIFFNESS; MEAN ERRORS; MODEL FITTING; ORDINARY LEAST SQUARES; PHYSIOLOGIC MOTION; RADIATION FORCES; RANDOM SAMPLE CONSENSUS; REALTIME IMAGING; RECONSTRUCTION ACCURACY; RECONSTRUCTION METHOD; SHEAR MODULUS; SHEAR STIFFNESS; SHEAR WAVE SPEED; SIEMENS; SOFT TISSUE; SPATIAL INHOMOGENEITIES; STANDARD DEVIATION; STIFFNESS MEASUREMENTS; TIME OF FLIGHT; TIME-OF-FLIGHT METHOD; TISSUE DISPLACEMENT; TISSUE STIFFNESS; ULTRASOUND SYSTEM;

EID: 77952320923     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2010.02.007     Document Type: Article
Times cited : (112)

References (22)
  • 2
    • 2942672243 scopus 로고    scopus 로고
    • Quantifying elasticity and viscosity from measurement of shear wave speed dispersion
    • Chen S., Fatemi M., Greenleaf J.F. Quantifying elasticity and viscosity from measurement of shear wave speed dispersion. J Acoust Soc Am 2004, 115:2781-2785.
    • (2004) J Acoust Soc Am , vol.115 , pp. 2781-2785
    • Chen, S.1    Fatemi, M.2    Greenleaf, J.F.3
  • 5
    • 61449131569 scopus 로고    scopus 로고
    • Shear wave spectroscopy for in vivo quantification of human soft tissues viscoelasticity
    • Deffieux T., Montaldo G., Tanter M., Fink M. Shear wave spectroscopy for in vivo quantification of human soft tissues viscoelasticity. IEEE Trans Med Imaging 2009, 28:313-322.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 313-322
    • Deffieux, T.1    Montaldo, G.2    Tanter, M.3    Fink, M.4
  • 6
    • 0019574599 scopus 로고
    • Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography
    • Fischler M.A., Bolles R.C. Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 1981, 24:381-395.
    • (1981) Commun ACM , vol.24 , pp. 381-395
    • Fischler, M.A.1    Bolles, R.C.2
  • 9
    • 34447255876 scopus 로고    scopus 로고
    • Shear-modulus estimation by application of spatially modulated impulsive acoustic radiation force
    • McAleavey S.A., Menon M., Orszulak J. Shear-modulus estimation by application of spatially modulated impulsive acoustic radiation force. Ultrason Imaging 2007, 29:87-104.
    • (2007) Ultrason Imaging , vol.29 , pp. 87-104
    • McAleavey, S.A.1    Menon, M.2    Orszulak, J.3
  • 10
    • 33645275457 scopus 로고    scopus 로고
    • Shear wave speed recovery in transient elastography and supersonic imaging using propagating fronts
    • McLaughlin J., Renzi D. Shear wave speed recovery in transient elastography and supersonic imaging using propagating fronts. Inverse Problems 2006, 22:681-706.
    • (2006) Inverse Problems , vol.22 , pp. 681-706
    • McLaughlin, J.1    Renzi, D.2
  • 11
    • 58649122872 scopus 로고    scopus 로고
    • Quantitative viscoelasticity mapping of human liver using supersonic shear imaging: Preliminary in vivo feasibility study
    • Muller M., Gennisson J.L., Deffieux T., Tanter M., Fink M. Quantitative viscoelasticity mapping of human liver using supersonic shear imaging: Preliminary in vivo feasibility study. Ultrasound Med Biol 2009, 35:219-229.
    • (2009) Ultrasound Med Biol , vol.35 , pp. 219-229
    • Muller, M.1    Gennisson, J.L.2    Deffieux, T.3    Tanter, M.4    Fink, M.5
  • 12
    • 0347123252 scopus 로고    scopus 로고
    • Shear-wave generation using acoustic radiation force: in vivo and ex vivo results
    • Nightingale K., McAleavey S., Trahey G. Shear-wave generation using acoustic radiation force: in vivo and ex vivo results. Ultrasound Med Biol 2003, 29:1715-1723.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1715-1723
    • Nightingale, K.1    McAleavey, S.2    Trahey, G.3
  • 13
    • 0035146230 scopus 로고    scopus 로고
    • Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation
    • Oliphant T.E., Manduca A., Ehman R.L., Greenleaf J.F. Complex-valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation. Magn Reson Med 2001, 45:299-310.
    • (2001) Magn Reson Med , vol.45 , pp. 299-310
    • Oliphant, T.E.1    Manduca, A.2    Ehman, R.L.3    Greenleaf, J.F.4
  • 19
    • 17044414054 scopus 로고    scopus 로고
    • Viscoelastic shear properties of in vivo breast lesions measured by mr elastography
    • Sinkus R., Tanter M., Xydeas T., Catheline S., Bercoff J., Fink M. Viscoelastic shear properties of in vivo breast lesions measured by mr elastography. Magn Reson Imaging 2005, 23:159-165.
    • (2005) Magn Reson Imaging , vol.23 , pp. 159-165
    • Sinkus, R.1    Tanter, M.2    Xydeas, T.3    Catheline, S.4    Bercoff, J.5    Fink, M.6
  • 21
    • 0033894631 scopus 로고    scopus 로고
    • A new robust estimator with application to estimating image geometry
    • Torr P.H.S., Zisserman A.M.L.E.S.A.C. A new robust estimator with application to estimating image geometry. Comput Vis Image Underst 2000, 78:138-156.
    • (2000) Comput Vis Image Underst , vol.78 , pp. 138-156
    • Torr, P.H.S.1    Zisserman, A.M.L.E.S.A.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.