메뉴 건너뛰기




Volumn 59, Issue 6, 2010, Pages 1507-1519

A multisensor intelligent device for real-time multiphase flow metering in oil fields

Author keywords

Artificial intelligence; Capacitance and conductance probes; Embedded systems design; Gas flow rate measurement; Multiphase flow metering; Neural network; Ultrasonic waves; Water cut measurement

Indexed keywords

CONDUCTANCE PROBE; EMBEDDED SYSTEMS DESIGN; GAS FLOWRATE;

EID: 77952291053     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2009.2028210     Document Type: Article
Times cited : (51)

References (23)
  • 1
    • 77952292228 scopus 로고    scopus 로고
    • An industrial-prototype acoustic array for real-time emulsion layer detection in oil storage tanks
    • to be published
    • M. M. A. Al-Naamani and K. Al-Busaidi, "An industrial-prototype acoustic array for real-time emulsion layer detection in oil storage tanks," IEEE Trans. Instrum. Meas., 2009. to be published.
    • (2009) IEEE Trans. Instrum. Meas.
    • Al-Naamani, M.M.A.1    Al-Busaidi, K.2
  • 2
    • 33645701073 scopus 로고    scopus 로고
    • Intelligent system for process supervision and fault diagnostic in dynamic physical systems
    • Apr.
    • C. H. Lo, Y. K. Wong, and A. B. Rad, "Intelligent system for process supervision and fault diagnostic in dynamic physical systems," IEEE Trans. Ind. Electron., vol.53, no.2, pp. 581-592, Apr. 2006.
    • (2006) IEEE Trans. Ind. Electron. , vol.53 , Issue.2 , pp. 581-592
    • Lo, C.H.1    Wong, Y.K.2    Rad, A.B.3
  • 4
    • 67949094911 scopus 로고    scopus 로고
    • A review of multiphase flowmeters and future development potential
    • Seoul, Korea, Oct.
    • T. S. Whitaker, "A review of multiphase flowmeters and future development potential," in Proc. 6th Int. Conf. FLOMEKO, Seoul, Korea, Oct. 2005, pp. 628-634.
    • (2005) Proc. 6th Int. Conf. FLOMEKO , pp. 628-634
    • Whitaker, T.S.1
  • 5
    • 47049099369 scopus 로고    scopus 로고
    • An FPGA implementation of a digital Coriolis mass flow metering drive system
    • Jul.
    • M. Zamora, "An FPGA implementation of a digital Coriolis mass flow metering drive system," IEEE Trans. Ind. Electron., vol.55, no.7, pp. 2820-2831, Jul. 2008.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , Issue.7 , pp. 2820-2831
    • Zamora, M.1
  • 6
    • 0020748982 scopus 로고
    • Application of microprocessor to fuel measurement system
    • May
    • D. D'Aessandro, "Application of microprocessor to fuel measurement system," IEEE Trans. Ind. Electron., vol.IE-30, no.2, pp. 164-170, May 1983.
    • (1983) IEEE Trans. Ind. Electron. , vol.IE-30 , Issue.2 , pp. 164-170
    • D'Aessandro, D.1
  • 7
    • 77952292707 scopus 로고
    • Toyota's new microprocessor-based diesel engine control for passenger cars
    • Nov.
    • M. Kawai, H. Miyagi, J. Nakano, and Y. Kondo, "Toyota's new microprocessor-based diesel engine control for passenger cars," IEEE Trans. Ind. Electron., vol.32, no.4, pp. 289-293, Nov. 1995.
    • (1995) IEEE Trans. Ind. Electron. , vol.32 , Issue.4 , pp. 289-293
    • Kawai, M.1    Miyagi, H.2    Nakano, J.3    Kondo, Y.4
  • 8
    • 0022721026 scopus 로고
    • Ultrasonic flow velocity sensor based on picosecond timing system
    • May
    • P. K. Chande, "Ultrasonic flow velocity sensor based on picosecond timing system," IEEE Trans. Ind. Electron., vol.IE-33, no.2, pp. 162-165, May 1986.
    • (1986) IEEE Trans. Ind. Electron. , vol.IE-33 , Issue.2 , pp. 162-165
    • Chande, P.K.1
  • 11
    • 85015514469 scopus 로고    scopus 로고
    • Two phase flow measurement with orifices
    • Dec.
    • J. W. Murdock, "Two phase flow measurement with orifices," Trans. ASME, J. Basic Eng., vol.84, pp. 419-433, Dec. 2006.
    • (2006) Trans. ASME, J. Basic Eng. , vol.84 , pp. 419-433
    • Murdock, J.W.1
  • 14
    • 46249126945 scopus 로고    scopus 로고
    • Measurement of two-phase flow rate based on slotted orifice couple and neural network ensemble
    • G. Yanfeng, Z. Jinwu, and S. Gang, "Measurement of two-phase flow rate based on slotted orifice couple and neural network ensemble," in Proc. IEEE Int. Conf. Inf. Acquisition, 2006, pp. 1037-1041.
    • (2006) Proc. IEEE Int. Conf. Inf. Acquisition , pp. 1037-1041
    • Yanfeng, G.1    Jinwu, Z.2    Gang, S.3
  • 16
    • 0033308941 scopus 로고    scopus 로고
    • Development of a high speed X-ray tomography system for multiphase flow imaging
    • Jun.
    • E. J. Morton, R. D. Luggar, M. J. Key, A. Kundu, L. M. N. Tavora, and W. B. Gilboy, "Development of a high speed X-ray tomography system for multiphase flow imaging," IEEE Trans. Nucl. Sci., vol.46, no.3, pp. 380-384, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 380-384
    • Morton, E.J.1    Luggar, R.D.2    Key, M.J.3    Kundu, A.4    Tavora, L.M.N.5    Gilboy, W.B.6
  • 17
    • 16444381711 scopus 로고    scopus 로고
    • Application of conventional-and dual-energy X-ray tomography in process engineering
    • Apr.
    • S. Gehrke and K.-E.Wirth, "Application of conventional-and dual-energy X-ray tomography in process engineering," IEEE Sensors J., vol.5, no.2, pp. 183-187, Apr. 2005.
    • (2005) IEEE Sensors J. , vol.5 , Issue.2 , pp. 183-187
    • Gehrke, S.1    Wirth, K.-E.2
  • 18
    • 34047196983 scopus 로고    scopus 로고
    • Analysis of performance and capacitance sensitivity distributions of sensor for electrical capacitance tomography system
    • DOI 10.1109/WCICA.2006.1713334, 1713334, Proceedings of the World Congress on Intelligent Control and Automation (WCICA)
    • L. Sun, D. Chen, and G. Zheng, "Analysis of performance and capacitance sensitivity distributions of sensor for electrical capacitance tomography system," in Proc. 6th WCICA, 2006, vol.1, pp. 4977-4981. (Pubitemid 46533753)
    • (2006) Proceedings of the World Congress on Intelligent Control and Automation (WCICA) , vol.1 , pp. 4977-4981
    • Sun, L.1    Chen, D.2    Zheng, G.3
  • 19
    • 0034476423 scopus 로고    scopus 로고
    • The use of a coaxial capacitor as a capacitance sensor for phase percentage determination in multiphase pipelines
    • S. I. Al-Mously and A. Y. Ahmed, "The use of a coaxial capacitor as a capacitance sensor for phase percentage determination in multiphase pipelines," in Proc. 10th MELECON, 2000, vol.2, pp. 742-745.
    • (2000) Proc. 10th MELECON , vol.2 , pp. 742-745
    • Al-Mously, S.I.1    Ahmed, A.Y.2
  • 20
    • 33947385783 scopus 로고    scopus 로고
    • Hardware implementation of a real-time neural network controller with a DSP and an FPGA for nonlinear systems
    • Feb.
    • S. Jung and S. su Kim, "Hardware implementation of a real-time neural network controller with a DSP and an FPGA for nonlinear systems," IEEE Trans. Ind. Electron., vol.54, no.1, pp. 265-271, Feb. 2007.
    • (2007) IEEE Trans. Ind. Electron. , vol.54 , Issue.1 , pp. 265-271
    • Jung, S.1    Kim, S.S.2
  • 21
    • 4444270297 scopus 로고    scopus 로고
    • Terahertz process tomography using in multiphase flow measurement
    • J. Chen, Z. Zhou, X. Zhang, and T. Yu, "Terahertz process tomography using in multiphase flow measurement," in Proc. WCICA, 2004, pp. 3727-3729.
    • (2004) Proc. WCICA , pp. 3727-3729
    • Chen, J.1    Zhou, Z.2    Zhang, X.3    Yu, T.4
  • 23
    • 33947370279 scopus 로고    scopus 로고
    • A pulsed neural network with onchip learning and its practical applications
    • Feb.
    • H. Zhuang, K.-S. Low, andW.-Y. Yau, "A pulsed neural network with onchip learning and its practical applications," IEEE Trans. Ind. Electron., vol.54, no.1, pp. 34-42, Feb. 2007.
    • (2007) IEEE Trans. Ind. Electron. , vol.54 , Issue.1 , pp. 34-42
    • Zhuang, H.1    Low, K.-S.2    Yau, W.-Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.