메뉴 건너뛰기




Volumn 26, Issue 5, 2010, Pages 361-363

Endotracheal tube cuff pressures in pediatric patients intubated before aeromedical transport

Author keywords

Aeromedical transport; Airway; Emergency medical service; Endotracheal cuff pressure

Indexed keywords

ADOLESCENT; AIR MEDICAL TRANSPORT; ARTICLE; CHILD; CONTROLLED STUDY; DEMOGRAPHY; EMERGENCY HEALTH SERVICE; EMERGENCY WARD; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; ENDOTRACHEAL TUBE CUFF PRESSURE; FEMALE; HUMAN; INCIDENCE; INFANT; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; MANOMETRY; PRESSURE MEASUREMENT; RISK ASSESSMENT; COMPARATIVE STUDY; EQUIPMENT DESIGN; PRESCHOOL CHILD; PRESSURE; PROSPECTIVE STUDY; REPRODUCIBILITY; RISK FACTOR; TRACHEAL DISEASES; ULCER;

EID: 77952288202     PISSN: 07495161     EISSN: None     Source Type: Journal    
DOI: 10.1097/PEC.0b013e3181db224d     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 13644258050 scopus 로고    scopus 로고
    • Endotracheal tube pressure in three hospitals, and the volume required to produce an appropriate cuff pressure
    • Sengupta P, Sessler D, Maglinger P, et al. Endotracheal tube pressure in three hospitals, and the volume required to produce an appropriate cuff pressure. BMC Anesthesiol. 2004;4:8.
    • (2004) BMC Anesthesiol , vol.4 , pp. 8
    • Sengupta, P.1    Sessler, D.2    Maglinger, P.3
  • 2
    • 0026766916 scopus 로고
    • Sore throat after endotracheal intubation
    • Mandoe H, Nikolajsen L, Lintrup U, et al. Sore throat after endotracheal intubation. Anesth Analg. 1992;74:897-900.
    • (1992) Anesth. Analg. , vol.74 , pp. 897-900
    • Mandoe, H.1    Nikolajsen, L.2    Lintrup, U.3
  • 3
    • 0017342383 scopus 로고
    • Blood flow in the rabbit tracheal mucosa under normal conditions and under the influence of tracheal intubation
    • Nordin U, Lindholm CE, Wolgast M. Blood flow in the rabbit tracheal mucosa under normal conditions and under the influence of tracheal intubation. Acta Anaesthesiol Scand. 1977;21:81-94.
    • (1977) Acta Anaesthesiol Scand. , vol.21 , pp. 81-94
    • Nordin, U.1    Lindholm, C.E.2    Wolgast, M.3
  • 4
    • 0021260456 scopus 로고
    • Endotracheal cuff pressure and tracheal mucosal blood flow: Endoscopic study of effects of four large volume cuffs
    • Seegobin RD, van Hesselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed). 1984;288:965-968.
    • (1984) Br. Med. J. (Clin Res. Ed) , vol.288 , pp. 965-968
    • Seegobin, R.D.1    Van Hesselt, G.L.2
  • 5
    • 0017357049 scopus 로고
    • The trachea and cuff induced tracheal injury: An experimental study on causative factors and prevention
    • Nordin U. The trachea and cuff induced tracheal injury: an experimental study on causative factors and prevention. Acta Otolaryngol. 1976; 345 (suppl 345) : 1-7.
    • (1976) Acta Otolaryngol , vol.345 , Issue.345 SUPPL. , pp. 1-7
    • Nordin, U.1
  • 6
    • 33845186646 scopus 로고    scopus 로고
    • Endotracheal intracuff pressures in the ED and prehospital setting: Is there a problem?
    • Svenson J, Lindsay M, O'Connor J. Endotracheal intracuff pressures in the ED and prehospital setting: is there a problem? Am J Emerg Med. 2007;25:53-56.
    • (2007) Am. J. Emerg. Med. , vol.25 , pp. 53-56
    • Svenson, J.1    Lindsay, M.2    O'Connor, J.3
  • 7
    • 70349190329 scopus 로고    scopus 로고
    • Endotracheal tube cuff pressures in patients intubated before transport
    • Chapman J, Pallin D, Ferrara L, et al. Endotracheal tube cuff pressures in patients intubated before transport. Am J Emerg Med. 2009; 27 (8) : 980-982.
    • (2009) Am. J. Emerg. Med. , vol.27 , Issue.8 , pp. 980-982
    • Chapman, J.1    Pallin, D.2    Ferrara, L.3
  • 8
    • 0025677458 scopus 로고
    • Endotracheal tube cuff pressure assessment: Pitfalls of finger estimation and need for objective measurement
    • Fernandez R, Blanch L, Mancebo J, et al. Endotracheal tube cuff pressure assessment: pitfalls of finger estimation and need for objective measurement. Crit Care Med. 1990;18:1423-1426.
    • (1990) Crit. Care Med. , vol.18 , pp. 1423-1426
    • Fernandez, R.1    Blanch, L.2    Mancebo, J.3
  • 9
    • 0033523796 scopus 로고    scopus 로고
    • Endotracheal tube cuff pressure: Need for precise measurement
    • Braz JR, Navarro LH, Takata IH, et al. Endotracheal tube cuff pressure: need for precise measurement. Sao Paulo Med J. 1999;17:243-247.
    • (1999) Sao Paulo Med. J. , vol.17 , pp. 243-247
    • Braz, J.R.1    Navarro, L.H.2    Takata, I.H.3
  • 10
    • 34447124491 scopus 로고    scopus 로고
    • Practicing paramedics cannot generate or estimate safe endotracheal tube cuff pressure using standard techniques
    • Parwani V, Hoffman R, Russell Bharel C, et al. Practicing paramedics cannot generate or estimate safe endotracheal tube cuff pressure using standard techniques. Prehosp Emerg Care. 2007; 11 (3) : 307-311.
    • (2007) Prehosp Emerg. Care , vol.11 , Issue.3 , pp. 307-311
    • Parwani, V.1    Hoffman, R.2    Bharel, C.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.