메뉴 건너뛰기




Volumn 29, Issue 3, 2010, Pages 25-36

Wearable sensors and systems

Author keywords

[No Author keywords available]

Indexed keywords

AMBULANCE SERVICES; BALANCE DISORDERS; BALANCE TRAINING; CELL PHONE; DATA LOGGER; EMERGENCY SITUATION; HAND MOVEMENT; HEART RATES; LONG TERM MONITORING; MOTION SENSORS; PHYSIOLOGICAL RESPONSE; PRIMARY CARE; REMOTE ACCESS; RESPIRATORY RATE; SENSORIZED GLOVE; WEARABLE SENSORS; WEARABLE TECHNOLOGY;

EID: 77952254293     PISSN: 07395175     EISSN: None     Source Type: Journal    
DOI: 10.1109/MEMB.2010.936554     Document Type: Article
Times cited : (332)

References (65)
  • 1
    • 0141834008 scopus 로고    scopus 로고
    • Wearable sensors/systems and their impact on biomedical engineering
    • May-June
    • P. Bonato, ''Wearable sensors/systems and their impact on biomedical engineering,'' IEEE Eng. Med. Biol. Mag., vol.22, pp. 18-20, May-June 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , pp. 18-20
    • Bonato, P.1
  • 2
    • 0141610986 scopus 로고    scopus 로고
    • The next era of examination and management of the patient with cardiovascular disease
    • May-June
    • P. F. Binkley, ''The next era of examination and management of the patient with cardiovascular disease,'' IEEE Eng. Med. Biol. Mag., vol.22, pp. 23-24, May-June 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , pp. 23-24
    • Binkley, P.F.1
  • 6
    • 77952253705 scopus 로고    scopus 로고
    • SHIMMER [Online]. Available
    • SHIMMER [Online]. Available: http://docs.tinyos.net/index.php/SHIMMER
  • 7
    • 0034968268 scopus 로고    scopus 로고
    • Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
    • July
    • S. Rhee, B. H. Yang, and H. H. Asada, ''Artifact-resistant power-efficient design of finger-ring plethysmographic sensors,'' IEEE Trans. Biomed. Eng., vol.48, pp. 795-805, July 2001.
    • (2001) IEEE Trans. Biomed. Eng. , vol.48 , pp. 795-805
    • Rhee, S.1    Yang, B.H.2    Asada, H.H.3
  • 9
    • 39849106483 scopus 로고    scopus 로고
    • Multichannel reflective PPG earpiece sensor with passive motion cancellation
    • L. Wang, B. P. L. Lo, and G. Z. Yang, ''Multichannel reflective PPG earpiece sensor with passive motion cancellation,'' IEEE Trans. Biomed. Circuits Syst., vol.1, no.4, pp. 235-241, 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst. , vol.1 , Issue.4 , pp. 235-241
    • Wang, L.1    Lo, B.P.L.2    Yang, G.Z.3
  • 11
    • 3042755016 scopus 로고    scopus 로고
    • Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices
    • June
    • K. G. Ng, C. M. Ting, J. H. Yeo, K. W. Sim, W. L. Peh, N. H. Chua, N. K. Chua, and F. Kwong, ''Progress on the development of the MediWatch ambulatory blood pressure monitor and related devices,'' Blood Press. Monit., vol.9, pp. 149-165, June 2004.
    • (2004) Blood Press. Monit. , vol.9 , pp. 149-165
    • Ng, K.G.1    Ting, C.M.2    Yeo, J.H.3    Sim, K.W.4    Peh, W.L.5    Chua, N.H.6    Chua, N.K.7    Kwong, F.8
  • 12
    • 33846906776 scopus 로고    scopus 로고
    • Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time
    • C. C. Poon and Y. T. Zhang, ''Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time,'' Conf. Proc. IEEE Eng. Med. Biol. Soc., vol.6, pp. 5877-5880, 2005.
    • (2005) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.6 , pp. 5877-5880
    • Poon, C.C.1    Zhang, Y.T.2
  • 13
    • 67349123710 scopus 로고    scopus 로고
    • An evaluation of the cuffless blood pressure estimation based on pulse transit time technique: A half-year study on normotensive subjects
    • Mar.
    • M. Y. Wong, C. C. Poon, and Y. T. Zhang, ''An evaluation of the cuffless blood pressure estimation based on pulse transit time technique: A half-year study on normotensive subjects,'' Cardiovasc. Eng., vol.9, pp. 32-38, Mar. 2009.
    • (2009) Cardiovasc. Eng. , vol.9 , pp. 32-38
    • Wong, M.Y.1    Poon, C.C.2    Zhang, Y.T.3
  • 14
    • 26444563443 scopus 로고    scopus 로고
    • Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation
    • Sept.
    • D. Roetenberg, H. J. Luinge, C. T. Baten, and P. H. Veltink, ''Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation,'' IEEE Trans. Neural Syst. Rehabil. Eng., vol.13, pp. 395- 405, Sept. 2005.
    • (2005) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.13 , pp. 395-405
    • Roetenberg, D.1    Luinge, H.J.2    Baten, C.T.3    Veltink, P.H.4
  • 15
    • 0037232943 scopus 로고    scopus 로고
    • Ultra-wideband radio technology: Overview and future research
    • W. Hirt, ''Ultra-wideband radio technology: Overview and future research,'' Comput. Commun., vol.26, no.1, pp. 46-52, 2003.
    • (2003) Comput. Commun. , vol.26 , Issue.1 , pp. 46-52
    • Hirt, W.1
  • 16
    • 15544364450 scopus 로고    scopus 로고
    • Bluetooth telemedicine processor for multichannel biomedical signal transmission via mobile cellular networks
    • Mar.
    • M. F. Rasid and B. Woodward, ''Bluetooth telemedicine processor for multichannel biomedical signal transmission via mobile cellular networks,'' IEEE Trans. Inf. Technol. Biomed., vol.9, pp. 35-43, Mar. 2005.
    • (2005) IEEE Trans. Inf. Technol. Biomed. , vol.9 , pp. 35-43
    • Rasid, M.F.1    Woodward, B.2
  • 17
    • 18244373181 scopus 로고    scopus 로고
    • A wireless body area network of intelligent motion sensors for computer-assisted physical rehabilitation
    • Mar. 1
    • E. Jovanov, A. Milenkovic, C. Otto, and P. C. De Groen, ''A wireless body area network of intelligent motion sensors for computer-assisted physical rehabilitation,'' J. Neuroeng. Rehabil., vol.2, p. 6, Mar. 1, 2005.
    • (2005) J. Neuroeng. Rehabil. , vol.2 , pp. 6
    • Jovanov, E.1    Milenkovic, A.2    Otto, C.3    De Groen, P.C.4
  • 19
    • 0032616456 scopus 로고    scopus 로고
    • The Wearable Motherboard: A flexible information infrastructure or sensate liner for medical applications
    • S. Park, C. Gopalsamy, R. Rajamanickam, and S. Jayaraman, ''The Wearable Motherboard: A flexible information infrastructure or sensate liner for medical applications,'' Stud. Health Technol. Inform., vol.62, pp. 252-258, 1999.
    • (1999) Stud. Health Technol. Inform. , vol.62 , pp. 252-258
    • Park, S.1    Gopalsamy, C.2    Rajamanickam, R.3    Jayaraman, S.4
  • 20
    • 0141499236 scopus 로고    scopus 로고
    • Enhancing the quality of life through wearable technology
    • May-June
    • S. Park and S. Jayaraman, ''Enhancing the quality of life through wearable technology,'' IEEE Eng. Med. Biol. Mag., vol.22, pp. 41-48, May-June 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , pp. 41-48
    • Park, S.1    Jayaraman, S.2
  • 21
    • 14844334233 scopus 로고    scopus 로고
    • E-health and quality of life: The role of the wearable motherboard
    • S. Park and S. Jayaraman, ''e-Health and quality of life: The role of the Wearable Motherboard,'' Stud. Health Technol. Inform., vol.108, pp. 239-252, 2004.
    • (2004) Stud. Health Technol. Inform. , vol.108 , pp. 239-252
    • Park, S.1    Jayaraman, S.2
  • 22
    • 33846914230 scopus 로고    scopus 로고
    • Cable-free body area network using conductive fabric sheets for advanced human-robot interaction
    • E. Wade and H. Asada, ''Cable-free body area network using conductive fabric sheets for advanced human-robot interaction,'' Conf. Proc. IEEE Eng. Med. Biol. Soc., vol.4, pp. 3530-3533, 2005.
    • (2005) Conf. Proc. IEEE Eng. Med. Biol. Soc. , vol.4 , pp. 3530-3533
    • Wade, E.1    Asada, H.2
  • 23
    • 17844369160 scopus 로고    scopus 로고
    • Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation
    • A. Tognetti, F. Lorussi, R. Bartalesi, S. Quaglini, M. Tesconi, G. Zupone, and D. De Rossi, ''Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation,'' J. Neuroeng. Rehab., vol.2, no.8, pp. 1-16, 2005.
    • (2005) J. Neuroeng. Rehab. , vol.2 , Issue.8 , pp. 1-16
    • Tognetti, A.1    Lorussi, F.2    Bartalesi, R.3    Quaglini, S.4    Tesconi, M.5    Zupone, G.6    De Rossi, D.7
  • 27
    • 67849113935 scopus 로고    scopus 로고
    • Design and implementation of a wearable healthcare monitoring system\
    • A. Sagahyroon, H. Raddy, A. Ghazy, and U. Suleman, ''Design and implementation of a wearable healthcare monitoring system,'' Int. J. Electron. Healthc., vol.5, no.1, pp. 68-86, 2009.
    • (2009) Int. J. Electron. Healthc. , vol.5 , Issue.1 , pp. 68-86
    • Sagahyroon, A.1    Raddy, H.2    Ghazy, A.3    Suleman, U.4
  • 28
    • 23944477177 scopus 로고    scopus 로고
    • Personal customizing exercise with a wearable measurement and control unit
    • Z. Wang, T. Kiryu, and N. Tamura, ''Personal customizing exercise with a wearable measurement and control unit,'' J. Neuroeng. Rehabil., vol.2, p. 14, 2005.
    • (2005) J. Neuroeng. Rehabil. , vol.2 , pp. 14
    • Wang, Z.1    Kiryu, T.2    Tamura, N.3
  • 30
    • 38749128695 scopus 로고    scopus 로고
    • MOPET: A context-aware and user-adaptive wearable system for fitness training
    • Feb.
    • F. Buttussi and L. Chittaro, ''MOPET: A context-aware and user-adaptive wearable system for fitness training,'' Artif. Intell. Med., vol.42, pp. 153-163, Feb. 2008.
    • (2008) Artif. Intell. Med. , vol.42 , pp. 153-163
    • Buttussi, F.1    Chittaro, L.2
  • 31
    • 0030821041 scopus 로고    scopus 로고
    • Assessment of posture and motion by multichannel piezoresistive accelerometer recordings
    • Sept.
    • J. Fahrenberg, F. Foerster, M. Smeja, and W. Muller, ''Assessment of posture and motion by multichannel piezoresistive accelerometer recordings,'' Psychophysiology, vol.34, pp. 607-612, Sept. 1997.
    • (1997) Psychophysiology , vol.34 , pp. 607-612
    • Fahrenberg, J.1    Foerster, F.2    Smeja, M.3    Muller, W.4
  • 32
    • 0141833985 scopus 로고    scopus 로고
    • Data mining of motor patterns recorded with wearable technology
    • May-June
    • P. Bonato, P. J. Mork, D. M. Sherrill, and R. H. Westgaard, ''Data mining of motor patterns recorded with wearable technology,'' IEEE Eng. Med. Biol. Mag., vol.22, pp. 110-119, May-June 2003.
    • (2003) IEEE Eng. Med. Biol. Mag. , vol.22 , pp. 110-119
    • Bonato, P.1    Mork, P.J.2    Sherrill, D.M.3    Westgaard, R.H.4
  • 33
    • 0038721184 scopus 로고    scopus 로고
    • Detection of daily physical activities using a triaxial accelerometer
    • May.
    • M. J. Mathie, A. C. Coster, N. H. Lovell, and B. G. Celler, ''Detection of daily physical activities using a triaxial accelerometer,'' Med. Biol. Eng. Comput., vol.41, pp. 296-301, May 2003.
    • (2003) Med. Biol. Eng. Comput. , vol.41 , pp. 296-301
    • Mathie, M.J.1    Coster, A.C.2    Lovell, N.H.3    Celler, B.G.4
  • 34
    • 3142592496 scopus 로고    scopus 로고
    • A pilot study of long-term monitoring of human movements in the home using accelerometry
    • M. J. Mathie, A. C. Coster, N. H. Lovell, B. G. Celler, S. R. Lord, and A. Tiedemann, ''A pilot study of long-term monitoring of human movements in the home using accelerometry,'' J. Telemed. Telecare, vol.10, no.3, pp. 144-151, 2004.
    • (2004) J. Telemed. Telecare , vol.10 , Issue.3 , pp. 144-151
    • Mathie, M.J.1    Coster, A.C.2    Lovell, N.H.3    Celler, B.G.4    Lord, S.R.5    Tiedemann, A.6
  • 36
    • 39449090035 scopus 로고    scopus 로고
    • Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions
    • Jan.
    • M. Ermes, J. Parkka, J. Mantyjarvi, and I. Korhonen, ''Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions,'' IEEE Trans. Inf. Technol. Biomed., vol.12, pp. 20-26, Jan. 2008.
    • (2008) IEEE Trans. Inf. Technol. Biomed. , vol.12 , pp. 20-26
    • Ermes, M.1    Parkka, J.2    Mantyjarvi, J.3    Korhonen, I.4
  • 37
    • 38749116314 scopus 로고    scopus 로고
    • Recognition of dietary activity events using onbody sensors
    • Feb.
    • O. Amft and G. Troster, ''Recognition of dietary activity events using onbody sensors,'' Artif. Intell. Med., vol.42, pp. 121-136, Feb. 2008.
    • (2008) Artif. Intell. Med. , vol.42 , pp. 121-136
    • Amft, O.1    Troster, G.2
  • 38
    • 67650620475 scopus 로고    scopus 로고
    • Bite weight prediction from acoustic recognition of chewing
    • June
    • O. Amft, M. Kusserow, and G. Troster, ''Bite weight prediction from acoustic recognition of chewing,'' IEEE Trans. Biomed. Eng., vol.56, pp. 1663-1672, June 2009.
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , pp. 1663-1672
    • Amft, O.1    Kusserow, M.2    Troster, G.3
  • 41
    • 0033693182 scopus 로고    scopus 로고
    • Detection and assessment of the severity of levodopa-induced dyskinesia in patients with Parkinson's disease by neural networks
    • Nov.
    • N. L. Keijsers, M. W. Horstink, J. J. Van Hilten, J. I. Hoff, and C. C. Gielen, ''Detection and assessment of the severity of levodopa-induced dyskinesia in patients with Parkinson's disease by neural networks,'' Mov. Disord., vol.15, pp. 1104-1111, Nov. 2000.
    • (2000) Mov. Disord. , vol.15 , pp. 1104-1111
    • Keijsers, N.L.1    Horstink, M.W.2    Van Hilten, J.J.3    Hoff, J.I.4    Gielen, C.C.5
  • 42
    • 0037255071 scopus 로고    scopus 로고
    • Automatic assessment of levodopa-induced dyskinesias in daily life by neural networks
    • Jan.
    • N. L. Keijsers, M. W. Horstink, and S. C. Gielen, ''Automatic assessment of levodopa-induced dyskinesias in daily life by neural networks,'' Mov. Disord., vol.18, pp. 70-80, Jan. 2003.
    • (2003) Mov. Disord. , vol.18 , pp. 70-80
    • Keijsers, N.L.1    Horstink, M.W.2    Gielen, S.C.3
  • 43
    • 33244467676 scopus 로고    scopus 로고
    • Ambulatory motor assessment in Parkinson's disease
    • Jan.
    • N. L. Keijsers, M. W. Horstink, and S. C. Gielen, ''Ambulatory motor assessment in Parkinson's disease,'' Mov. Disord., vol.21, pp. 34-44, Jan. 2006.
    • (2006) Mov. Disord. , vol.21 , pp. 34-44
    • Keijsers, N.L.1    Horstink, M.W.2    Gielen, S.C.3
  • 44
    • 46249109734 scopus 로고    scopus 로고
    • An experience of health technology assessment in new models of care for subjects with Parkinson's disease by means of a new wearable device
    • June
    • D. Giansanti, G. Maccioni, and S. Morelli, ''An experience of health technology assessment in new models of care for subjects with Parkinson's disease by means of a new wearable device,'' Telemed. J. E. Health, vol.14, pp. 467-472, June 2008.
    • (2008) Telemed. J. E. Health , vol.14 , pp. 467-472
    • Giansanti, D.1    MacCioni, G.2    Morelli, S.3
  • 47
    • 0000224448 scopus 로고
    • Recent Developments in Parkinson's Disease, S. Fahn, Ed. New York, NY: MacMillan Healthcare Information
    • S. Fahn and R. L. Elton, ''Unified Parkinson's Disease Rating Scale,'' Recent Developments in Parkinson's Disease, S. Fahn, Ed. New York, NY: MacMillan Healthcare Information, 1987, pp. 153-163.
    • (1987) Unified Parkinson's Disease Rating Scale , pp. 153-163
    • Fahn, S.1    Elton, R.L.2
  • 49
    • 34547818589 scopus 로고    scopus 로고
    • Design of wearable cardiac telemedicine system
    • V. Thulasi Bai and S. K. Srivatsa, ''Design of wearable cardiac telemedicine system,'' Int. J. Electron. Healthc., vol.3, no.3, pp. 303-316, 2007.
    • (2007) Int. J. Electron. Healthc. , vol.3 , Issue.3 , pp. 303-316
    • Thulasi Bai, V.1    Srivatsa, S.K.2
  • 52
    • 70349571602 scopus 로고    scopus 로고
    • Advances in wearable technology for rehabilitation
    • P. Bonato, ''Advances in wearable technology for rehabilitation,'' Stud. Health Technol. Inform., vol.145, pp. 145-159, 2009.
    • (2009) Stud. Health Technol. Inform. , vol.145 , pp. 145-159
    • Bonato, P.1
  • 53
    • 60549105219 scopus 로고    scopus 로고
    • Effects of training with a robot-virtual reality system compared with a robot alone on the gait of individuals after stroke
    • Jan.
    • A. Mirelman, P. Bonato, and J. E. Deutsch, ''Effects of training with a robot-virtual reality system compared with a robot alone on the gait of individuals after stroke,'' Stroke, vol.40, pp. 169-174, Jan. 2009.
    • (2009) Stroke , vol.40 , pp. 169-174
    • Mirelman, A.1    Bonato, P.2    Deutsch, J.E.3
  • 54
    • 23944462224 scopus 로고    scopus 로고
    • Gait variability: Methods, modeling and meaning
    • J. M. Hausdorff, ''Gait variability: Methods, modeling and meaning,'' J. Neuroeng. Rehabil., vol.2, p. 19, 2005.
    • (2005) J. Neuroeng. Rehabil. , vol.2 , pp. 19
    • Hausdorff, J.M.1
  • 55
    • 34548216348 scopus 로고    scopus 로고
    • Gait dynamics, fractals and falls: Finding meaning in the stride-to-stride fluctuations of human walking
    • Aug.
    • J. M. Hausdorff, ''Gait dynamics, fractals and falls: Finding meaning in the stride-to-stride fluctuations of human walking,'' Hum. Mov. Sci., vol.26, pp. 555- 589, Aug. 2007.
    • (2007) Hum. Mov. Sci. , vol.26 , pp. 555-589
    • Hausdorff, J.M.1
  • 56
    • 34249934082 scopus 로고    scopus 로고
    • Evaluation of a thresholdbased tri-axial accelerometer fall detection algorithm
    • July
    • A. K. Bourke, J. V. O'brien, and G. M. Lyons, ''Evaluation of a thresholdbased tri-axial accelerometer fall detection algorithm,'' Gait Posture, vol.26, pp. 194-199, July 2007.
    • (2007) Gait Posture , vol.26 , pp. 194-199
    • Bourke, A.K.1    O'Brien, J.V.2    Lyons, G.M.3
  • 57
    • 38149045656 scopus 로고    scopus 로고
    • A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor
    • Jan.
    • A. K. Bourke and G. M. Lyons, ''A threshold-based fall-detection algorithm using a bi-axial gyroscope sensor,'' Med. Eng. Phys., vol.30, pp. 84-90, Jan. 2008.
    • (2008) Med. Eng. Phys. , vol.30 , pp. 84-90
    • Bourke, A.K.1    Lyons, G.M.2
  • 58
    • 42049095315 scopus 로고    scopus 로고
    • Portable preimpact fall detector with inertial sensors
    • Apr.
    • G. Wu and S. Xue, ''Portable preimpact fall detector with inertial sensors,'' IEEE Trans. Neural Syst. Rehabil. Eng., vol.16, pp. 178-183, Apr. 2008.
    • (2008) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.16 , pp. 178-183
    • Wu, G.1    Xue, S.2
  • 59
    • 40149103814 scopus 로고    scopus 로고
    • Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography
    • DOI 10.1016/j.medengphy.2007.04.006, PII S1350453307000653
    • D. Giansanti, G. Maccioni, S. Cesinaro, F. Benvenuti, and V. Macellari, ''Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography,'' Med. Eng. Phys., vol.30, pp. 367-372, Apr. 2008. (Pubitemid 351324875)
    • (2008) Medical Engineering and Physics , vol.30 , Issue.3 , pp. 367-372
    • Giansanti, D.1    Maccioni, G.2    Cesinaro, S.3    Benvenuti, F.4    Macellari, V.5
  • 61
    • 77950196333 scopus 로고    scopus 로고
    • Unobtrusive and ubiquitous in-home monitoring: A methodology for continuous assessment of gait velocity in elders
    • to be published
    • S. Hagler, D. Austin, T. Hayes, J. Kaye, and M. Pavel, ''Unobtrusive and ubiquitous in-home monitoring: A methodology for continuous assessment of gait velocity in elders,'' IEEE Trans. Biomed. Eng., to be published.
    • IEEE Trans. Biomed. Eng.
    • Hagler, S.1    Austin, D.2    Hayes, T.3    Kaye, J.4    Pavel, M.5
  • 62
    • 55549132656 scopus 로고    scopus 로고
    • Unobtrusive assessment of activity patterns associated with mild cognitive impairment
    • Nov.
    • T. L. Hayes, F. Abendroth, A. Adami, M. Pavel, T. A. Zitzelberger, and J. A. Kaye, ''Unobtrusive assessment of activity patterns associated with mild cognitive impairment,'' Alzheimers Dement., vol.4, pp. 395-405, Nov. 2008.
    • (2008) Alzheimers Dement. , vol.4 , pp. 395-405
    • Hayes, T.L.1    Abendroth, F.2    Adami, A.3    Pavel, M.4    Zitzelberger, T.A.5    Kaye, J.A.6
  • 65
    • 70349241778 scopus 로고    scopus 로고
    • Role of wearable and automatic external defibrillators in improving survival in patients at risk for sudden cardiac death
    • Oct.
    • B. K. Lee and J. E. Olgin, ''Role of wearable and automatic external defibrillators in improving survival in patients at risk for sudden cardiac death,'' Curr. Treat. Options Cardiovasc. Med., vol.11, pp. 360-365, Oct. 2009.
    • (2009) Curr. Treat. Options Cardiovasc. Med. , vol.11 , pp. 360-365
    • Lee, B.K.1    Olgin, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.