메뉴 건너뛰기




Volumn 34, Issue 5, 2010, Pages 442-446

Estimation of maximum ventricular elastance under assistance with a rotary blood pump

Author keywords

Elastance; Estimation techniques; Heart contractility; Myocardial recovery; Ventricular assist device; Ventricular function

Indexed keywords

BLOOD; PUMPS; RECOVERY;

EID: 77952235189     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00876.x     Document Type: Article
Times cited : (5)

References (11)
  • 2
    • 0016280920 scopus 로고
    • Instantaneous pressure-volume relationships and their ratio in the excised supported canine left
    • Suga H, Sagawa K. Instantaneous pressure-volume relationships and their ratio in the excised supported canine left. Circ Res 1974 35 : 117.
    • (1974) Circ Res , vol.35 , pp. 117
    • Suga, H.1    Sagawa, K.2
  • 3
    • 23744500968 scopus 로고    scopus 로고
    • Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: A guide for clinical, translational and basic researchers
    • Burkhoff D, Mirsky I, Suga H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational and basic researchers. Am J Physiol Heart 2005 289 : 501 512.
    • (2005) Am J Physiol Heart , vol.289 , pp. 501-512
    • Burkhoff, D.1    Mirsky, I.2    Suga, H.3
  • 4
    • 34047190829 scopus 로고    scopus 로고
    • Evaluation of cardiac function based on ventricular pressure-volume relationships during assistance with a rotary blood pump
    • Ogawa D, Tanaka A, Abe K, et al. Evaluation of cardiac function based on ventricular pressure-volume relationships during assistance with a rotary blood pump. Conf Proc IEEE Eng Med Biol Soc 2006 28 : 5378 5381.
    • (2006) Conf Proc IEEE Eng Med Biol Soc , vol.28 , pp. 5378-5381
    • Ogawa, D.1    Tanaka, A.2    Abe, K.3
  • 5
    • 12244280887 scopus 로고    scopus 로고
    • An approach to single-beat estimation of Emax as an inverse problem
    • Yoshizawa M, Tanaka A, Abe K, et al. An approach to single-beat estimation of Emax as an inverse problem. Conf Proc IEEE Eng Med Biol Soc 1998 20 : 379 382.
    • (1998) Conf Proc IEEE Eng Med Biol Soc , vol.20 , pp. 379-382
    • Yoshizawa, M.1    Tanaka, A.2    Abe, K.3
  • 6
    • 26244457597 scopus 로고    scopus 로고
    • Myocardial contractility in the echo lab: Molecular, cellular and pathophysiological basis
    • Bombardini T. Myocardial contractility in the echo lab: molecular, cellular and pathophysiological basis. Cardiovasc Ultrasound 2005 3 : 27.
    • (2005) Cardiovasc Ultrasound , vol.3 , pp. 27
    • Bombardini, T.1
  • 7
    • 33645743807 scopus 로고    scopus 로고
    • Modeling ventricular function during cardiac assist: Does time-varying elastance work?
    • Vandenberghe S, Segers P, Steendijk P, et al. Modeling ventricular function during cardiac assist: does time-varying elastance work? ASAIO J 2006 52 : 4 8.
    • (2006) ASAIO J , vol.52 , pp. 4-8
    • Vandenberghe, S.1    Segers, P.2    Steendijk, P.3
  • 8
    • 0036084425 scopus 로고    scopus 로고
    • Pressure-volume-based single-beat estimations cannot predict left ventricular contractility in vivo
    • Kjorstad KE, Korvald C, Myrmel T. Pressure-volume-based single-beat estimations cannot predict left ventricular contractility in vivo. Am J Physiol Heart Circ Physiol 2002 282 : H1739 50.
    • (2002) Am J Physiol Heart Circ Physiol , vol.282 , pp. 1739-1750
    • Kjorstad, K.E.1    Korvald, C.2    Myrmel, T.3
  • 9
    • 0025967154 scopus 로고
    • Single beat estimation of the slope of the end-systolic pressure-volume relation in the human left ventricle
    • Takeuchi M, Igarashi Y, Tomimoto S, Odake M, Hayashi T, Tsukamoto T. Single beat estimation of the slope of the end-systolic pressure-volume relation in the human left ventricle. Circulation 1991 83 : 202 212.
    • (1991) Circulation , vol.83 , pp. 202-212
    • Takeuchi, M.1    Igarashi, Y.2    Tomimoto, S.3    Odake, M.4    Hayashi, T.5    Tsukamoto, T.6
  • 10
    • 0029803624 scopus 로고
    • Single-beat estimation of end-systolic pressure-volume relation in humans. A new method with the potential for noninvasive application
    • Senzaki H, Chen CH, Kass DA. Single-beat estimation of end-systolic pressure-volume relation in humans. A new method with the potential for noninvasive application. Circulation 1991 94 : 2497 2506.
    • (1991) Circulation , vol.94 , pp. 2497-2506
    • Senzaki, H.1    Chen, C.H.2    Kass, D.A.3
  • 11
    • 0034680308 scopus 로고    scopus 로고
    • Single-beat estimation of end-systolic elastance using bilinearly approximated time-varying elastance
    • Shishido T, Hayashi K, Shigemi K, Sato T, Sugimachi M, Sunagawa K. Single-beat estimation of end-systolic elastance using bilinearly approximated time-varying elastance. Circulation 2000 102 : 1983 1989.
    • (2000) Circulation , vol.102 , pp. 1983-1989
    • Shishido, T.1    Hayashi, K.2    Shigemi, K.3    Sato, T.4    Sugimachi, M.5    Sunagawa, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.