메뉴 건너뛰기




Volumn , Issue , 2010, Pages 2126-2131

Active damping for torsional vibrations in PMSG based WECS

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE DAMPING; CONSTANT POWER; CONTROL STRATEGIES; DAMPING TORQUES; DC LINK VOLTAGE CONTROL; DC VOLTAGE CONTROL; DIRECT-DRIVEN; DRIVE TRAIN; INTERNAL DAMPING; MAXIMUM POWER; OUTPUT POWER; PERMANENT MAGNETICS; POWER REGULATION; POWER SIGNALS; SIMULATION RESULT; TORSIONAL VIBRATION; WIND ENERGY CONVERSION SYSTEM;

EID: 77952214713     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/APEC.2010.5433530     Document Type: Conference Paper
Times cited : (9)

References (14)
  • 3
    • 55349113607 scopus 로고    scopus 로고
    • Modelling and control of variable-speed multi-pole permanent magnet synchronous generator wind turbine
    • Anca D. Hansen, Gabriele Michalke, "Modelling and control of variable-speed multi-pole permanent magnet synchronous generator wind turbine", Wind Energy, 2008, 11(5), pp. 537-554.
    • (2008) Wind Energy , vol.11 , Issue.5 , pp. 537-554
    • Hansen, A.D.1    Michalke, G.2
  • 7
    • 0036630441 scopus 로고    scopus 로고
    • Analysis of a power oscillation damping scheme using a voltage-source inverter
    • Rigby, B.S., Chonco, N.S., Harley, R.G., "Analysis of a power oscillation damping scheme using a voltage-source inverter", IEEE Transactions on Industry Applications, 38(4), 2002, pp.1105-1113.
    • (2002) IEEE Transactions on Industry Applications , vol.38 , Issue.4 , pp. 1105-1113
    • Rigby, B.S.1    Chonco, N.S.2    Harley, R.G.3
  • 8
    • 34249780371 scopus 로고    scopus 로고
    • Control methodology to mitigate the grid impact of wind turbines
    • DOI 10.1109/TEC.2006.878242
    • Rawn, B.G., Lehn, P.W., Maggiore, M., "Control Methodology to Mitigate the Grid Impact of Wind Turbines", IEEE Transaction on Energy Conversion, 2007, 22(2): 431-438. (Pubitemid 46845643)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 431-438
    • Rawn, B.G.1    Lehn, P.W.2    Maggiore, M.3
  • 9
    • 60449099257 scopus 로고    scopus 로고
    • Control of the reactive power supplied by a wecs based on an induction generator fed by a matrix converter
    • Feb.
    • R. Cardenas, R. Pena, P. Wheeler, J. Clare, and G. Asher, "Control of the reactive power supplied by a wecs based on an induction generator fed by a matrix converter," Industrial Electronics, IEEE Transactions on, vol. 56, no. 2, pp. 429-438, Feb. 2009.
    • (2009) Industrial Electronics, IEEE Transactions on , vol.56 , Issue.2 , pp. 429-438
    • Cardenas, R.1    Pena, R.2    Wheeler, P.3    Clare, J.4    Asher, G.5
  • 10
    • 0032593021 scopus 로고    scopus 로고
    • Performance optimization for doubly fed wind power generation systems
    • Jul/Aug
    • S. Bhowmik, R. Spee, and J. Enslin, "Performance optimization for doubly fed wind power generation systems," Industry Applications, IEEE Transactions on, vol. 35, no. 4, pp. 949-958, Jul/Aug 1999.
    • (1999) Industry Applications, IEEE Transactions on , vol.35 , Issue.4 , pp. 949-958
    • Bhowmik, S.1    Spee, R.2    Enslin, J.3
  • 11
    • 69449085926 scopus 로고    scopus 로고
    • A review of the state of the art of power electronics for wind turbines
    • Aug.
    • Z. Chen, J. M. Guerrero, and F. Blaabjerg, "A review of the state of the art of power electronics for wind turbines," Power Electronics, IEEE Transactions on, vol. 24, no. 8, pp. 1859-1875, Aug. 2009.
    • (2009) Power Electronics, IEEE Transactions on , vol.24 , Issue.8 , pp. 1859-1875
    • Chen, Z.1    Guerrero, J.M.2    Blaabjerg, F.3
  • 12
    • 2942569637 scopus 로고    scopus 로고
    • Optimum control strategies in energy conversion of pmsg wind turbine system without mechanical sensors
    • June
    • K. Tan and S. Islam, "Optimum control strategies in energy conversion of pmsg wind turbine system without mechanical sensors," Energy Conversion, IEEE Transactions on, vol. 19, no. 2, pp. 392-399, June 2004.
    • (2004) Energy Conversion, IEEE Transactions on , vol.19 , Issue.2 , pp. 392-399
    • Tan, K.1    Islam, S.2
  • 13
    • 20444427743 scopus 로고    scopus 로고
    • E.ON Netz. GmbH Bayreuth, August
    • E.ON Netz GmbH "Grid Code High and Extra High Voltage", E.ON Netz. GmbH Bayreuth, August 2003, http://www.eon-netz.com.
    • (2003) Grid Code High and Extra High Voltage