메뉴 건너뛰기




Volumn 8, Issue 5, 2010, Pages 613-615

Editorial: Stent design matters: Insights from virtual bench testing

Author keywords

[No Author keywords available]

Indexed keywords

BARE METAL STENT; COMPUTATIONAL FLUID DYNAMICS; COMPUTER MODEL; DRUG ELUTING STENT; EDITORIAL; EVENT FREE SURVIVAL; FINITE ELEMENT ANALYSIS; FOLLOW UP; QUALITY CONTROL; RESTENOSIS; STENT; VIRTUAL BENCH TEST; VIRTUAL REALITY; COMPUTER AIDED DESIGN; COMPUTER SIMULATION; HUMAN; PROSTHESIS;

EID: 77952125523     PISSN: 14779072     EISSN: 17448344     Source Type: Journal    
DOI: 10.1586/erc.10.32     Document Type: Editorial
Times cited : (3)

References (9)
  • 1
    • 0033933524 scopus 로고    scopus 로고
    • Influence of stent design on 1-year outcome after coronary stent placement: A randomized comparison of five stent types in 1147 unselected patients
    • Kastrati A, Dirschinger J, Boekstegers P et al. Influence of stent design on 1-year outcome after coronary stent placement: a randomized comparison of five stent types in 1147 unselected patients. Cathet. Cardiovasc. Intervent. 50(3), 290-297 (2000).
    • (2000) Cathet. Cardiovasc. Intervent. , vol.50 , Issue.3 , pp. 290-297
    • Kastrati, A.1    Dirschinger, J.2    Boekstegers, P.3
  • 2
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trial
    • Kastrati A, Mehilli J, Dirschinger J et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103(23), 2816-2821 (2001).
    • (2001) Circulation , vol.103 , Issue.23 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 3
    • 61549097471 scopus 로고    scopus 로고
    • Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: Two-year clinical follow-up from the clinical evaluation of the Xience v everolimus-eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions (SPIRIT) III trial
    • Stone GW, Midei M, Newman W et al. Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the clinical evaluation of the Xience V everolimus-eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions (SPIRIT) III trial. Circulation 119(5), 680-686 (2009).
    • (2009) Circulation , vol.119 , Issue.5 , pp. 680-686
    • Stone, G.W.1    Midei, M.2    Newman, W.3
  • 4
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C, Edelman ER. Endovascular stent design dictates experimental restenosis and thrombosis. Circulation 91(12), 2995-3001 (1995).
    • (1995) Circulation , vol.91 , Issue.12 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2
  • 5
    • 0035985022 scopus 로고    scopus 로고
    • The role of computational fluid dynamics for artificial organ design
    • Verdonck P. The role of computational fluid dynamics for artificial organ design. Artif. Organs 26(7), 569-570 (2002).
    • (2002) Artif. Organs , vol.26 , Issue.7 , pp. 569-570
    • Verdonck, P.1
  • 6
    • 74249102209 scopus 로고    scopus 로고
    • A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: Comparison of three drug-eluting stents
    • Mortier P, Holzapfel GA, De Beule M et al. A novel simulation strategy for stent insertion and deployment in curved coronary bifurcations: comparison of three drug-eluting stents. Ann. Biomed. Eng. 38(1), 88-99 (2010).
    • (2010) Ann. Biomed. Eng. , vol.38 , Issue.1 , pp. 88-99
    • Mortier, P.1    Holzapfel, G.A.2    De Beule, M.3
  • 7
    • 70350026670 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation
    • Liu X, Tsujita K, Maehara A et al. Intravascular ultrasound assessment of the incidence and predictors of edge dissections after drug-eluting stent implantation. JACC Cardiovasc. Interv. 2(10), 997-1004 (2009).
    • (2009) JACC Cardiovasc. Interv. , vol.2 , Issue.10 , pp. 997-1004
    • Liu, X.1    Tsujita, K.2    Maehara, A.3
  • 8
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N. Engl. J. Med. 349(14), 1315-1323 (2003).
    • (2003) N. Engl. J. Med. , vol.349 , Issue.14 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 9
    • 0034254951 scopus 로고    scopus 로고
    • True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation
    • Slager CJ, Wentzel JJ, Schuurbiers JC et al. True 3-dimensional reconstruction of coronary arteries in patients by fusion of angiography and IVUS (ANGUS) and its quantitative validation. Circulation 102(5), 511-516 (2000).
    • (2000) Circulation , vol.102 , Issue.5 , pp. 511-516
    • Slager, C.J.1    Wentzel, J.J.2    Schuurbiers, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.