Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; BIOMECHANICS; BONE PLATE; BONE SCREW; CADAVER; COMPRESSION; CONTROLLED STUDY; FIXATION DEVICE; HUMAN; HUMAN TISSUE; HUMERUS HEAD; MECHANICAL TORSION; OSTEOTOMY; PLATE FIXATION; PRIORITY JOURNAL; COMPARATIVE STUDY; COMPRESSIVE STRENGTH; DEVICES; HUMERUS; MATERIALS TESTING; OSTEOSYNTHESIS; PATHOPHYSIOLOGY; PROSTHESIS; REPRODUCIBILITY; SHOULDER FRACTURES; STANDARDS;

EID: 77952101341     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2009.11.003     Document Type: Article
Times cited : (37)

References (28)
  • 1
    • 43949112618 scopus 로고    scopus 로고
    • Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures
    • Badman B.L., and Mighell M. Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures. J Am Acad Orthop Surg 16 (2008) 294-302
    • (2008) J Am Acad Orthop Surg , vol.16 , pp. 294-302
    • Badman, B.L.1    Mighell, M.2
  • 2
    • 0348110615 scopus 로고    scopus 로고
    • Fixed-angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device
    • Chudik S.C., Weinhold P., and Dahners L.E. Fixed-angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device. J Shoulder Elbow Surg 12 (2003) 578-588
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 578-588
    • Chudik, S.C.1    Weinhold, P.2    Dahners, L.E.3
  • 3
    • 33745994558 scopus 로고    scopus 로고
    • Epidemiology of adult fractures: a review
    • Court-Brown C.M., and Caesar B. Epidemiology of adult fractures: a review. Injury 37 (2006) 691-697
    • (2006) Injury , vol.37 , pp. 691-697
    • Court-Brown, C.M.1    Caesar, B.2
  • 4
    • 0034866296 scopus 로고    scopus 로고
    • The translated two-part fracture of the proximal humerus. Epidemiology and outcome in the older patient
    • Court-Brown C.M., Garg A., and McQueen M.M. The translated two-part fracture of the proximal humerus. Epidemiology and outcome in the older patient. J Bone Joint Surg Br 83 (2001) 799-804
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 799-804
    • Court-Brown, C.M.1    Garg, A.2    McQueen, M.M.3
  • 6
    • 36549017108 scopus 로고    scopus 로고
    • Two-part fractures and fracture dislocations
    • 397,414, v
    • Court-Brown C.M., and McQueen M.M. Two-part fractures and fracture dislocations. Hand Clin 23 (2007) 397,414, v
    • (2007) Hand Clin , vol.23
    • Court-Brown, C.M.1    McQueen, M.M.2
  • 7
    • 33749562322 scopus 로고    scopus 로고
    • Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques
    • Edwards S.L., Wilson N.A., Zhang L.Q., Flores S., and Merk B.R. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. J Bone Joint Surg Am 88 (2006) 2258-2264
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 2258-2264
    • Edwards, S.L.1    Wilson, N.A.2    Zhang, L.Q.3    Flores, S.4    Merk, B.R.5
  • 8
    • 0041318956 scopus 로고    scopus 로고
    • Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3)
    • Fankhauser F., Schippinger G., Weber K., Heinz S., Quehenberger F., Boldin C., et al. Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3). J Trauma 55 (2003) 345-349
    • (2003) J Trauma , vol.55 , pp. 345-349
    • Fankhauser, F.1    Schippinger, G.2    Weber, K.3    Heinz, S.4    Quehenberger, F.5    Boldin, C.6
  • 9
    • 33750230959 scopus 로고    scopus 로고
    • A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures
    • Fuchtmeier B., May R., Fierlbeck J., Hammer J., and Nerlich M. A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures. Technol Health Care 14 (2006) 261-270
    • (2006) Technol Health Care , vol.14 , pp. 261-270
    • Fuchtmeier, B.1    May, R.2    Fierlbeck, J.3    Hammer, J.4    Nerlich, M.5
  • 10
    • 34547115714 scopus 로고    scopus 로고
    • Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants
    • Fuchtmeier B., May R., Hente R., Maghsudi M., Volk M., Hammer J., et al. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants. Arch Orthop Trauma Surg 127 (2007) 441-447
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 441-447
    • Fuchtmeier, B.1    May, R.2    Hente, R.3    Maghsudi, M.4    Volk, M.5    Hammer, J.6
  • 11
    • 0035323997 scopus 로고    scopus 로고
    • Cyclic loading of rotator cuff repairs: A comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures
    • Goradia V.K., Mullen D.J., Boucher H.R., Parks B.G., and O'Donnell J.B. Cyclic loading of rotator cuff repairs: A comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. Arthroscopy 17 (2001) 360-364
    • (2001) Arthroscopy , vol.17 , pp. 360-364
    • Goradia, V.K.1    Mullen, D.J.2    Boucher, H.R.3    Parks, B.G.4    O'Donnell, J.B.5
  • 12
    • 30144438757 scopus 로고    scopus 로고
    • A comparison of shoulder joint forces during ambulation with crutches versus a walker in persons with incomplete spinal cord injury
    • Haubert L.L., Gutierrez D.D., Newsam C.J., Gronley J.K., Mulroy S.J., and Perry J. A comparison of shoulder joint forces during ambulation with crutches versus a walker in persons with incomplete spinal cord injury. Arch Phys Med Rehabil 87 (2006) 63-70
    • (2006) Arch Phys Med Rehabil , vol.87 , pp. 63-70
    • Haubert, L.L.1    Gutierrez, D.D.2    Newsam, C.J.3    Gronley, J.K.4    Mulroy, S.J.5    Perry, J.6
  • 13
    • 33645046408 scopus 로고    scopus 로고
    • New trends in the treatment of proximal humerus fractures
    • Helmy N., and Hintermann B. New trends in the treatment of proximal humerus fractures. Clin Orthop Relat Res 442 (2006) 100-108
    • (2006) Clin Orthop Relat Res , vol.442 , pp. 100-108
    • Helmy, N.1    Hintermann, B.2
  • 14
    • 22544468510 scopus 로고    scopus 로고
    • Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation
    • Hessmann M.H., Hansen W.S., Krummenauer F., Pol T.F., and Rommens P.M. Locked plate fixation and intramedullary nailing for proximal humerus fractures: a biomechanical evaluation. J Trauma 58 (2005) 1194-1201
    • (2005) J Trauma , vol.58 , pp. 1194-1201
    • Hessmann, M.H.1    Hansen, W.S.2    Krummenauer, F.3    Pol, T.F.4    Rommens, P.M.5
  • 15
    • 0030004494 scopus 로고    scopus 로고
    • Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques
    • Koval K.J., Blair B., Takei R., Kummer F.J., and Zuckerman J.D. Surgical neck fractures of the proximal humerus: a laboratory evaluation of ten fixation techniques. J Trauma 40 (1996) 778-783
    • (1996) J Trauma , vol.40 , pp. 778-783
    • Koval, K.J.1    Blair, B.2    Takei, R.3    Kummer, F.J.4    Zuckerman, J.D.5
  • 16
    • 0031659587 scopus 로고    scopus 로고
    • A model predicting individual shoulder muscle forces based on relationship between electromyographic and 3D external forces in static position
    • Laursen B., Jensen B.R., Nemeth G., and Sjogaard G. A model predicting individual shoulder muscle forces based on relationship between electromyographic and 3D external forces in static position. J Biomech 31 (1998) 731-739
    • (1998) J Biomech , vol.31 , pp. 731-739
    • Laursen, B.1    Jensen, B.R.2    Nemeth, G.3    Sjogaard, G.4
  • 17
    • 0024384196 scopus 로고
    • The epidemiology of fractures of the proximal humerus
    • Lind T., Kroner K., and Jensen J. The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg 108 (1989) 285-287
    • (1989) Arch Orthop Trauma Surg , vol.108 , pp. 285-287
    • Lind, T.1    Kroner, K.2    Jensen, J.3
  • 18
    • 47849084486 scopus 로고    scopus 로고
    • Volar plating of AO C3 distal radius fractures: biomechanical evaluation of locking screw and locking smooth peg configurations
    • Martineau P.A., Waitayawinyu T., and Malone K.J. Volar plating of AO C3 distal radius fractures: biomechanical evaluation of locking screw and locking smooth peg configurations. J Hand Surg [Am] 33 (2008) 827-834
    • (2008) J Hand Surg [Am] , vol.33 , pp. 827-834
    • Martineau, P.A.1    Waitayawinyu, T.2    Malone, K.J.3
  • 19
    • 3242668713 scopus 로고    scopus 로고
    • A study of the external forces and moments at the shoulder and elbow while performing every day tasks
    • Murray I.A., and Johnson G.R. A study of the external forces and moments at the shoulder and elbow while performing every day tasks. Clin Biomech (Bristol, Avon) 19 (2004) 586-594
    • (2004) Clin Biomech (Bristol, Avon) , vol.19 , pp. 586-594
    • Murray, I.A.1    Johnson, G.R.2
  • 20
    • 0018084946 scopus 로고
    • Forces at the glenohumeral joint in abduction
    • Poppen N.K., and Walker P.S. Forces at the glenohumeral joint in abduction. Clin Orthop Relat Res (1978) 165-170
    • (1978) Clin Orthop Relat Res , pp. 165-170
    • Poppen, N.K.1    Walker, P.S.2
  • 21
    • 0034028580 scopus 로고    scopus 로고
    • Predicting mechanical load of the glenohumeral joint, using net joint moments
    • Praagman M., Stokdijk M., Veeger H.E., and Visser B. Predicting mechanical load of the glenohumeral joint, using net joint moments. Clin Biomech (Bristol, Avon) 15 (2000) 315-321
    • (2000) Clin Biomech (Bristol, Avon) , vol.15 , pp. 315-321
    • Praagman, M.1    Stokdijk, M.2    Veeger, H.E.3    Visser, B.4
  • 22
    • 0033629482 scopus 로고    scopus 로고
    • Fixation of three-part proximal humeral fractures: a biomechanical evaluation
    • Ruch D.S., Glisson R.R., Marr A.W., Russell G.B., and Nunley J.A. Fixation of three-part proximal humeral fractures: a biomechanical evaluation. J Orthop Trauma 14 (2000) 36-40
    • (2000) J Orthop Trauma , vol.14 , pp. 36-40
    • Ruch, D.S.1    Glisson, R.R.2    Marr, A.W.3    Russell, G.B.4    Nunley, J.A.5
  • 25
    • 33748957058 scopus 로고    scopus 로고
    • Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri
    • Siffri P.C., Peindl R.D., Coley E.R., Norton J., Connor P.M., and Kellam J.F. Biomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri. J Orthop Trauma 20 (2006) 547-554
    • (2006) J Orthop Trauma , vol.20 , pp. 547-554
    • Siffri, P.C.1    Peindl, R.D.2    Coley, E.R.3    Norton, J.4    Connor, P.M.5    Kellam, J.F.6
  • 26
    • 0033821667 scopus 로고    scopus 로고
    • Effect of immediate weightbearing on plated fractures of the humeral shaft
    • Tingstad E.M., Wolinsky P.R., Shyr Y., and Johnson K.D. Effect of immediate weightbearing on plated fractures of the humeral shaft. J Trauma 49 (2000) 278-280
    • (2000) J Trauma , vol.49 , pp. 278-280
    • Tingstad, E.M.1    Wolinsky, P.R.2    Shyr, Y.3    Johnson, K.D.4
  • 28
    • 33750632703 scopus 로고    scopus 로고
    • Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model
    • Walsh S., Reindl R., Harvey E., Berry G., Beckman L., and Steffen T. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Clin Biomech (Bristol, Avon) 21 (2006) 1027-1031
    • (2006) Clin Biomech (Bristol, Avon) , vol.21 , pp. 1027-1031
    • Walsh, S.1    Reindl, R.2    Harvey, E.3    Berry, G.4    Beckman, L.5    Steffen, T.6