4
-
-
27144487426
-
Transfer function analysis using STFT for improvement of the fault detection sensitivity in transformer impulse test
-
Al-Ammar E, Karady GG. Transfer function analysis using STFT for improvement of the fault detection sensitivity in transformer impulse test. In Proceedings of the IEEE Power Engineering Society General Meeting, 2005; 534-541.
-
(2005)
Proceedings of the IEEE Power Engineering Society General Meeting
, pp. 534-541
-
-
Al-Ammar, E.1
Karady, G.G.2
-
6
-
-
42249100477
-
A new technique to detect winding displacements in power transformers using frequency response analysis
-
Bologna, 1, 2 June
-
Coffeen L, Britton J, Rickmann J. A new technique to detect winding displacements in power transformers using frequency response analysis. In Proceedings of IEEE PowerTech, Bologna, 1, 2 June 2003.
-
(2003)
Proceedings of IEEE PowerTech
-
-
Coffeen, L.1
Britton, J.2
Rickmann, J.3
-
7
-
-
0023985044
-
Impulse testing of power transformers using transfer function method
-
Malewski R, Poulin B. Impulse testing of power transformers using transfer function method. IEEE Transactions on Power Delivery 1998; 2(3):476-489.
-
(1998)
IEEE Transactions on Power Delivery
, vol.2
, Issue.3
, pp. 476-489
-
-
Malewski, R.1
Poulin, B.2
-
8
-
-
42549153602
-
Frequency response analysis (FRA) for transformer testing using FRAMIT: Its application and interpretation
-
North America
-
Breytenbach R. Frequency response analysis (FRA) for transformer testing using FRAMIT: its application and interpretation. In Proceeding of TechCon, 2000; North America.
-
(2000)
Proceeding of TechCon
-
-
Breytenbach, R.1
-
9
-
-
42549119749
-
Frequency response analysis of power transformers: Practical aspects of FRA testing and interpretation
-
New Orleans LA March
-
Britton JA, Dowiak M. Frequency response analysis of power transformers: practical aspects of FRA testing and interpretation. In Proceedings of NETA Annual Technical Conference, New Orleans, LA, March 2005.
-
(2005)
Proceedings of NETA Annual Technical Conference
-
-
Britton, J.A.1
Dowiak, M.2
-
10
-
-
0015622099
-
Bonneville power administration transformer short circuit test results; comparison of winding inspection with diagnostic methods
-
Gillies DA, Humbard LE, Rogers EJ. Bonneville Power Administration transformer short circuit test results; comparison of winding inspection with diagnostic methods. IEEE Transactions on Power Apparatus and Systems 1973; 3(92):934-942.
-
(1973)
IEEE Transactions on Power Apparatus and Systems
, vol.3
, Issue.92
, pp. 934-942
-
-
Gillies, D.A.1
Humbard, L.E.2
Rogers, E.J.3
-
15
-
-
17744399301
-
Frequency Response Analysis approach for condition monitoring of transformer
-
3A-6, 2004 Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
-
Nirgude PM, Gunasekaran B, Channakeshava, R, Rajkumar AD, Singh BP. Frequency response analysis approach for condition monitoring of transformer. In Proceedings of the IEEE on Electrical Insulation and Dielectric Phenomena, 2004; 186-189. (Pubitemid 40574770)
-
(2004)
Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
, pp. 186-189
-
-
Nirgude, P.M.1
Gunasekaran, B.2
Channakeshava3
Rajkumar, A.D.4
Singh, B.P.5
-
17
-
-
84939815463
-
Transformer maintenance and diagnostics using frequency response analysis
-
February Available at
-
Britton JA. Transformer maintenance and diagnostics using frequency response analysis, Article Presented at Electric Energy T&D Magazine, February 2004. Available at: http://electricenergyonline.com/article.asp?m= 5&mag=19&article=145
-
(2004)
Article Presented at Electric Energy T&D Magazine
-
-
Britton, J.A.1
-
18
-
-
42549168953
-
Improved technique for fault detection sensitivity in transformer maintenance test
-
DOI 10.1109/PES.2007.385614, 2007 IEEE Power Engineering Society General Meeting, PES
-
Al-Ammar E, Karady GG, Hevia OP. Improved technique for fault detection sensitivity in transformer maintenance test. In Proceedings of the IEEE Power Engineering Society General Meeting, June 2007. (Pubitemid 351580269)
-
(2007)
2007 IEEE Power Engineering Society General Meeting, PES
, pp. 4275223
-
-
Al-Ammar, E.1
Karady, G.G.2
Hevia, O.P.3
-
19
-
-
0026372656
-
Effect of charge, feed, and test cable lengths on R2SPG waveforms
-
August
-
Hoeft LO, Karaskiewicz RJ, Hofstra JS, Prather WD, Ayres WR. Effect of charge, feed, and test cable lengths on R2SPG waveforms. In Proceedings of the IEEE International Symposium on Electromagnetic Compatibility, August 1991; 31-36.
-
(1991)
Proceedings of the IEEE International Symposium on Electromagnetic Compatibility
, pp. 31-36
-
-
Hoeft, L.O.1
Karaskiewicz, R.J.2
Hofstra, J.S.3
Prather, W.D.4
Ayres, W.R.5
-
20
-
-
84877940933
-
-
August, Available at
-
Murphy E, Slattery C. Direct digital synthesis (DDS) controls waveforms in tests, measurements, and communications, Analog Dialog, 39-108, August 2005. Available at: http://www.analog.com/library/analogdialogue/archives/38-08/dds. html
-
(2005)
Direct Digital Synthesis (DDS) Controls Waveforms in Tests Measurements and Communications Analog Dialog
, pp. 39-108
-
-
Murphy, E.1
Slattery, C.2
|