메뉴 건너뛰기




Volumn 38, Issue 4, 2010, Pages 1548-1555

A mediated glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring

Author keywords

Amperometric; Biosensors; Ferrocene; Glucose; Reverse Iontophoresis

Indexed keywords

AG/AGCL; AMPEROMETRIC; AMPEROMETRIC BIOSENSORS; AMPEROMETRIC TRANSDUCERS; CURRENT RESPONSE; DROP COATED; ELECTROCHEMICAL CHARACTERISTICS; FERROCENES; GLUCOSE BIOSENSOR; GLUCOSE CONCENTRATION; LINEAR RELATIONSHIPS; LINEAR RESPONSE RANGE; NONINVASIVE GLUCOSE MONITORING; PLANAR CONFIGURATIONS; RESPONSE TIME; REVERSE IONTOPHORESIS; SCREEN PRINTING TECHNIQUE; THREE ELECTRODE;

EID: 77952012087     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-010-9918-4     Document Type: Article
Times cited : (19)

References (58)
  • 1
    • 0027376369 scopus 로고
    • A mediated amperometric enzyme electrode using tetrathiafulvalene and L-glutamate oxidase for the determination of L-glutamic acid
    • DOI 10.1016/0003-2670(93)80221-6
    • NF Almeida AK Mulchandani 1993 A mediated amperometric enzyme electrode using tetrathiafulvalene and l-glutamic acid Anal. Chim. Acta 282 353 361 10.1016/0003-2670(93)80221-6 1:CAS:528:DyaK3sXmsVygsrk%3D (Pubitemid 23300308)
    • (1993) Analytica Chimica Acta , vol.282 , Issue.2 , pp. 353-361
    • Almeida, N.F.1    Mulchandani, A.K.2
  • 3
    • 0001514046 scopus 로고
    • Studies on enzyme electrodes with ferrocene and carbon paste bound with cellulose triacetate
    • 10.1039/an9911600459 1:CAS:528:DyaK3MXisFyrsLk%3D
    • SK Beh GJ Moody JDR Thomas 1991 Studies on enzyme electrodes with ferrocene and carbon paste bound with cellulose triacetate Analyst 116 459 462 10.1039/an9911600459 1:CAS:528:DyaK3MXisFyrsLk%3D
    • (1991) Analyst , vol.116 , pp. 459-462
    • Beh, S.K.1    Moody, G.J.2    Thomas, J.D.R.3
  • 6
    • 0021412692 scopus 로고
    • Ferrocene-mediated enzyme electrode for amperometric determination of glucose
    • 10.1021/ac00268a018 1:CAS:528:DyaL2cXhtFOhurY%3D 6721151
    • AEG Cass D Graham GD Francis, et al. 1984 Ferrocene-mediated enzyme electrode for amperometric determination of glucose Anal. Chem. 56 667 671 10.1021/ac00268a018 1:CAS:528:DyaL2cXhtFOhurY%3D 6721151
    • (1984) Anal. Chem. , vol.56 , pp. 667-671
    • Cass, A.E.G.1    Graham, D.2    Francis, G.D.3
  • 8
    • 18144373420 scopus 로고    scopus 로고
    • A randomized multicenter trial comparing the glucowatch biographer with standard glucose monitoring in children with type 1 diabetes
    • DOI 10.2337/diacare.28.5.1101
    • HP Chase R Beck W Tamborlane, et al. 2005 A randomized multicenter trial comparing the GlucoWatch biographer with standard glucose monitoring in children with type 1 diabetes Diabetes Care 28 1101 1106 10.2337/diacare.28.5.1101 15855573 (Pubitemid 40616619)
    • (2005) Diabetes Care , vol.28 , Issue.5 , pp. 1101-1106
    • Chase, H.P.1
  • 9
    • 17644428053 scopus 로고    scopus 로고
    • A low-cost, programmable device for versatile current delivery in iontophoresis applications
    • DOI 10.1016/j.snb.2004.07.022, PII S0925400504004988
    • CTS Ching I Camilleri P Connolly 2005 A low-cost, programmable device for versatile current delivery in iontophoresis applications Sens. Actuators B Chem. 106 534 540 10.1016/j.snb.2004.07.022 (Pubitemid 40557611)
    • (2005) Sensors and Actuators, B: Chemical , vol.106 , Issue.2 , pp. 534-540
    • Ching, C.T.S.1    Camilleri, I.2    Connolly, P.3
  • 10
    • 38149043456 scopus 로고    scopus 로고
    • A novel diffusion cell ideal for the study of membrane extraction/permeation processes and for device/sensor development
    • 10.1016/j.snb.2007.07.070
    • CTS Ching P Connolly 2008 A novel diffusion cell ideal for the study of membrane extraction/permeation processes and for device/sensor development Sens. Actuators B Chem. 129 30 34 10.1016/j.snb.2007.07.070
    • (2008) Sens. Actuators B Chem. , vol.129 , pp. 30-34
    • Ching, C.T.S.1    Connolly, P.2
  • 11
    • 36348954999 scopus 로고    scopus 로고
    • Glucose biosensors based on electrodes modified with ferrocene derivatives intercalated into Mg/Al layered double hydroxides
    • 10.1002/elan.200703985 1:CAS:528:DC%2BD2sXhsVSnsrrM
    • M Colombari B Ballarin I Carpani, et al. 2007 Glucose biosensors based on electrodes modified with ferrocene derivatives intercalated into Mg/Al layered double hydroxides Electroanalysis 19 2321 2327 10.1002/elan.200703985 1:CAS:528:DC%2BD2sXhsVSnsrrM
    • (2007) Electroanalysis , vol.19 , pp. 2321-2327
    • Colombari, M.1    Ballarin, B.2    Carpani, I.3
  • 12
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    • DOI 10.1016/S0956-5663(99)00024-X, PII S095656639900024X
    • S Cosnier 1999 Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A reviews Biosens. Bioelectron. 14 443 456 10.1016/S0956-5663(99)00024-X 1:CAS:528:DyaK1MXkvVOjtbw%3D 10451912 (Pubitemid 29333569)
    • (1999) Biosensors and Bioelectronics , vol.14 , Issue.5 , pp. 443-456
    • Cosnier, S.1
  • 13
    • 0000073634 scopus 로고
    • Biochemical sensors: The state of art
    • 10.1007/BF01244435
    • M De La Guardia 1995 Biochemical sensors: the state of art Microchim. Acta. 120 243 255 10.1007/BF01244435
    • (1995) Microchim. Acta. , vol.120 , pp. 243-255
    • De La Guardia, M.1
  • 14
    • 0141920471 scopus 로고    scopus 로고
    • Reverse iontophoresis: A non-invasive technique for measuring blood urea level
    • DOI 10.1007/s00467-003-1217-y
    • IT Degim S Ilbasmis R Dundaroz Y Oguz 2003 Reverse iontophoresis: a noninvasive technique for measuring blood urea level Pediatr. Nephrol. 18 1032 1037 10.1007/s00467-003-1217-y 12898373 (Pubitemid 37236218)
    • (2003) Pediatric Nephrology , vol.18 , Issue.10 , pp. 1032-1037
    • Degim, I.T.1    Ilbasmis, S.2    Dundaroz, R.3    Oguz, Y.4
  • 15
    • 1442275324 scopus 로고    scopus 로고
    • Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: Experience of the Diabetes Research in Children Network
    • DOI 10.2337/diacare.27.3.722
    • Diabetes Research in Children Network (DirecNet) Study Group 2004 Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network Diabetes Care 27 722 726 10.2337/diacare.27.3.722 (Pubitemid 38280540)
    • (2004) Diabetes Care , vol.27 , Issue.3 , pp. 722-726
    • Tsalikian, E.1
  • 16
    • 4444379843 scopus 로고    scopus 로고
    • Rates of glucose change measured by blood glucose meter and the gluco watch biographer during day, night, and around mealtimes
    • DOI 10.2337/diacare.27.9.2161
    • TC Dunn RC Eastman JA Tamada 2004 Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes Diabetes Care 27 2161 2165 10.2337/diacare.27.9.2161 1:CAS:528:DC%2BD2cXnvFKrsbs%3D 15333478 (Pubitemid 39167179)
    • (2004) Diabetes Care , vol.27 , Issue.9 , pp. 2161-2165
    • Dunn, T.C.1    Eastman, R.C.2    Tamada, J.A.3
  • 18
    • 10444277456 scopus 로고    scopus 로고
    • Electrochemical evaluation of ferrocene carboxylic acids confined on surfactant-clay modified glassy carbon electrodes: Oxidation of ascorbic acid and uric acid
    • 10.1016/j.electacta.2004.08.016 1:CAS:528:DC%2BD2cXhtVCitrnJ
    • L Fernandez H Carrero 2005 Electrochemical evaluation of ferrocene carboxylic acids confined on surfactant-clay modified glassy carbon electrodes: oxidation of ascorbic acid and uric acid Electrochim. Acta 50 1233 1240 10.1016/j.electacta.2004.08.016 1:CAS:528:DC%2BD2cXhtVCitrnJ
    • (2005) Electrochim. Acta , vol.50 , pp. 1233-1240
    • Fernandez, L.1    Carrero, H.2
  • 19
    • 21244434882 scopus 로고    scopus 로고
    • Eight-point glucose testing Versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes
    • DOI 10.1210/jc.2004-2510
    • R Fiallo-Scharer Diabetes Research in Children Network Study Group 2005 Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in Type 1 diabetes J. Clin. Endocrinol. Metab. 90 3387 3391 10.1210/jc.2004-2510 15784705 (Pubitemid 41014302)
    • (2005) Journal of Clinical Endocrinology and Metabolism , vol.90 , Issue.6 , pp. 3387-3391
    • Fiallo-Scharer, R.1
  • 20
    • 0347079829 scopus 로고    scopus 로고
    • Amperometric biosensor based on the co-immobilization of glucose oxidase (GOx) and ferrocene in poly(pyrrole) generated from ethanol/water mixtures
    • 10.1590/S0103-50532001000600007 1:CAS:528:DC%2BD3MXos1ansrY%3D
    • PA Fiorito SI Córdoba de Torresi 2001 Amperometric biosensor based on the co-immobilization of glucose oxidase (GOx) and ferrocene in poly(pyrrole) generated from ethanol/water mixtures J. Braz. Chem. Soc. 12 729 733 10.1590/S0103-50532001000600007 1:CAS:528:DC%2BD3MXos1ansrY%3D
    • (2001) J. Braz. Chem. Soc. , vol.12 , pp. 729-733
    • Fiorito, P.A.1    Torresi De Córdoba, S.I.2
  • 21
    • 0032179664 scopus 로고    scopus 로고
    • Glucose biosensor strip in a three electrode configuration based on composite and biocomposite materials applied by planar thick film technology
    • 10.1016/S0925-4005(98)00276-7
    • CA Galan-Vidal J Munoz C Dominguez, et al. 1998 Glucose biosensor strip in a three electrode configuration based on composite and biocomposite materials applied by planar thick film technology Sens. Actuators B Chem. 52 257 263 10.1016/S0925-4005(98)00276-7
    • (1998) Sens. Actuators B Chem. , vol.52 , pp. 257-263
    • Galan-Vidal, C.A.1    Munoz, J.2    Dominguez, C.3
  • 23
    • 0032882086 scopus 로고    scopus 로고
    • Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
    • DOI 10.2337/diacare.22.10.1708
    • SK Garg RO Potts NR Ackerman, et al. 1999 Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with Type 1 diabetes Diabetes Care 22 1708 1714 10.2337/diacare.22.10. 1708 1:STN:280:DyaK1MvlsFKlsg%3D%3D 10526740 (Pubitemid 29458398)
    • (1999) Diabetes Care , vol.22 , Issue.10 , pp. 1708-1714
    • Garg, S.K.1    Potts, R.O.2    Ackerman, N.R.3    Fermi, S.J.4    Tamada, J.A.5    Chase, H.P.6
  • 24
    • 18044367934 scopus 로고    scopus 로고
    • Development of a carbon film electrode ferrocene-mediated glucose biosensor
    • 1:CAS:528:DC%2BD2MXktFSru7Y%3D
    • ME Ghica CMA Brett 2005 Development of a carbon film electrode ferrocene-mediated glucose biosensor Anal. Lett. 38 907 920 1:CAS:528: DC%2BD2MXktFSru7Y%3D
    • (2005) Anal. Lett. , vol.38 , pp. 907-920
    • Ghica, M.E.1    Brett, C.M.A.2
  • 25
    • 0025306487 scopus 로고
    • Carbon paste tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing systems
    • 10.1039/an9901500035 1:CAS:528:DyaK3cXhslCqtLs%3D 2334056
    • H Gunasingham CH Tan 1990 Carbon paste tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing systems Analyst 115 35 39 10.1039/an9901500035 1:CAS:528:DyaK3cXhslCqtLs%3D 2334056
    • (1990) Analyst , vol.115 , pp. 35-39
    • Gunasingham, H.1    Tan, C.H.2
  • 26
    • 0028854253 scopus 로고
    • Characterization of inhibitors of acetylcholinesterase by an automated amperometric flow-injection system
    • 10.1016/0003-2670(94)00352-M
    • A Gunther U Bilitewski 1995 Characterization of inhibitors of acetylcholinesterase by an automated amperometric flow-injection system Anal. Chim. Acta 300 117 125 10.1016/0003-2670(94)00352-M
    • (1995) Anal. Chim. Acta , vol.300 , pp. 117-125
    • Gunther, A.1    Bilitewski, U.2
  • 27
    • 0025891986 scopus 로고
    • Investigation of violgen dericatives as electron-transfer mediators in amperometric glucose sensors
    • 10.1016/S0003-2670(00)80879-X
    • PD Hale LI Boguslavsky HI Karan, et al. 1991 Investigation of violgen dericatives as electron-transfer mediators in amperometric glucose sensors Anal. Chim. Acta 249 155 161 10.1016/S0003-2670(00)80879-X
    • (1991) Anal. Chim. Acta , vol.249 , pp. 155-161
    • Hale, P.D.1    Boguslavsky, L.I.2    Karan, H.I.3
  • 29
    • 56449094732 scopus 로고    scopus 로고
    • Electroosmotic flow and its contribution to iontophoretic delivery
    • 10.1021/ac801547a 1:CAS:528:DC%2BD1cXht1yitbvO 18947198
    • NR Herr BM Kile RM Carelli RM Wightman 2008 Electroosmotic flow and its contribution to iontophoretic delivery Anal. Chem. 80 8635 8641 10.1021/ac801547a 1:CAS:528:DC%2BD1cXht1yitbvO 18947198
    • (2008) Anal. Chem. , vol.80 , pp. 8635-8641
    • Herr, N.R.1    Kile, B.M.2    Carelli, R.M.3    Wightman, R.M.4
  • 30
    • 0000983719 scopus 로고
    • Screen printed enzyme electrode for the determination of lactose
    • 10.1039/an9941901251
    • A Jager U Bilitewski 1994 Screen printed enzyme electrode for the determination of lactose Analyst 119 1251 1255 10.1039/an9941901251
    • (1994) Analyst , vol.119 , pp. 1251-1255
    • Jager, A.1    Bilitewski, U.2
  • 31
    • 0000072440 scopus 로고    scopus 로고
    • Design of enzyme electrodes for extended use and storage life
    • 10.1021/ac961208z 1:CAS:528:DyaK2sXjvVChtLY%3D
    • GF Khan W Wernet 1997 Design of enzyme electrodes for extended use and storage life Anal. Chem. 69 2682 2687 10.1021/ac961208z 1:CAS:528: DyaK2sXjvVChtLY%3D
    • (1997) Anal. Chem. , vol.69 , pp. 2682-2687
    • Khan, G.F.1    Wernet, W.2
  • 32
    • 0032287738 scopus 로고    scopus 로고
    • Design and simulation of a reverse iontophoretic glucose monitoring device
    • RT Kurnik B Berner J Tamada RO Potts 1998 Design and simulation of a reverse iontophoretic glucose monitoring device J. Electrochem. Soc. 145 4119 4125 10.1149/1.1838924 1:CAS:528:DyaK1cXnsl2iur0%3D (Pubitemid 128594942)
    • (1998) Journal of the Electrochemical Society , vol.145 , Issue.12 , pp. 4119-4125
    • Kurnik, R.T.1    Berner, B.2    Tamada, J.3    Potts, R.O.4
  • 35
    • 33745023790 scopus 로고    scopus 로고
    • Glucose biosensor based on carbon/PVC-COOH/ferrocene composite with covalently immobilized enzyme
    • 1:CAS:528:DC%2BD2MXht1Sit7fO
    • CX Li YL Zeng CR Tang 2005 Glucose biosensor based on carbon/PVC-COOH/ferrocene composite with covalently immobilized enzyme Chin. Chem. Lett. 16 1357 1360 1:CAS:528:DC%2BD2MXht1Sit7fO
    • (2005) Chin. Chem. Lett. , vol.16 , pp. 1357-1360
    • Li, C.X.1    Zeng, Y.L.2    Tang, C.R.3
  • 36
    • 0032029923 scopus 로고    scopus 로고
    • Analytical strategies for amperometric biosensors based on chemically modified electrodes
    • DOI 10.1016/S0956-5663(97)00138-3, PII S0956566397001383
    • E Lorenzo F Pariente L Hernandez, et al. 1998 Analytical strategies for amperometric biosensors based on chemically modified electrodes Biosens. Bioelectron. 13 319 332 10.1016/S0956-5663(97)00138-3 1:CAS:528: DyaK1cXjs1KmsrY%3D 9642768 (Pubitemid 28238357)
    • (1998) Biosensors and Bioelectronics , vol.13 , Issue.3-4 , pp. 319-332
    • Lorenzo, E.1    Pariente, F.2    Hernandez, L.3    Tobalina, F.4    Darder, M.5    Wu, Q.6    Maskus, M.7    Abruna, H.D.8
  • 37
    • 0029256737 scopus 로고
    • A glucose biosensor fabricated by the screen printing technique
    • 10.1016/0956-5663(95)96845-P 1:CAS:528:DyaK2MXltF2rt7o%3D
    • R Nagata K Yokoyama SA Clark I Karube 1995 A glucose biosensor fabricated by the screen printing technique Biosensens. Bioelectron. 10 261 267 10.1016/0956-5663(95)96845-P 1:CAS:528:DyaK2MXltF2rt7o%3D
    • (1995) Biosensens. Bioelectron. , vol.10 , pp. 261-267
    • Nagata, R.1    Yokoyama, K.2    Clark, S.A.3    Karube, I.4
  • 38
    • 0040401549 scopus 로고
    • Theory of stationary electrode polarography. Single scan and cyclic methods applied to reversible, irreversible, and kinetic systems
    • 10.1021/ac60210a007 1:CAS:528:DyaF2cXktV2ms7s%3D
    • RS Nicholson I Shain 1964 Theory of stationary electrode polarography. Single scan and cyclic methods applied to reversible, irreversible, and kinetic systems Anal. Chem. 36 706 723 10.1021/ac60210a007 1:CAS:528:DyaF2cXktV2ms7s%3D
    • (1964) Anal. Chem. , vol.36 , pp. 706-723
    • Nicholson, R.S.1    Shain, I.2
  • 40
    • 4344582891 scopus 로고    scopus 로고
    • Use of the noninvasive GlucoWatch® Biographer® during exercise of varying intensity
    • DOI 10.1089/1520915041705848
    • T Nunnold SR Colberg MT Herriott CT Somma 2004 Use of the noninvasive GlucoWatch Biographer during exercise of varying intensity Diabetes Technol. Ther. 6 454 462 10.1089/1520915041705848 15320999 (Pubitemid 39121369)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.4 , pp. 454-462
    • Nunnold, T.1    Colberg, S.R.2    Herriott, M.T.3    Somma, C.T.4
  • 41
    • 33749100022 scopus 로고    scopus 로고
    • Tethered mediator biosensor: The concept and the preliminary results
    • 1:CAS:528:DyaK2sXjsleiu74%3D
    • Y Okawa M Nagano H Kobayashi, et al. 1997 Tethered mediator biosensor: the concept and the preliminary results Denki Kagaku Oyobi Kougyou Butsuri Kagaku 65 504 505 1:CAS:528:DyaK2sXjsleiu74%3D
    • (1997) Denki Kagaku Oyobi Kougyou Butsuri Kagaku , vol.65 , pp. 504-505
    • Okawa, Y.1    Nagano, M.2    Kobayashi, H.3
  • 42
    • 0037756782 scopus 로고    scopus 로고
    • Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase modified graphite paste electrode
    • DOI 10.1016/S0956-5663(03)00075-7
    • PC Pandey S Upadhyay NK Shukla S Sharma 2003 Studies on the electrochemical performance of glucose biosensor based on ferrocene encapsulated ORMOSIL and glucose oxidase Biosens. Bioelectron. 18 1257 1268 10.1016/S0956-5663(03)00075-7 1:CAS:528:DC%2BD3sXkvFGkt7o%3D 12835044 (Pubitemid 36776587)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.10 , pp. 1257-1268
    • Pandey, P.C.1    Upadhyay, S.2    Shukla, N.K.3    Sharma, S.4
  • 43
    • 0035345431 scopus 로고    scopus 로고
    • Detection of hypoglycaemia with the GlucoWatch biographer
    • 10.2337/diacare.24.5.881 1:STN:280:DC%2BD3MrhsFOnug%3D%3D 11347748
    • KR Pitzer S Desai T Dunn, et al. 2001 Detection of hypoglycaemia with the GlucoWatch biographer Diabetes Care 24 881 885 10.2337/diacare.24.5.881 1:STN:280:DC%2BD3MrhsFOnug%3D%3D 11347748
    • (2001) Diabetes Care , vol.24 , pp. 881-885
    • Pitzer, K.R.1    Desai, S.2    Dunn, T.3
  • 44
  • 46
    • 33748689293 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and highly selective voltammetric determination of l-cysteine at the surface of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon paste electrode
    • 10.2116/analsci.22.1213 1:CAS:528:DC%2BD28XhtVanu7jJ 16966812
    • JB Raoof R Ojani H Beitollahi R Hossienzadeh 2006 Electrocatalytic oxidation and highly selective voltammetric determination of l-cysteine at the surface of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon paste electrode Anal. Sci. 22 1213 1221 10.2116/analsci.22.1213 1:CAS:528: DC%2BD28XhtVanu7jJ 16966812
    • (2006) Anal. Sci. , vol.22 , pp. 1213-1221
    • Raoof, J.B.1    Ojani, R.2    Beitollahi, H.3    Hossienzadeh, R.4
  • 47
    • 33745557475 scopus 로고    scopus 로고
    • Electrocatalytic determination of ascorbic acid at the surface of 2,7-bis(ferrocenyl ethyl)fluoren-9-one modified carbon paste electrode
    • 10.1002/elan.200503516 1:CAS:528:DC%2BD28XmsVOhsrs%3D
    • JB Raoof R Ojani H Beitollahi R Hossienzadeh 2006 Electrocatalytic determination of ascorbic acid at the surface of 2,7-bis(ferrocenyl ethyl)fluoren-9-one modified carbon paste electrode Electroanalysis 18 1193 1201 10.1002/elan.200503516 1:CAS:528:DC%2BD28XmsVOhsrs%3D
    • (2006) Electroanalysis , vol.18 , pp. 1193-1201
    • Raoof, J.B.1    Ojani, R.2    Beitollahi, H.3    Hossienzadeh, R.4
  • 48
    • 3242759069 scopus 로고    scopus 로고
    • Noninvasive glucose monitoring by reverse iontophoresis in vivo: Application of the internal standard concept
    • DOI 10.1373/clinchem.2004.032862
    • A Sieg RH Guy MB Delgado-Charro 2004 Noninvasive glucose monitoring by reverse iontophoresis in vivo: application of the internal standard concept Clin. Chem. 50 1383 1390 10.1373/clinchem.2004.032862 1:CAS:528: DC%2BD2cXmtFKgu7s%3D 15155544 (Pubitemid 38970646)
    • (2004) Clinical Chemistry , vol.50 , Issue.8 , pp. 1383-1390
    • Sieg, A.1    Guy, R.H.2    Delgado-Charro, M.B.3
  • 49
    • 0028823945 scopus 로고
    • Measurement of glucose in diabetic subjects using noninvasive glucose extraction
    • 10.1038/nm1195-1198 1:CAS:528:DyaK2MXptFahsL0%3D 7584995
    • JA Tamada NJ Bohannon RO Potts 1995 Measurement of glucose in diabetic subjects using noninvasive glucose extraction Nat. Med. 1 1198 1201 10.1038/nm1195-1198 1:CAS:528:DyaK2MXptFahsL0%3D 7584995
    • (1995) Nat. Med. , vol.1 , pp. 1198-1201
    • Tamada, J.A.1    Bohannon, N.J.2    Potts, R.O.3
  • 50
    • 0033579205 scopus 로고    scopus 로고
    • Noninvasive glucose monitoring: Comprehensive clinical results. Cygnus Research Team
    • 10.1001/jama.282.19.1839 1:STN:280:DC%2BD3c%2Fjsl2ntA%3D%3D 10573275
    • JA Tamada S Garg L Jovanovic, et al. 1999 Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team JAMA 282 1839 1844 10.1001/jama.282.19.1839 1:STN:280:DC%2BD3c%2Fjsl2ntA%3D%3D 10573275
    • (1999) JAMA , vol.282 , pp. 1839-1844
    • Tamada, J.A.1    Garg, S.2    Jovanovic, L.3
  • 52
    • 0000994919 scopus 로고    scopus 로고
    • Design of a biosensor for continual, transdermal glucose monitoring
    • 10471687
    • MJ Tierney Y Jayalakshmi NA Parris, et al. 1999 Design of a biosensor for continual, transdermal glucose monitoring Clin. Chem. 45 1681 1683 10471687
    • (1999) Clin. Chem. , vol.45 , pp. 1681-1683
    • Tierney, M.J.1    Jayalakshmi, Y.2    Parris, N.A.3
  • 53
    • 0034780892 scopus 로고    scopus 로고
    • Clinical evaluation of the GlucoWatch® biographer: A continual, non-invasive glucose monitor for patients with diabetes
    • DOI 10.1016/S0956-5663(01)00189-0, PII S0956566301001890
    • ® biographer: a continual, non-invasive glucose monitor for patients with diabetes Biosens. Bioelectron. 16 621 629 10.1016/S0956-5663(01)00189-0 1:CAS:528:DC%2BD3MXnslenu7o%3D 11679237 (Pubitemid 33000190)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.9-12 , pp. 621-629
    • Tierney, M.J.1    Tamada, J.A.2    Potts, R.O.3    Jovanovic, L.4    Garg, S.5
  • 54
    • 6044276738 scopus 로고    scopus 로고
    • GlucoWatch® G2™ biographer alarm reliability during hypoglycemia in children
    • DOI 10.1089/dia.2004.6.559
    • E Tsalikian C Kollman N Mauras, et al. 2004 GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children Diabetes Technol. Ther. 6 559 566 10.1089/dia.2004.6.559 15628809 (Pubitemid 39383063)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.5 , pp. 559-566
    • Tsalikian, E.1
  • 55
    • 0005432467 scopus 로고
    • Mediated enzyme electrode for the determination of l-glutamate
    • 1:CAS:528:DyaK3MXlvVWltbo%3D
    • W Vahjen J Bradley U Bilitewski, et al. 1991 Mediated enzyme electrode for the determination of l-glutamate Anal. Lett. 24 1445 1452 1:CAS:528:DyaK3MXlvVWltbo%3D
    • (1991) Anal. Lett. , vol.24 , pp. 1445-1452
    • Vahjen, W.1    Bradley, J.2    Bilitewski, U.3
  • 56
    • 0029883580 scopus 로고    scopus 로고
    • Development of a mass-producible glucose biosensor and flow-injection analysis system suitable for on-line monitoring during fermentations
    • DOI 10.1016/0003-2670(95)00514-5
    • SF White IE Tothill JD Newman APF Turner 1996 Development of a mass-producible glucose biosensor and flow-injection analysis system suitable for on line monitoring during fermentations Anal. Chim. Acta 321 165 172 10.1016/0003-2670(95)00514-5 1:CAS:528:DyaK28XhsFOjtr4%3D (Pubitemid 26084992)
    • (1996) Analytica Chimica Acta , vol.321 , Issue.2-3 , pp. 165-172
    • White, S.F.1    Tothill, I.E.2    Newman, J.D.3    Turner, A.P.F.4
  • 57
    • 0030175963 scopus 로고    scopus 로고
    • Glucose monitoring: State of the art and future possibilities
    • DOI 10.1016/1350-4533(95)00046-1
    • E Wilkins P Atanasov 1996 Glucose monitoring: state of the art and future possibilities Med. Eng. Phys. 18 273 288 10.1016/1350-4533(95)00046-1 1:STN:280:DyaK28znsFyqtQ%3D%3D 8782186 (Pubitemid 26185094)
    • (1996) Medical Engineering and Physics , vol.18 , Issue.4 , pp. 273-288
    • Wilkins, E.1    Atanasov, P.2
  • 58
    • 33751428057 scopus 로고    scopus 로고
    • A ferrocene-mediated anti-interfering glucose biosensor based on glutin and cellulose acetate
    • 1:CAS:528:DC%2BD28XhtFKqu7fO
    • BY Wu J Li HB Shi, et al. 2006 A ferrocene-mediated anti-interfering glucose biosensor based on glutin and cellulose acetate High Technol. Lett. 12 263 266 1:CAS:528:DC%2BD28XhtFKqu7fO
    • (2006) High Technol. Lett. , vol.12 , pp. 263-266
    • Wu, B.Y.1    Li, J.2    Shi, H.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.