메뉴 건너뛰기




Volumn 94, Issue 2, 2010, Pages

Use of optical coherence tomography for accurate characterization of atherosclerosis;Uso de la tomografía de coherencia óptica intracoronaria para caracterización precisa de la aterosclerosis

Author keywords

Atherosclerosis; Intravascular imaging; Optical coherence tomography

Indexed keywords

ATHEROSCLEROSIS; BLOOD VESSEL REACTIVITY; CARDIOLOGIST; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HUMAN; IN VIVO STUDY; INTIMA; INTRAVASCULAR ULTRASOUND; OPTICAL COHERENCE TOMOGRAPHY; REVIEW;

EID: 77952002808     PISSN: 0066782X     EISSN: 16784170     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (16)

References (25)
  • 2
    • 41949137318 scopus 로고    scopus 로고
    • Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting
    • Yamagushi M, Terashima M, Akasaka T, Hayashi T, Mizuno K, Muramatsu T, et al. Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. Am J Cardiol. 2008; 101: 562-567
    • (2008) Am J Cardiol , vol.101 , pp. 562-567
    • Yamagushi, M.1    Terashima, M.2    Akasaka, T.3    Hayashi, T.4    Mizuno, K.5    Muramatsu, T.6
  • 3
    • 0037138571 scopus 로고    scopus 로고
    • Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound
    • Jang IK, Bouma BE, Kang DH, Park SJ, Park SW, Seung KB, et al. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol. 2002; 39: 604-609
    • (2002) J Am Coll Cardiol , vol.39 , pp. 604-609
    • Jang, I.K.1    Bouma, B.E.2    Kang, D.H.3    Park, S.J.4    Park, S.W.5    Seung, K.B.6
  • 4
    • 26444450457 scopus 로고    scopus 로고
    • In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: A comparison with intravascular ultrasound
    • Kawase Y, Hoshino K, Yoneyama R, McGregor J, Hajjar RJ, Jang IK, et al. In vivo volumetric analysis of coronary stent using optical coherence tomography with a novel balloon occlusion-flushing catheter: a comparison with intravascular ultrasound. Ultrasound Med Biol. 2005; 31: 1343-1349
    • (2005) Ultrasound Med Biol , vol.31 , pp. 1343-1349
    • Kawase, Y.1    Hoshino, K.2    Yoneyama, R.3    McGregor, J.4    Hajjar, R.J.5    Jang, I.K.6
  • 5
    • 23744458331 scopus 로고    scopus 로고
    • Assessment of coronary intima-media thickness by optical coherence tomography: Comparison with intravascular ultrasound
    • Kume T, Akasaka T, Kawamoto T, Watanabe N, Toyota E, Neishi Y, et al. Assessment of coronary intima-media thickness by optical coherence tomography: comparison with intravascular ultrasound. Circ J. 2005; 69: 903-907
    • (2005) Circ J , vol.69 , pp. 903-907
    • Kume, T.1    Akasaka, T.2    Kawamoto, T.3    Watanabe, N.4    Toyota, E.5    Neishi, Y.6
  • 6
    • 0242322532 scopus 로고    scopus 로고
    • Optical coherence tomography for ultrahigh resolution in vivo imaging
    • Fujimoto JG. Optical coherence tomography for ultrahigh resolution in vivo imaging. Nat Biotechnol. 2003; 21: 1361-1367
    • (2003) Nat Biotechnol , vol.21 , pp. 1361-1367
    • Fujimoto, J.G.1
  • 7
    • 33947514493 scopus 로고    scopus 로고
    • Optical coherence tomography accurately identifies intermediate atherosclerotic lesions - An in vivo evaluation in the rabbit carotid artery
    • Zimarino M, Prati F, Pizzicannella ESJ, Fouad T, Filippini A, Rabozzi R, et al. Optical coherence tomography accurately identifies intermediate atherosclerotic lesions - An in vivo evaluation in the rabbit carotid artery. Atherosclerosis. 2007; 193: 94-101.
    • (2007) Atherosclerosis , vol.193 , pp. 94-101
    • Zimarino, M.1    Prati, F.2    Pizzicannella, E.S.J.3    Fouad, T.4    Filippini, A.5    Rabozzi, R.6
  • 9
    • 0034019601 scopus 로고    scopus 로고
    • Lessons from sudden coronary death: A comprehensive morphological classification scheme for atherosclerotic lesions
    • Virmani R, Kolodgie FD, Burke AP, Farb A, Schwartz SM. Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol. 2000; 20: 1262-1275
    • (2000) Arterioscler Thromb Vasc Biol , vol.20 , pp. 1262-1275
    • Virmani, R.1    Kolodgie, F.D.2    Burke, A.P.3    Farb, A.4    Schwartz, S.M.5
  • 10
    • 0030961921 scopus 로고    scopus 로고
    • Coronary risk factors and plaque morphology in men with coronary disease who died suddenly
    • Burke AP, Farb A, Malcom GT, Liang YH, Smialek J, Virmani R. Coronary risk factors and plaque morphology in men with coronary disease who died suddenly. N Engl J Med. 1997; 336: 1276-1282
    • (1997) N Engl J Med , vol.336 , pp. 1276-1282
    • Burke, A.P.1    Farb, A.2    Malcom, G.T.3    Liang, Y.H.4    Smialek, J.5    Virmani, R.6
  • 11
    • 33748684390 scopus 로고    scopus 로고
    • Measurement of the thickness of the fibrous cap by optical coherence tomography
    • Kume T, Akasaka T, Kawamoto T, Okura H, Watanabe N, Toyota E, et al. Measurement of the thickness of the fibrous cap by optical coherence tomography. Am Heart J. 2006; 152 (4): 755 e1-4.
    • (2006) Am Heart J , vol.152 , Issue.4
    • Kume, T.1    Akasaka, T.2    Kawamoto, T.3    Okura, H.4    Watanabe, N.5    Toyota, E.6
  • 12
    • 40949105534 scopus 로고    scopus 로고
    • Relationship between coronary remodeling and plaque characterization in patients without clinical evidence of coronary artery disease
    • Kume T, Okura H, Kawamoto T, Akasaka T, Toyota E, Watanabe N, et al. Relationship between coronary remodeling and plaque characterization in patients without clinical evidence of coronary artery disease. Atherosclerosis. 2008; 197 (2): 799-805.
    • (2008) Atherosclerosis , vol.197 , Issue.2 , pp. 799-805
    • Kume, T.1    Okura, H.2    Kawamoto, T.3    Akasaka, T.4    Toyota, E.5    Watanabe, N.6
  • 13
    • 0029876139 scopus 로고    scopus 로고
    • Coronary plaque erosion without rupture into a lipid core: A frequent cause of coronary thrombosis in sudden coronary death
    • Farb A, Burke AP, Tang AL, Liang TY, Mannan P, Smialek J, et al. Coronary plaque erosion without rupture into a lipid core: a frequent cause of coronary thrombosis in sudden coronary death. Circulation. 1996; 93: 1354-1363
    • (1996) Circulation , vol.93 , pp. 1354-1363
    • Farb, A.1    Burke, A.P.2    Tang, A.L.3    Liang, T.Y.4    Mannan, P.5    Smialek, J.6
  • 14
    • 4444281029 scopus 로고    scopus 로고
    • Focal and multi-focal plaque macrophagedistributions in patients with acute and stable presentations of coronary artery disease
    • MacNeill BD, Jang IK, Bouma BE, Iftimia N, Takano M, Yabushita H, et al. Focal and multi-focal plaque macrophagedistributions in patients with acute and stable presentations of coronary artery disease. J Am Coll Cardiol. 2004; 44 (5): 972-979
    • (2004) J Am Coll Cardiol , vol.44 , Issue.5 , pp. 972-979
    • MacNeill, B.D.1    Jang, I.K.2    Bouma, B.E.3    Iftimia, N.4    Takano, M.5    Yabushita, H.6
  • 16
    • 44349145439 scopus 로고    scopus 로고
    • In vivo optical coherence tomography (OCT) of experimental thrombosis in a rabbit carotid model
    • Meng L, Lu B, Zhang S, Yv B. In vivo optical coherence tomography (OCT) of experimental thrombosis in a rabbit carotid model. Heart. 2008; 94 (6): 777-780
    • (2008) Heart , vol.94 , Issue.6 , pp. 777-780
    • Meng, L.1    Lu, B.2    Zhang, S.3    Yv, B.4
  • 19
    • 50849114387 scopus 로고    scopus 로고
    • Validation of a novel automated optical coherence tomography analysis system for evaluation of vascular healing after des implantation
    • Suzuki Y, Guagliumi G, Sirbu V, Suzuki N, Friedman J, Steinbrecher R, et al. Validation of a novel automated optical coherence tomography analysis system for evaluation of vascular healing after DES implantation. Am J Cardiol. 2007; 100: 140L.
    • (2007) Am J Cardiol , vol.100
    • Suzuki, Y.1    Guagliumi, G.2    Sirbu, V.3    Suzuki, N.4    Friedman, J.5    Steinbrecher, R.6
  • 20
    • 40749148045 scopus 로고    scopus 로고
    • Intravascular optimal coherence tomography: Optimisation of image acquisition and quantitative assessment of stent strut apposition
    • Tanigawa J, Barlis P, Di Mario C. Intravascular optimal coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. Eurointerv. 2007; 3: 128-136
    • (2007) Eurointerv , vol.3 , pp. 128-136
    • Tanigawa, J.1    Barlis, P.2    Di Mario, C.3
  • 21
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by Optical Coherence Tomography of Neointimal Coverage of Sirolimus-Eluting Stent Three Months after Implantation
    • DOI 10.1016/j.amjcard.2006.11.068, PII S0002914907000781
    • Takano M, Inami S, Jang IK, Yamamoto M, Murakami D, Seimiya K, et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol. 2007; 99 (8): 1033-1038 (Pubitemid 46560470)
    • (2007) American Journal of Cardiology , vol.99 , Issue.8 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.-K.3    Yamamoto, M.4    Murakami, D.5    Seimiya, K.6    Ohba, T.7    Mizuno, K.8
  • 22
    • 51749118724 scopus 로고    scopus 로고
    • Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation
    • Xie Y, Takano M, Yamamoto M, Okamatsu K, Inami S, Seimiya K, et al. Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation. Am J Cardiol. 2008; 102 (1): 27-31.
    • (2008) Am J Cardiol , vol.102 , Issue.1 , pp. 27-31
    • Xie, Y.1    Takano, M.2    Yamamoto, M.3    Okamatsu, K.4    Inami, S.5    Seimiya, K.6
  • 23
    • 64849111067 scopus 로고    scopus 로고
    • Various optical coherence tomographic findings in restenotic lesions after sirolimus-eluting stent implantation
    • Takano M, Xie Y, Murakami D, Inami S, Yamamoto M, Ohba T, et al. Various optical coherence tomographic findings in restenotic lesions after sirolimus-eluting stent implantation. Int J Cardiol. 2009; 134 (2): 263-265
    • (2009) Int J Cardiol , vol.134 , Issue.2 , pp. 263-265
    • Takano, M.1    Xie, Y.2    Murakami, D.3    Inami, S.4    Yamamoto, M.5    Ohba, T.6
  • 24
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: Strut coverage as a marker of endothelialization
    • DOI 10.1161/CIRCULATIONAHA.107.693739
    • Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007; 115: 2435-2441 (Pubitemid 46717966)
    • (2007) Circulation , vol.115 , Issue.18 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3    Kolodgie, F.4    Newell, J.5    John, M.C.6    Gold, H.K.7    Virmani, R.8
  • 25
    • 39549105785 scopus 로고    scopus 로고
    • Longterm follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: Do uncovered struts persist?
    • Takano M, Yamamoto M, Inami S, Murakami D, Seimiya K, Ohba T, et al. Longterm follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: do uncovered struts persist? J Am Coll Cardiol. 2008; 51 (9): 968-969
    • (2008) J Am Coll Cardiol , vol.51 , Issue.9 , pp. 968-969
    • Takano, M.1    Yamamoto, M.2    Inami, S.3    Murakami, D.4    Seimiya, K.5    Ohba, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.