메뉴 건너뛰기




Volumn 17, Issue 5, 2010, Pages 862-869

Interlaboratory comparison of three multiplexed bead-based immunoassays for measuring serum antibodies to pneumococcal polysaccharides

Author keywords

[No Author keywords available]

Indexed keywords

IMMUNOGLOBULIN G ANTIBODY; PNEUMOCOCCUS VACCINE;

EID: 77951988546     PISSN: 15566811     EISSN: 1556679X     Source Type: Journal    
DOI: 10.1128/CVI.00022-10     Document Type: Article
Times cited : (35)

References (18)
  • 2
    • 0035099207 scopus 로고    scopus 로고
    • Pneumococcal type 22F polysaccharide absorption improves the specificity of a pneumococcal-polysaccharide enzyme-linked immunosorbent assay
    • Concepcion, N. F., and C. E. Frasch. 2001. Pneumococcal type 22F polysaccharide absorption improves the specificity of a pneumococcal- polysaccharide enzyme-linked immunosorbent assay. Clin. Diagn. Lab. Immunol. 8:266-272.
    • (2001) Clin. Diagn. Lab. Immunol. , vol.8 , pp. 266-272
    • Concepcion, N.F.1    Frasch, C.E.2
  • 4
    • 12944278736 scopus 로고    scopus 로고
    • Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypes
    • DOI 10.1016/j.jim.2004.11.006, PII S0022175904003783
    • Lal, G., P. Balmer, E. Stanford, S. Martin, R. Warrington, and R. Borrow. 2005. Development and validation of a nonaplex assay for the simultaneous quantitation of antibodies to nine Streptococcus pneumoniae serotypes. J. Immunol. Methods 296:135-147. (Pubitemid 40174747)
    • (2005) Journal of Immunological Methods , vol.296 , Issue.1-2 , pp. 135-147
    • Lal, G.1    Balmer, P.2    Stanford, E.3    Martin, S.4    Warrington, R.5    Borrow, R.6
  • 5
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin, L. I. K. 1989. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.K.1
  • 6
    • 0031968848 scopus 로고    scopus 로고
    • Coefficient of accuracy and concordance correlation coefficient: New statistics for methods comparison
    • Lin, L., and L. D. Torbeck. 1998. Coefficient of accuracy and concordance correlation coefficient: new statistics for methods comparison. PDA J. Pharm. Sci. Technol. 52:55-59.
    • (1998) PDA J. Pharm. Sci. Technol. , vol.52 , pp. 55-59
    • Lin, L.1    Torbeck, L.D.2
  • 8
    • 61949238873 scopus 로고    scopus 로고
    • Optimization and validation of a multiplex, electrochemiluminescence- based detection assay for the quantitation of immunoglobulin G serotype-specific antipneumococcal antibodies in human serum
    • Marchese, R. D., D. Puchalski, P. Miller, J. Antonello, O. Hammond, T. Green, L. J. Rubinstein, M. J. Caulfield, and D. Sikkema. 2009. Optimization and validation of a multiplex, electrochemiluminescence-based detection assay for the quantitation of immunoglobulin G serotype-specific antipneumococcal antibodies in human serum. Clin. Vaccine Immunol. 16:387-396.
    • (2009) Clin. Vaccine Immunol. , vol.16 , pp. 387-396
    • Marchese, R.D.1    Puchalski, D.2    Miller, P.3    Antonello, J.4    Hammond, O.5    Green, T.6    Rubinstein, L.J.7    Caulfield, M.J.8    Sikkema, D.9
  • 10
    • 37049236408 scopus 로고
    • Determination of the coefficient of correlation
    • Pearson, K. 1909. Determination of the coefficient of correlation. Science 30:23-25.
    • (1909) Science , vol.30 , pp. 23-25
    • Pearson, K.1
  • 14
    • 31944434716 scopus 로고    scopus 로고
    • A novel chemistry for conjugating pneumococcal polysaccharides to Luminex microspheres
    • Schlottmann, S. A., N. Jain, N. Chirmule, and M. T. Esser. 2006. A novel chemistry for conjugating pneumococcal polysaccharides to Luminex microspheres. J. Immunol. Methods 309:75-85.
    • (2006) J. Immunol. Methods , vol.309 , pp. 75-85
    • Schlottmann, S.A.1    Jain, N.2    Chirmule, N.3    Esser, M.T.4
  • 15
    • 69849100313 scopus 로고    scopus 로고
    • Evaluation of the specificity of pneumococcal polysaccharide enzyme-linked immunosorbent assay and effect of serum adsorption based on standard pneumococcal serogroup- Or serotype-specific rabbit antisera
    • Slotved, H. C., C. Gluttmann, C. D. Pedersen, J. N. Jacobsen, and K. A. Krogfelt. 2009. Evaluation of the specificity of pneumococcal polysaccharide enzyme-linked immunosorbent assay and effect of serum adsorption based on standard pneumococcal serogroup- or serotype-specific rabbit antisera. Clin. Vaccine Immunol. 16:1279-1284.
    • (2009) Clin. Vaccine Immunol. , vol.16 , pp. 1279-1284
    • Slotved, H.C.1    Gluttmann, C.2    Pedersen, C.D.3    Jacobsen, J.N.4    Krogfelt, K.A.5
  • 16
    • 31944441629 scopus 로고    scopus 로고
    • Suppression of non-specific binding in serological Luminex assays
    • DOI 10.1016/j.jim.2005.11.008, PII S0022175905004023
    • Waterboer, T., P. Sehr, and M. Pawlita. 2006. Suppression of non-specific binding in serological Luminex assays. J. Immunol. Methods 309:200-204. (Pubitemid 43190816)
    • (2006) Journal of Immunological Methods , vol.309 , Issue.1-2 , pp. 200-204
    • Waterboer, T.1    Sehr, P.2    Pawlita, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.