메뉴 건너뛰기




Volumn 194, Issue 5, 2010, Pages 1230-1233

Axial oblique CT to assess femoral anteversion

Author keywords

Axial oblique imaging; CT; Femoral anteversion; Femoral neck axis

Indexed keywords

ARTICLE; BODY POSITION; CADAVER; COMPUTED TOMOGRAPHY SCANNER; DIAGNOSTIC ACCURACY; FEMORAL ANTEVERSION; FEMUR; FEMUR NECK; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; MEASUREMENT; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; SIMULATION; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; WHOLE BODY CT;

EID: 77951957072     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.09.3702     Document Type: Article
Times cited : (50)

References (8)
  • 1
    • 0018248081 scopus 로고
    • Computed tomography in the measurement of femoral anteversion
    • Weiner DS, Cook AJ, Hoyt WA Jr, Oravec CE. Computed tomography in the measurement of femoral anteversion. Orthopedics 1978; 1:299-306 (Pubitemid 9165687)
    • (1978) Orthopedics , vol.1 , Issue.4 , pp. 299-306
    • Weiner, D.S.1    Cook, A.J.2    Hoyt Jr., W.A.3    Oravec, C.E.4
  • 3
    • 0031669387 scopus 로고    scopus 로고
    • A comparison of alternative methods of measuring femoral anteversion
    • DOI 10.1097/00004728-199807000-00019
    • Sugano N, Noble PC, Kamaric E. A comparison of alternative methods of measuring femoral anteversion. J Comput Assist Tomogr 1998; 22:610-614 (Pubitemid 28433796)
    • (1998) Journal of Computer Assisted Tomography , vol.22 , Issue.4 , pp. 610-614
    • Sugano, N.1    Noble, P.C.2    Kamaric, E.3
  • 4
    • 0037381342 scopus 로고    scopus 로고
    • Measurement of femoral anteversion by biplane radiography and computed tomography imaging: Comparison with an anatomic reference
    • Kuo TY, Skedros JG, Bloebaum RD. Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference. Invest Radiol 2003; 38:221-229
    • (2003) Invest Radiol , vol.38 , pp. 221-229
    • Kuo, T.Y.1    Skedros, J.G.2    Bloebaum, R.D.3
  • 6
    • 0031181365 scopus 로고    scopus 로고
    • CT measurement of anteversion in the femoral neck: The influence of femur positioning
    • Hermann KL, Egund N. CT measurement of anteversion in the femoral neck: the influence of femur positioning. Acta Radiol 1997; 38:527-532 (Pubitemid 127453106)
    • (1997) Acta Radiologica , vol.38 , Issue.4 , pp. 527-532
    • Hermann, K.L.1    Egund, N.2
  • 7
    • 0031047156 scopus 로고    scopus 로고
    • MR imaging measurement of the femoral antetorsional angle as a new technique: Comparison with CT in children and adults
    • Tomczak RJ, Guenther KP, Rieber A, Mergo P, Ros PR, Brambs HJ. MR imaging measurement of the femoral antetorsional angle as a new technique: comparison with CT in children and adults. AJR 1997; 168:791-794 (Pubitemid 27090350)
    • (1997) American Journal of Roentgenology , vol.168 , Issue.3 , pp. 791-794
    • Tomczak, R.J.1    Guenther, K.R.2    Rieber, A.3    Mergo, P.4    Ros, P.R.5    Brambs, H.-J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.