메뉴 건너뛰기




Volumn 24, Issue 4, 2010, Pages 571-575

Malfunction of the da Vinci Robotic System During Robot-Assisted Laparoscopic Prostatectomy: An International Survey

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DA VINCI ROBOTIC SYSTEM; FEMALE; HUMAN; HUMAN EXPERIMENT; INSTRUMENTAL CONDITIONING; LAPAROSCOPIC SURGERY; MALE; NORMAL HUMAN; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; ROBOT ASSISTED LAPAROSCOPIC PROSTATECTOMY; ROBOTICS; SURGICAL APPROACH; SURGICAL RISK; SURGICAL TECHNIQUE; TRAINING; TREATMENT FAILURE; TREATMENT OUTCOME; TREATMENT RESPONSE; UROLOGY;

EID: 77951949804     PISSN: 08927790     EISSN: None     Source Type: Journal    
DOI: 10.1089/end.2009.0489     Document Type: Article
Times cited : (51)

References (6)
  • 2
    • 36549075117 scopus 로고    scopus 로고
    • Da Vinci robot error and failure rates: Single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies
    • Zorn KC, Gofrit ON, Orvieto MA, et al. Da Vinci robot error and failure rates: Single institution experience on a single three-arm robot unit of more than 700 consecutive robot-assisted laparoscopic radical prostatectomies. J Endourol 2007;21:1341-1344.
    • (2007) J. Endourol. , vol.21 , pp. 1341-1344
    • Zorn, K.C.1    Gofrit, O.N.2    Orvieto, M.A.3
  • 4
    • 42149145241 scopus 로고    scopus 로고
    • Device failures associated with patient injuries during robot-assisted laparo-scopic surgeries: A comprehensive review of FDA MAUDE database
    • Andonian S, Okeke Z, Okeke DA, et al. Device failures associated with patient injuries during robot-assisted laparo-scopic surgeries: A comprehensive review of FDA MAUDE database. Can J Urol 2008;15:3912-3916.
    • (2008) Can. J. Urol. , vol.15 , pp. 3912-3916
    • Andonian, S.1    Okeke, Z.2    Okeke, D.A.3
  • 5
    • 57849130853 scopus 로고    scopus 로고
    • Malfunction of da Vinci robotic system-disassembled surgeon's console hand piece: Case report and review of the literature
    • Ham WS, Park SY, Yu HS, et al. Malfunction of da Vinci robotic system-disassembled surgeon's console hand piece: Case report and review of the literature. Urology 2009;73:209e7-8.
    • (2009) Urology , vol.73
    • Ham, W.S.1    Park, S.Y.2    Yu, H.S.3
  • 6
    • 38749083452 scopus 로고    scopus 로고
    • Intraoperative breakage of needle driver jaw during robotic-assisted laparoscopic radical prostatectomy
    • Park SY, Cho KS, Lee SW, et al. Intraoperative breakage of needle driver jaw during robotic-assisted laparoscopic radical prostatectomy. Urology 2008;71:168e5-6.
    • (2008) Urology , vol.71
    • Park, S.Y.1    Cho, K.S.2    Lee, S.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.