메뉴 건너뛰기




Volumn 125, Issue 5, 2010, Pages 451-456

Long-term stability of fibrinolytic factors stored at -80 °C

Author keywords

biobank; fibrinolysis; long term storage; plasminogen activator inhibitor 1; tissue plasminogen activator

Indexed keywords

CHROMOGENIC SUBSTRATE; FIBRINOLYTIC FACTOR; PLASMINOGEN ACTIVATOR INHIBITOR 1; PLASMINOGEN ACTIVATOR INHIBITOR 1 TISSUE PLASMINOGEN ACTIVATOR COMPLEX; REAGENT; TISSUE PLASMINOGEN ACTIVATOR; UNCLASSIFIED DRUG;

EID: 77951879470     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2009.12.007     Document Type: Article
Times cited : (10)

References (11)
  • 1
    • 0035652393 scopus 로고    scopus 로고
    • Longitudinal stability of coagulation, fibrinolysis, and inflammation factors in stored plasma samples
    • Lewis M.R., Callas P.W., Jenny N.S., and Tracy R.P. Longitudinal stability of coagulation, fibrinolysis, and inflammation factors in stored plasma samples. Thromb Haemost 86 6 (2001 Dec) 1495-1500
    • (2001) Thromb Haemost , vol.86 , Issue.6 , pp. 1495-1500
    • Lewis, M.R.1    Callas, P.W.2    Jenny, N.S.3    Tracy, R.P.4
  • 2
    • 0345879080 scopus 로고    scopus 로고
    • el Attar I, Aboul Enein A, Gaafar T, et al. Effect of cold storage on the haemostatic cascade systems
    • Omran S., Hallouda M., and Essawi F. el Attar I, Aboul Enein A, Gaafar T, et al. Effect of cold storage on the haemostatic cascade systems. Transfus Sci. 17 3 (1996 Sep) 407-414
    • (1996) Transfus Sci. , vol.17 , Issue.3 , pp. 407-414
    • Omran, S.1    Hallouda, M.2    Essawi, F.3
  • 4
    • 64649093982 scopus 로고    scopus 로고
    • Effect of freezing method and storage at -20 degrees C and -70 degrees C on prothrombin time, aPTT and plasma fibrinogen levels
    • Alesci S., Borggrefe M., and Dempfle C.E. Effect of freezing method and storage at -20 degrees C and -70 degrees C on prothrombin time, aPTT and plasma fibrinogen levels. Thromb Res 124 1 (2009) 121-126
    • (2009) Thromb Res , vol.124 , Issue.1 , pp. 121-126
    • Alesci, S.1    Borggrefe, M.2    Dempfle, C.E.3
  • 5
    • 2442547553 scopus 로고    scopus 로고
    • Cardiovascular disease and diabetes in the Northern Sweden Health and Disease Study Cohort - evaluation of risk factors and their interactions
    • Hallmans G., Ågren Å., Johansson G., Stegmayr B., Jansson J., Lindahl B., et al. Cardiovascular disease and diabetes in the Northern Sweden Health and Disease Study Cohort - evaluation of risk factors and their interactions. Scand J Public Health 31 Suppl 61 (2003) 18-24
    • (2003) Scand J Public Health , vol.31 , Issue.SUPPL. 61 , pp. 18-24
    • Hallmans, G.1    Ågren, Å.2    Johansson, G.3    Stegmayr, B.4    Jansson, J.5    Lindahl, B.6
  • 6
    • 20144385005 scopus 로고    scopus 로고
    • Comparison of soluble thrombomodulin, von Willebrand factor, tPA/PAI-1 complex, and high-sensitivity CRP concentrations in serum, EDTA plasma, citrated plasma, and acidified citrated plasma (Stabilyte) stored at -70 degrees C for 8-11 years
    • Nilsson T.K., Boman K., Jansson J.H., Thøgersen A.M., Berggren M., Broberg A., et al. Comparison of soluble thrombomodulin, von Willebrand factor, tPA/PAI-1 complex, and high-sensitivity CRP concentrations in serum, EDTA plasma, citrated plasma, and acidified citrated plasma (Stabilyte) stored at -70 degrees C for 8-11 years. Thromb Res 116 3 (2005) 249-254
    • (2005) Thromb Res , vol.116 , Issue.3 , pp. 249-254
    • Nilsson, T.K.1    Boman, K.2    Jansson, J.H.3    Thøgersen, A.M.4    Berggren, M.5    Broberg, A.6
  • 7
    • 0027383217 scopus 로고
    • Influence of gender, age and sampling time on plasma fibrinolytic variables and fibrinogen
    • Eliasson M., Evrin P.E., Lundblad D., Asplund K., and Rånby M. Influence of gender, age and sampling time on plasma fibrinolytic variables and fibrinogen. Fibrinolysis 7 5 (1993) 316-323
    • (1993) Fibrinolysis , vol.7 , Issue.5 , pp. 316-323
    • Eliasson, M.1    Evrin, P.E.2    Lundblad, D.3    Asplund, K.4    Rånby, M.5
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 8476 (Feb 8 1986) 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 9
    • 0019596036 scopus 로고
    • Evaluation of method-comparison data
    • Eksborg S. Evaluation of method-comparison data. Clin Chem 27 7 (Jul 1981) 1311-1312
    • (1981) Clin Chem , vol.27 , Issue.7 , pp. 1311-1312
    • Eksborg, S.1
  • 10
    • 0022894665 scopus 로고
    • Age dependence of tissue plasminogen activator concentrations in plasma, as studied by an improved enzyme-linked immunosorbent assay
    • Rånby M., Bergsdorf N., Nilsson T., Mellbring G., Winblad B., and Bucht G. Age dependence of tissue plasminogen activator concentrations in plasma, as studied by an improved enzyme-linked immunosorbent assay. Clin Chem 32 12 (1986 Dec) 2160-2165
    • (1986) Clin Chem , vol.32 , Issue.12 , pp. 2160-2165
    • Rånby, M.1    Bergsdorf, N.2    Nilsson, T.3    Mellbring, G.4    Winblad, B.5    Bucht, G.6
  • 11
    • 0029963427 scopus 로고    scopus 로고
    • Update: blood collection and handling procedures for assessment of plasminogen activators and inhibitors (Leiden Fibrinolysis Workshop)
    • Kluft C., and Meijer P. Update: blood collection and handling procedures for assessment of plasminogen activators and inhibitors (Leiden Fibrinolysis Workshop). Fibrinolysis 1996 10 (1996) 171-179
    • (1996) Fibrinolysis , vol.1996 , Issue.10 , pp. 171-179
    • Kluft, C.1    Meijer, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.