메뉴 건너뛰기




Volumn 92, Issue 5, 2010, Pages 661-667

Failure of metal radial head replacement

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; AGED; ARTHROPLASTY; ARTICLE; CLINICAL ARTICLE; FEMALE; FRACTURE FIXATION; HUMAN; JOINT INSTABILITY; MALE; METAL IMPLANTATION; PRIORITY JOURNAL; PROSTHESIS LOOSENING; RADIUS HEAD FRACTURE; TREATMENT FAILURE;

EID: 77951858381     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.92B5.23067     Document Type: Article
Times cited : (117)

References (32)
  • 1
    • 0026331754 scopus 로고
    • Valgus stability of the elbow: A definition of primary and secondary constraints
    • Morrey BF, Tanaka S, An KN. Valgus stability of the elbow: a definition of primary and secondary constraints. Clin Orthop 1991;265:187-195
    • (1991) Clin Orthop , vol.265 , pp. 187-195
    • Morrey, B.F.1    Tanaka, S.2    An, K.N.3
  • 3
    • 33644804193 scopus 로고    scopus 로고
    • Associated injuries complicating radial head fractures: A demographic study
    • van Riet RP, Morrey BF, O'Driscoll SW, Van Glabbeek F. Associated injuries complicating radial head fractures: a demographic study. Clin Orthop 2005;441:351-355
    • (2005) Clin Orthop , vol.441 , pp. 351-355
    • Van Riet, R.P.1    Morrey, B.F.2    O'Driscoll, S.W.3    Van Glabbeek, F.4
  • 5
    • 41149138084 scopus 로고    scopus 로고
    • Documentation of associated injuries occurring with radial head fracture
    • van Riet RP, Morrey BF. Documentation of associated injuries occurring with radial head fracture. Clin Orthop 2008;466:130-134
    • (2008) Clin Orthop , vol.466 , pp. 130-134
    • Van Riet, R.P.1    Morrey, B.F.2
  • 6
    • 0036799350 scopus 로고    scopus 로고
    • Open reduction and internal fixation of fractures of the radial head
    • Ring D, Quintero J, Jupiter JB. Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg [Am] 2002;84-A:1811-1815
    • (2002) J Bone Joint Surg [Am] , vol.84 A , pp. 1811-1815
    • Ring, D.1    Quintero, J.2    Jupiter, J.B.3
  • 7
    • 59449104367 scopus 로고    scopus 로고
    • A comparative study of internal fixation and prosthesis replacement for radial head fractures of Mason type III
    • Ruan HJ, Fan CY, Liu JJ, Zeng BF. A comparative study of internal fixation and prosthesis replacement for radial head fractures of Mason type III. Int Orthop 2007;33:249-253
    • (2007) Int Orthop , vol.33 , pp. 249-253
    • Ruan, H.J.1    Fan, C.Y.2    Liu, J.J.3    Zeng, B.F.4
  • 9
    • 33644857426 scopus 로고    scopus 로고
    • Treatment of sequelae of radial head fractures with a bipolar radial head prosthesis: Good outcome after 1-4 years follow-up in 11 patients
    • Brinkman JM, Rahusen FT, de Vos MJ, Eygendaal D. Treatment of sequelae of radial head fractures with a bipolar radial head prosthesis: good outcome after 1-4 years follow-up in 11 patients. Acta Orthop 2005;76:867-872
    • (2005) Acta Orthop , vol.76 , pp. 867-872
    • Brinkman, J.M.1    Rahusen, F.T.2    De Vos, M.J.3    Eygendaal, D.4
  • 10
    • 24944518762 scopus 로고    scopus 로고
    • Recent fractures of the radial head associated with elbow instability treated with floating Judet prosthesis
    • in French
    • Gabrion A, Havet E, Bellot F, et al. Recent fractures of the radial head associated with elbow instability treated with floating Judet prosthesis. Rev Chir Orthop Reparatrice Appar Mot 2005;91:407-414 (in French).
    • (2005) Rev Chir Orthop Reparatrice Appar Mot , vol.91 , pp. 407-414
    • Gabrion, A.1    Havet, E.2    Bellot, F.3
  • 11
    • 0033748108 scopus 로고    scopus 로고
    • The floating radial head prosthesis for comminuted radial head fractures: A multicentre study
    • Smets S, Govaers K, Jansen N, et al. The floating radial head prosthesis for comminuted radial head fractures: a multicentre study. Acta Orthop Belg 2000;66:353-358
    • (2000) Acta Orthop Belg , vol.66 , pp. 353-358
    • Smets, S.1    Govaers, K.2    Jansen, N.3
  • 12
    • 0942301372 scopus 로고    scopus 로고
    • Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization
    • Ashwood N, Bain GI, Unni R. Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. J Bone Joint Surg [Am] 2004;86-A:274-280
    • (2004) J Bone Joint Surg [Am] , vol.86 A , pp. 274-280
    • Ashwood, N.1    Bain, G.I.2    Unni, R.3
  • 13
    • 33745652657 scopus 로고    scopus 로고
    • Comminuted fractures of the radial head treated by the Judet floating radial head prosthesis
    • Dotzis A, Cochu G, Mabit C, Charissoux JL, Arnaud JP. Comminuted fractures of the radial head treated by the Judet floating radial head prosthesis. J Bone Joint Surg [Br] 2006;88-B:760-764
    • (2006) J Bone Joint Surg [Br] , vol.88 B , pp. 760-764
    • Dotzis, A.1    Cochu, G.2    Mabit, C.3    Charissoux, J.L.4    Arnaud, J.P.5
  • 14
    • 0035153597 scopus 로고    scopus 로고
    • The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: A long-term review
    • Harrington IJ, Sekyi-Otu A, Barrington TW, Evans DC, Tuli V. The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review. J Trauma 2001;50:46-52.
    • (2001) J Trauma , vol.50 , pp. 46-52
    • Harrington, I.J.1    Sekyi-Otu, A.2    Barrington, T.W.3    Evans, D.C.4    Tuli, V.5
  • 15
    • 34147124354 scopus 로고    scopus 로고
    • Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: A cadaver study
    • van Riet RP, van Glabbeek F, de Weerdt W, Oemar J, Bortier H. Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: a cadaver study. J Bone Joint Surg [Br] 2007;89- B:413-416
    • (2007) J Bone Joint Surg [Br] , vol.89 B , pp. 413-416
    • Van Riet, R.P.1    Van Glabbeek, F.2    De Weerdt, W.3    Oemar, J.4    Bortier, H.5
  • 16
    • 34247618730 scopus 로고    scopus 로고
    • Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing
    • Rowland AS, Athwal GS, MacDermid JC, King GJ. Lateral ulnohumeral joint space widening is not diagnostic of radial head arthroplasty overstuffing. J Hand Surg [Am] 2007;32:637-641
    • (2007) J Hand Surg [Am] , vol.32 , pp. 637-641
    • Rowland, A.S.1    Athwal, G.S.2    MacDermid, J.C.3    King, G.J.4
  • 17
    • 40649098436 scopus 로고    scopus 로고
    • Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis
    • Shors HC, Gannon C, Miller MC, Schmidt CC, Baratz ME. Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg [Am] 2008;33:335-339
    • (2008) J Hand Surg [Am] , vol.33 , pp. 335-339
    • Shors, H.C.1    Gannon, C.2    Miller, M.C.3    Schmidt, C.C.4    Baratz, M.E.5
  • 18
    • 67651150030 scopus 로고    scopus 로고
    • Determination of correct implant size in radial head arthroplasty to avoid overlengthening
    • Frank SG, Grewal R, Johnson J, et al. Determination of correct implant size in radial head arthroplasty to avoid overlengthening. J Bone Joint Surg [Am] 2009;91-A:1738-1746
    • (2009) J Bone Joint Surg [Am] , vol.91 A , pp. 1738-1746
    • Frank, S.G.1    Grewal, R.2    Johnson, J.3
  • 19
    • 0022538122 scopus 로고
    • Results of delayed excision of the radial head after fracture
    • Broberg MA, Morrey BF. Results of delayed excision of the radial head after fracture. J Bone Joint Surg [Am] 1986;68-A:669-674
    • (1986) J Bone Joint Surg [Am] , vol.68 A , pp. 669-674
    • Broberg, M.A.1    Morrey, B.F.2
  • 20
    • 0019455156 scopus 로고
    • A biomechanical study of normal functional elbow motion
    • Morrey BF, Askew LJ, Chao EY. A biomechanical study of normal functional elbow motion. J Bone Joint Surg [Am] 1981;63-A:872-877
    • (1981) J Bone Joint Surg [Am] , vol.63 A , pp. 872-877
    • Morrey, B.F.1    Askew, L.J.2    Chao, E.Y.3
  • 22
    • 33745431846 scopus 로고    scopus 로고
    • Heterotopic ossification causing proximal radioulnar synostosis after insertion of a radial head prosthesis
    • Bimmel R, van Riet RP, Sys J. Heterotopic ossification causing proximal radioulnar synostosis after insertion of a radial head prosthesis. J Hand Surg [Br] 2006;31:383-384
    • (2006) J Hand Surg [Br] , vol.31 , pp. 383-384
    • Bimmel, R.1    Van Riet, R.P.2    Sys, J.3
  • 23
    • 55249089226 scopus 로고    scopus 로고
    • Complete dissociation of a bipolar radial head prosthesis: A case report
    • Herald J, O'Driscoll S. Complete dissociation of a bipolar radial head prosthesis: a case report. J Shoulder Elbow Surg 2008;17:e22-3.
    • (2008) J Shoulder Elbow Surg , vol.17
    • Herald, J.1    O'Driscoll, S.2
  • 24
    • 34248166404 scopus 로고    scopus 로고
    • Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability
    • Doornberg JN, Parisien R, van Duijn PJ, Ring D. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. J Bone Joint Surg [Am] 2007;89-A:1075-1080
    • (2007) J Bone Joint Surg [Am] , vol.89 A , pp. 1075-1080
    • Doornberg, J.N.1    Parisien, R.2    Van Duijn, P.J.3    Ring, D.4
  • 25
    • 33645237503 scopus 로고    scopus 로고
    • Radial head prosthesis after fracture of radial head with associated elbow instability
    • Wretenberg P, Ericson A, Stark A. Radial head prosthesis after fracture of radial head with associated elbow instability. Arch Orthop Trauma Surg 2006;126:145-149
    • (2006) Arch Orthop Trauma Surg , vol.126 , pp. 145-149
    • Wretenberg, P.1    Ericson, A.2    Stark, A.3
  • 26
    • 36048989342 scopus 로고    scopus 로고
    • Midterm results with a bipolar radial head prosthesis: Radiographic evidence of loosening at the bone-cement interface
    • Popovic N, Lemaire R, Georis P, Gillet P. Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg [Am] 2007;89-A:2469-2476
    • (2007) J Bone Joint Surg [Am] , vol.89 A , pp. 2469-2476
    • Popovic, N.1    Lemaire, R.2    Georis, P.3    Gillet, P.4
  • 27
    • 40149093071 scopus 로고    scopus 로고
    • Short-term to medium-term outcomes of cemented Vitallium radial head prostheses after early excision for radial head fractures
    • Lim YJ, Chan BK. Short-term to medium-term outcomes of cemented Vitallium radial head prostheses after early excision for radial head fractures. J Shoulder Elbow Surg 2008;17:307-312
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 307-312
    • Lim, Y.J.1    Chan, B.K.2
  • 29
    • 10344234202 scopus 로고    scopus 로고
    • Detrimental effects of over-stuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow
    • Van Glabbeek F, van Riet RP, Baumfield JA, et al. Detrimental effects of over-stuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg [Am] 2004;86-A:2629-2635
    • (2004) J Bone Joint Surg [Am] , vol.86 A , pp. 2629-2635
    • Van Glabbeek, F.1    Van Riet, R.P.2    Baumfield, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.