메뉴 건너뛰기




Volumn 7568, Issue , 2010, Pages

Label-free single cell analysis with a chip-based impedance flow cytometer

Author keywords

Cytomics; Impedance characterization; Label free; Microfluidics; Single cell analysis

Indexed keywords

CELL ANALYSIS; CELL MEMBRANE CAPACITANCE; CELL VOLUME; CELLULAR PHENOTYPES; CYTOMICS; CYTOPLASMIC CONDUCTIVITY; CYTOTOXIC AGENTS; DEAD CELLS; FLOW-CYTOMETER; IMPEDANCE ANALYSIS; IMPEDANCE CHARACTERIZATION; IN-CELL; LABEL FREE; MCF-7 CELLS; MEMBRANE POTENTIALS; PHYSIOLOGICAL CONDITION; PHYSIOLOGICAL STATE; POTENTIAL APPLICATIONS; SIGNAL ACQUISITIONS; SINGLE CELLS; SINGLECELL ANALYSIS;

EID: 77951828872     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.840865     Document Type: Conference Paper
Times cited : (9)

References (43)
  • 3
    • 43049129701 scopus 로고    scopus 로고
    • Raman spectroscopy comes to flow cytometry
    • J.H. Jett, "Raman spectroscopy comes to flow cytometry" Cytometry A 73, 109-110 (2008).
    • (2008) Cytometry A , vol.73 , pp. 109-110
    • Jett, J.H.1
  • 4
    • 71049146830 scopus 로고    scopus 로고
    • Differentiation of alloreactive versus CD3/CD28 stimulated T-lymphocytes using Raman spectroscopy: A greater specificity for noninvasive acute renal allograft rejection detection
    • K.L. Brown, O.Y. Palyvoda, J.S. Thakur, S.L. Nehlsen-Cannarella, O.R. Fagoaga, S.A. Gruber, G.W. Auner, "Differentiation of alloreactive versus CD3/CD28 stimulated T-lymphocytes using Raman spectroscopy: a greater specificity for noninvasive acute renal allograft rejection detection" Cytometry A 75, 917-923 (2009).
    • (2009) Cytometry A , vol.75 , pp. 917-923
    • Brown, K.L.1    Palyvoda, O.Y.2    Thakur, J.S.3    Nehlsen-Cannarella, S.L.4    Fagoaga, O.R.5    Gruber, S.A.6    Auner, G.W.7
  • 6
    • 60849133023 scopus 로고    scopus 로고
    • Vibrational spectroscopy - A powerful tool for the rapid identification of microbial cells at the single-cell level
    • M. Harz, P. Rösch, J. Popp, "Vibrational spectroscopy - a powerful tool for the rapid identification of microbial cells at the single-cell level" Cytometry A 75, 104-113 (2009).
    • (2009) Cytometry A , vol.75 , pp. 104-113
    • Harz, M.1    Rösch, P.2    Popp, J.3
  • 7
    • 56749132126 scopus 로고    scopus 로고
    • Rapid and label-free classification of human glioma cells by infrared spectroscopic imaging
    • G. Steiner, S. Küchler, A. Hermann, E. Koch, R. Salzer, G. Schackert, M. Kirsch, "Rapid and label-free classification of human glioma cells by infrared spectroscopic imaging" Cytometry A 73A, 1158-1164 (2008).
    • (2008) Cytometry A , vol.73 A , pp. 1158-1164
    • Steiner, G.1    Küchler, S.2    Hermann, A.3    Koch, E.4    Salzer, R.5    Schackert, G.6    Kirsch, M.7
  • 8
    • 42049087176 scopus 로고    scopus 로고
    • Automated classification of bacterial particles in flow by multiangle scatter measurement and support vector machine classifier
    • B. Rajwa, M. Venkatapathi, K. Ragheb, P.P. Banada, E.D. Hirleman, T. Lary, J.P. Robinson, "Automated classification of bacterial particles in flow by multiangle scatter measurement and support vector machine classifier" Cytometry A 73, 369-379 (2008).
    • (2008) Cytometry A , vol.73 , pp. 369-379
    • Rajwa, B.1    Venkatapathi, M.2    Ragheb, K.3    Banada, P.P.4    Hirleman, E.D.5    Lary, T.6    Robinson, J.P.7
  • 9
    • 53049088101 scopus 로고    scopus 로고
    • In vivo multispectral, multiparameter, photoacoustic lymph flow cytometry with natural cell focusing, label-free detection and multicolor nanoparticle probes
    • E. Galanzha, E. Shashkov, V. Tuchin, V. Zharov, "In vivo multispectral, multiparameter, photoacoustic lymph flow cytometry with natural cell focusing, label-free detection and multicolor nanoparticle probes" Cytom Part A 73, 884-894 (2008).
    • (2008) Cytom Part A , vol.73 , pp. 884-894
    • Galanzha, E.1    Shashkov, E.2    Tuchin, V.3    Zharov, V.4
  • 10
    • 0141989814 scopus 로고    scopus 로고
    • Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing
    • S. Gawad, L. Schild, P. Renaud, "Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing" Lab Chip 1, 76-82 (2001).
    • (2001) Lab Chip , vol.1 , pp. 76-82
    • Gawad, S.1    Schild, L.2    Renaud, P.3
  • 11
    • 0001194259 scopus 로고
    • High speed automatic blood cell counter and cell size analyzer
    • W.H. Coulter, "High speed automatic blood cell counter and cell size analyzer" Proc natl Electron Conf 12, 1034-1042 (1956).
    • (1956) Proc Natl Electron Conf , vol.12 , pp. 1034-1042
    • Coulter, W.H.1
  • 12
    • 0018312058 scopus 로고
    • Flow-System Measurement of Cell Impedance Properties
    • R.A. Hoffman, W.B. Britt, "Flow-System Measurement of Cell Impedance Properties" J Histochem Cytochem 27, 234-240 (1979).
    • (1979) J Histochem Cytochem , vol.27 , pp. 234-240
    • Hoffman, R.A.1    Britt, W.B.2
  • 13
    • 0019453628 scopus 로고
    • Flow Cytometric Electronic Direct Current Volume and Radiofrequency Impedance Measurements of Single Cells and Particles
    • R.A. Hoffman, T.S. Johnson, W.B. Britt, "Flow Cytometric Electronic Direct Current Volume and Radiofrequency Impedance Measurements of Single Cells and Particles" Cytometry 1, 377-384 (1981).
    • (1981) Cytometry , vol.1 , pp. 377-384
    • Hoffman, R.A.1    Johnson, T.S.2    Britt, W.B.3
  • 14
    • 34248163500 scopus 로고    scopus 로고
    • Development and validation of flowcytometric measurement for parasitemia in cultures of P. falciparum vitally stained withYOYO-1
    • Q. Li, L. Gerena, L. Xie, J. Zhang, D. Kyle, W. Milhous, "Development and validation of flowcytometric measurement for parasitemia in cultures of P. falciparum vitally stained withYOYO-1" Cytometry part A 71A, 297-307 (2007).
    • (2007) Cytometry Part A , vol.71 A , pp. 297-307
    • Li, Q.1    Gerena, L.2    Xie, L.3    Zhang, J.4    Kyle, D.5    Milhous, W.6
  • 16
    • 65249105570 scopus 로고    scopus 로고
    • Dynamic monitoring of changes in endothelial cell-substrate adhesiveness during leukocyte adhesion by microelectrical impedance assay
    • Y. Ge, T. Deng, X. Zheng, "Dynamic monitoring of changes in endothelial cell-substrate adhesiveness during leukocyte adhesion by microelectrical impedance assay" Acta Biochim Biophys Sin (Shanghai) 41, 256-262 (2009).
    • (2009) Acta Biochim Biophys Sin (Shanghai) , vol.41 , pp. 256-262
    • Ge, Y.1    Deng, T.2    Zheng, X.3
  • 17
    • 42949124474 scopus 로고    scopus 로고
    • The application of cell-based label-free technology in drug discovery
    • Review
    • B. Xi, N. Yu, X. Wang, X. Xu, Y.A. Abassi, "The application of cell-based label-free technology in drug discovery" Biotechnol J. 3, 484-495 Review (2008).
    • (2008) Biotechnol J. , vol.3 , pp. 484-495
    • Xi, B.1    Yu, N.2    Wang, X.3    Xu, X.4    Abassi, Y.A.5
  • 18
    • 3142726971 scopus 로고    scopus 로고
    • Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations
    • S. Gawad, K.C. Cheung, U. Seger, A. Bertsch, P. Renaud, "Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations" Lab Chip 4, 241-251 (2004).
    • (2004) Lab Chip , vol.4 , pp. 241-251
    • Gawad, S.1    Cheung, K.C.2    Seger, U.3    Bertsch, A.4    Renaud, P.5
  • 19
    • 19444377196 scopus 로고    scopus 로고
    • Impedance spectroscopy flow cytometry: On-chip label-free cell differentiation
    • K. Cheung, S. Gawad, P.Renaud, "Impedance spectroscopy flow cytometry: On-chip label-free cell differentiation" Cytom Part A 65A, 124-132 (2005).
    • (2005) Cytom Part A , vol.65 A , pp. 124-132
    • Cheung, K.1    Gawad, S.2    Renaud, P.3
  • 20
    • 34249307247 scopus 로고    scopus 로고
    • Label-free detection of Babesia bovis infected red blood cells using impedance spectroscopy on a microfabricated flow cytometer
    • C. Küttel, E. Nascimento, N. Demierre, T. Silva, T. Braschler, P. Renaud, A.G. Oliva, "Label-free detection of Babesia bovis infected red blood cells using impedance spectroscopy on a microfabricated flow cytometer" Acta Trop 102, 63-68 (2007).
    • (2007) Acta Trop , vol.102 , pp. 63-68
    • Küttel, C.1    Nascimento, E.2    Demierre, N.3    Silva, T.4    Braschler, T.5    Renaud, P.6    Oliva, A.G.7
  • 21
    • 34547111796 scopus 로고    scopus 로고
    • Bead-based immunoassays using a micro-chip flow cytometer
    • D. Holmes, J.K. She, P.L. Roach, H. Morgan, "Bead-based immunoassays using a micro-chip flow cytometer" Lab Chip 7, 1048-1056 (2007).
    • (2007) Lab Chip , vol.7 , pp. 1048-1056
    • Holmes, D.1    She, J.K.2    Roach, P.L.3    Morgan, H.4
  • 22
    • 34249987410 scopus 로고    scopus 로고
    • Impedance spectroscopy using maximum length sequences: Application to single cell analysis
    • S. Gawad, T. Sun, N.G. Green, H. Morgan, "Impedance spectroscopy using maximum length sequences: Application to single cell analysis" Rev Sci Instrum 78, 054301 (2007).
    • (2007) Rev Sci Instrum , vol.78 , pp. 054301
    • Gawad, S.1    Sun, T.2    Green, N.G.3    Morgan, H.4
  • 25
    • 64449085887 scopus 로고    scopus 로고
    • A microelectrode-based sensor for label-free in vitro detection of ischemic effects on cardiomyocytes
    • D. Krinke, H. Jahnke, O. Pänke, A. Robitzki "A microelectrode-based sensor for label-free in vitro detection of ischemic effects on cardiomyocytes" Biosens Bioelectron 24, 2798-2803 (2009).
    • (2009) Biosens Bioelectron , vol.24 , pp. 2798-2803
    • Krinke, D.1    Jahnke, H.2    Pänke, O.3    Robitzki, A.4
  • 26
    • 65649128544 scopus 로고    scopus 로고
    • An impedimetric microelectrode-based array sensor for label-free detection of tau hyperphosphorylation in human cells
    • H.G. Jahnke, A. Rothermel, I. Sternberger, T.G. Mack, R.G. Kurz, O. Pänke, F. Striggow, A.A. Robitzki, "An impedimetric microelectrode-based array sensor for label-free detection of tau hyperphosphorylation in human cells" Lab Chip 9, 1422-1428 (2009).
    • (2009) Lab Chip , vol.9 , pp. 1422-1428
    • Jahnke, H.G.1    Rothermel, A.2    Sternberger, I.3    Mack, T.G.4    Kurz, R.G.5    Pänke, O.6    Striggow, F.7    Robitzki, A.A.8
  • 27
    • 34047237922 scopus 로고    scopus 로고
    • Real-time measurement of PMA-induced cellular alterations by microelectrode array-based impedance spectroscopy
    • A. Rothermel, M. Nieber, J. Müller, P. Wolf, M. Schmidt, A.A. Robitzki, "Real-time measurement of PMA-induced cellular alterations by microelectrode array-based impedance spectroscopy" Biotechniques 41, 445-450 (2006).
    • (2006) Biotechniques , vol.41 , pp. 445-450
    • Rothermel, A.1    Nieber, M.2    Müller, J.3    Wolf, P.4    Schmidt, M.5    Robitzki, A.A.6
  • 28
    • 48349098172 scopus 로고    scopus 로고
    • Microelectrode chip based real time monitoring of vital MCF-7 mamma carcinoma cells by impedance spectroscopy
    • P. Wolf, A. Rothermel, A.G. Beck-Sickinger, A.A. Robitzki, "Microelectrode chip based real time monitoring of vital MCF-7 mamma carcinoma cells by impedance spectroscopy" Biosens Bioelectron 24, 253-259 (2008).
    • (2008) Biosens Bioelectron , vol.24 , pp. 253-259
    • Wolf, P.1    Rothermel, A.2    Beck-Sickinger, A.G.3    Robitzki, A.A.4
  • 30
    • 36249015335 scopus 로고    scopus 로고
    • Discrimination and analysis of phytoplankton using a microfluidic cytometer
    • G. Benazzi, D. Holmes, T. Sun, M.C. Mowlem, H. Morgan, "Discrimination and analysis of phytoplankton using a microfluidic cytometer" IET Nanobiotechnol 1, 94-101 (2007).
    • (2007) IET Nanobiotechnol , vol.1 , pp. 94-101
    • Benazzi, G.1    Holmes, D.2    Sun, T.3    Mowlem, M.C.4    Morgan, H.5
  • 32
    • 53049110086 scopus 로고    scopus 로고
    • Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedance volume analyzer
    • B. Rappaz, A. Barbul, Y. Emery, R. Korenstein, C. Depeursinge, P. Magistretti, P. Marquet, "Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedance volume analyzer" Cytom Part A 73, 895-903 (2008).
    • (2008) Cytom Part A , vol.73 , pp. 895-903
    • Rappaz, B.1    Barbul, A.2    Emery, Y.3    Korenstein, R.4    Depeursinge, C.5    Magistretti, P.6    Marquet, P.7
  • 33
    • 13244273521 scopus 로고    scopus 로고
    • Multiparametric characterizationby flow cytometry of flow-sorted subpopulations of a human hepatoma cell line useful for drug research
    • J.E. O'Connor, A. Martínez, J.V. Castell, M.J. Gómez-Lechón, "Multiparametric characterizationby flow cytometry of flow-sorted subpopulations of a human hepatoma cell line useful for drug research" Cytom Part A 63, 48-58 (2005).
    • (2005) Cytom Part A , vol.63 , pp. 48-58
    • O'Connor, J.E.1    Martínez, A.2    Castell, J.V.3    Gómez-Lechón, M.J.4
  • 35
    • 67651064699 scopus 로고    scopus 로고
    • Cytomics and regenerative medicine
    • J. Bocsi, A. Tárnok, "Cytomics and regenerative medicine", Cytometry A 75, 707-708 (2009).
    • (2009) Cytometry A , vol.75 , pp. 707-708
    • Bocsi, J.1    Tárnok, A.2
  • 36
    • 74849131381 scopus 로고    scopus 로고
    • When senescence masquerades as DNA damage: Is DNA replication stress the culprit?
    • Z. Darzynkiewicz, "When senescence masquerades as DNA damage: is DNA replication stress the culprit?" Cell Cycle 8, 3810-3811 (2009).
    • (2009) Cell Cycle , vol.8 , pp. 3810-3811
    • Darzynkiewicz, Z.1
  • 37
    • 42949105951 scopus 로고    scopus 로고
    • How many events is enough? Are you positive?
    • M. Roederer, "How many events is enough? Are you positive?" Cytometry Part A 73, 384-385 (2008).
    • (2008) Cytometry Part A , vol.73 , pp. 384-385
    • Roederer, M.1
  • 38
    • 33845451529 scopus 로고    scopus 로고
    • Resources for integrative systems biology: From data through databases to networks and dynamic system models
    • A. Ng, B. Bursteinas, Q. Gao, E. Mollison, M. Zvelebil, "Resources for integrative systems biology: from data through databases to networks and dynamic system models" Brief Bioinform 7, 318-330 (2006).
    • (2006) Brief Bioinform , vol.7 , pp. 318-330
    • Ng, A.1    Bursteinas, B.2    Gao, Q.3    Mollison, E.4    Zvelebil, M.5
  • 39
    • 61649088149 scopus 로고    scopus 로고
    • Cytomics and cellular informatics-coping with asymmetry and heterogeneity in biological systems
    • P.J. Smith, I.A. Khan, R.J. Errington, "Cytomics and cellular informatics-coping with asymmetry and heterogeneity in biological systems" Drug Discov Today 14, 271-277 (2009).
    • (2009) Drug Discov Today , vol.14 , pp. 271-277
    • Smith, P.J.1    Khan, I.A.2    Errington, R.J.3
  • 41
    • 68849093360 scopus 로고    scopus 로고
    • Hierarchical clustering of monoclonal antibody reactivity patterns in nonhuman species
    • J.P. Pratt, Q. Zeng, D. Ravnic, H. Huss, J. Rawn, S.J. Mentzer, "Hierarchical clustering of monoclonal antibody reactivity patterns in nonhuman species" Cytometry A 75, 734-742 (2009).
    • (2009) Cytometry A , vol.75 , pp. 734-742
    • Pratt, J.P.1    Zeng, Q.2    Ravnic, D.3    Huss, H.4    Rawn, J.5    Mentzer, S.J.6
  • 42
    • 42949083636 scopus 로고    scopus 로고
    • Mixture modeling approach to flow cytometry data
    • M.J. Boedigheimer, J. Ferbas, "Mixture modeling approach to flow cytometry data" Cytometry A 73, 421-429 (2008).
    • (2008) Cytometry A , vol.73 , pp. 421-429
    • Boedigheimer, M.J.1    Ferbas, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.