메뉴 건너뛰기




Volumn 55, Issue 10, 2010, Pages 2917-2939

Optimal relaxation parameters of DRAMA (dynamic RAMLA) aiming at one-pass image reconstruction for 3D-PET

Author keywords

[No Author keywords available]

Indexed keywords

BLOCK-ITERATIVE ALGORITHMS; COMPARATIVE STUDIES; DESIGN PARAMETERS; EMISSION TOMOGRAPHY; FAST CONVERGENCE; NOISE PROPAGATION; ONE-PASS; OPERATING CONDITION; OPTIMAL RELAXATION PARAMETER; PET SCANNER; RECONSTRUCTED IMAGE; RELAXATION PARAMETER; ROW-ACTION MAXIMUM LIKELIHOOD ALGORITHMS; SIMULATION STUDIES; THREE-DIMENSIONAL (3-D) RECONSTRUCTION;

EID: 77951771096     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/10/009     Document Type: Article
Times cited : (34)

References (14)
  • 1
    • 0030270511 scopus 로고    scopus 로고
    • A row-action alternative to the em algorithm for maximizing likelihoods in emission tomography
    • Browne J and De Pierro A 1996 A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography IEEE Trans. Med. Imaging 15 687-99
    • (1996) IEEE Trans. Med. Imaging , vol.15 , pp. 687-699
    • Browne, J.1    De Pierro, A.2
  • 2
    • 23844530411 scopus 로고    scopus 로고
    • Performance evaluation of relaxed block-iterative algorithms for 3D PET reconstruction
    • Fukano A, Nakayama T and Kudo H 2004 Performance evaluation of relaxed block-iterative algorithms for 3D PET reconstruction IEEE Medical Imaging Conf. Record 2004 (M4-1) pp 2830-4
    • (2004) IEEE Medical Imaging Conf. Record 2004 (M4-1) , pp. 2830-2834
    • Fukano, A.1    Nakayama, T.2    Kudo, H.3
  • 3
    • 28544451601 scopus 로고    scopus 로고
    • Convergence results for scaled gradient algorithms in positron emission tomography
    • Neto E S H and De Piero A R 2005 Convergence results for scaled gradient algorithms in positron emission tomography Inverse Problems 21 1905-14
    • (2005) Inverse Problems , vol.21 , pp. 1905-1914
    • Neto, E.S.H.1    De Piero, A.R.2
  • 4
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H M and Larkin R S 1994 Accelerated image reconstruction using ordered subsets of projection data IEEE Trans. Med. Imaging 13 601-9
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 5
    • 0027934281 scopus 로고
    • Accelerated em reconstruction in total-body PET: Potential for improving tumour detectability
    • Meikle S R, Hutton B F, Bailey D L, Hooper P K and Fulham M J 1994 Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability Phys. Med. Biol. 39 1689-704
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1689-1704
    • Meikle, S.R.1    Hutton, B.F.2    Bailey, D.L.3    Hooper, P.K.4    Fulham, M.J.5
  • 6
    • 33846566015 scopus 로고    scopus 로고
    • Derivation and implementation of ordered-subsets algorithms for list-mode PET data
    • Nakayama T and Kudo H 2005 Derivation and implementation of ordered-subsets algorithms for list-mode PET data IEEE Medical Imaging Conf. Record 2005 (M05-7) pp 1950-4
    • (2005) IEEE Medical Imaging Conf. Record 2005 (M05-7) , pp. 1950-1954
    • Nakayama, T.1    Kudo, H.2
  • 8
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L A and Vardi Y 1982 Maximum likelihood reconstruction for emission tomography IEEE Trans. Med. Imaging 1 113-22
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 9
    • 0022142465 scopus 로고
    • The use of sieves to stabilized images produced with the em algorithm for emission tomography
    • Snyder D L and Miller M I 1985 The use of sieves to stabilized images produced with the EM algorithm for emission tomography IEEE Trans. Nucl. Sci. 32 3864-72
    • (1985) IEEE Trans. Nucl. Sci. , vol.32 , pp. 3864-3872
    • Snyder, D.L.1    Miller, M.I.2
  • 10
    • 0031972150 scopus 로고    scopus 로고
    • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET
    • Tanaka E and Amo Y 1998 A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET Phys. Med. Biol. 43 739-46
    • (1998) Phys. Med. Biol. , vol.43 , pp. 739-746
    • Tanaka, E.1    Amo, Y.2
  • 11
    • 0017006622 scopus 로고
    • Correction functions and statistical noise in transverse section picture reconstruction
    • Tanaka E and Iinuma T 1976 Correction functions and statistical noise in transverse section picture reconstruction Comput. Biol. Med. 6 295-306
    • (1976) Comput. Biol. Med. , vol.6 , pp. 295-306
    • Tanaka, E.1    Iinuma, T.2
  • 12
    • 0038458982 scopus 로고    scopus 로고
    • Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography
    • Tanaka E and Kudo H 2003 Subset-dependent relaxation in block-iterative algorithms for image reconstruction in emission tomography Phys. Med. Biol. 48 1405-22
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1405-1422
    • Tanaka, E.1    Kudo, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.