메뉴 건너뛰기




Volumn 7569, Issue , 2010, Pages

Two-photon microscopy with dynamic focusing objective using a liquid lens

Author keywords

Dynamic focusing objective; Liquid lens; Two photon microscopy

Indexed keywords

3-D SPACE; 3D IMAGING; COST-EFFECTIVE SOLUTIONS; DYNAMIC FOCUSING; HIGH RESOLUTION; IMAGING SPEED; LIQUID LENS; MOVING PARTS; TWO PHOTON MICROSCOPY; VARIABLE FOCUS;

EID: 77951755981     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.842581     Document Type: Conference Paper
Times cited : (13)

References (14)
  • 1
    • 0025342635 scopus 로고
    • Two-photon laser scanning fluorescence microscopy
    • W. Denk, J. H. Strickler, and W. W. Webb, "Two-photon laser scanning fluorescence microscopy," Science 248, 73-76 (1990).
    • (1990) Science , vol.248 , pp. 73-76
    • Denk, W.1    Strickler, J.H.2    Webb, W.W.3
  • 2
    • 0000357419 scopus 로고    scopus 로고
    • Two-photon deep tissue ex vivo imaging of mouse dermal and subcutaneous structures
    • P. T. So, H. K. Kim, and I. E. Kochevar, "Two-photon deep tissue ex vivo imaging of mouse dermal and subcutaneous structures," Opt. Exp. 3, 339-350 (1998).
    • (1998) Opt. Exp. , vol.3 , pp. 339-350
    • So, P.T.1    Kim, H.K.2    Kochevar, I.E.3
  • 3
    • 0001366883 scopus 로고    scopus 로고
    • High-speed, two-photon scanning microscope
    • K. Kim, C. Buehler, and P. T. C. So, "High-speed, two-photon scanning microscope," Appl. Opt.,38, 6004-6009, (1999).
    • (1999) Appl. Opt. , vol.38 , pp. 6004-6009
    • Kim, K.1    Buehler, C.2    So, P.T.C.3
  • 4
    • 30944450665 scopus 로고    scopus 로고
    • Deep tissue two-photon microscopy
    • F. Helmchen, and W. Denk, "Deep tissue two-photon microscopy", Nature methods 2, 932-940 (2005).
    • (2005) Nature Methods , vol.2 , pp. 932-940
    • Helmchen, F.1    Denk, W.2
  • 5
    • 0037180832 scopus 로고    scopus 로고
    • Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex
    • J.T. Trachtenberg et. al. "Long-term in vivo imaging of experience-dependent synaptic plasticity in adult cortex", Nature, 420: 788-794 (2002)
    • (2002) Nature , vol.420 , pp. 788-794
    • Trachtenberg, J.T.1
  • 6
    • 0037180796 scopus 로고    scopus 로고
    • Long-term dendritic spine stability in the adult cortex
    • J. Grutzendler et. al. "Long-term dendritic spine stability in the adult cortex", Nature 420:812-816 (2002).
    • (2002) Nature , vol.420 , pp. 812-816
    • Grutzendler, J.1
  • 7
    • 25444487761 scopus 로고    scopus 로고
    • Imaging input and output of neocortical networks in vivo
    • J.N.D. Kerr, D. Greenberg and F. Helmchen, "Imaging input and output of neocortical networks in vivo", Proc. Natl. Acad. Sci. USA 102, 14063-14068 (2005).
    • (2005) Proc. Natl. Acad. Sci. USA , vol.102 , pp. 14063-14068
    • Kerr, J.N.D.1    Greenberg, D.2    Helmchen, F.3
  • 8
    • 33845961471 scopus 로고    scopus 로고
    • Imaging cellular network dynamics in three dimensions using fast 3D laser scanning
    • W. Gobel, et. al. "Imaging cellular network dynamics in three dimensions using fast 3D laser scanning", Nature methods 4:73-79 (2007).
    • (2007) Nature Methods , vol.4 , pp. 73-79
    • Gobel, W.1
  • 9
    • 0033401756 scopus 로고    scopus 로고
    • Construction of a confocal microscope for real-time x-y and x-z imaging
    • N. Callamaras and I. Parker, "Construction of a confocal microscope for real-time x-y and x-z imaging", Cell Calcium, 26, 271-279 (1999)
    • (1999) Cell Calcium , vol.26 , pp. 271-279
    • Callamaras, N.1    Parker, I.2
  • 10
    • 2942720951 scopus 로고    scopus 로고
    • Variable-focus lens with 1-kHz bandwidth
    • H. Oku, K. Hashimoto and M. Ishikawa, "variable-focus lens with 1-kHz bandwidth", Optics Express 12, 2138-2149 (2004).
    • (2004) Optics Express , vol.12 , pp. 2138-2149
    • Oku, H.1    Hashimoto, K.2    Ishikawa, M.3
  • 11
    • 1042300565 scopus 로고    scopus 로고
    • Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror
    • B. Qi, et. al., "Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror", Optics Communications 232, 123-128 (2004).
    • (2004) Optics Communications , vol.232 , pp. 123-128
    • Qi, B.1
  • 13
    • 58349094940 scopus 로고    scopus 로고
    • Three-dimensional adaptive microscopy using embedded liquid lens
    • S. Murali, K. P. Thompson, and J. P. Rolland, "Three-dimensional adaptive microscopy using embedded liquid lens," Opt. Lett. 34, 145-147 (2009).
    • (2009) Opt. Lett. , vol.34 , pp. 145-147
    • Murali, S.1    Thompson, K.P.2    Rolland, J.P.3
  • 14
    • 77951734083 scopus 로고    scopus 로고
    • Assessment of a liquid lens enabled in-vivo optical coherence microscope
    • to appear in May special issue
    • S. Murali, P. Meemon, K. Lee, W. P. Kuhn, K. P. Thompson, and J. P. Rolland "Assessment of a liquid lens enabled in-vivo optical coherence microscope", Applied Optics, to appear in May special issue (2010)
    • (2010) Applied Optics
    • Murali, S.1    Meemon, P.2    Lee, K.3    Kuhn, W.P.4    Thompson, K.P.5    Rolland, J.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.