Volumn 16, Issue 5, 2010, Pages 639-648

Morphometric and simulation analyses of right hepatic vein reconstruction in adult living donor liver transplantation using right lobe grafts

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANATOMICAL VARIATION; ARTICLE; CLINICAL ASSESSMENT; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; GRAFT RECIPIENT; HUMAN; INCIDENCE; INCISION; INFERIOR CAVA VEIN; LIVER DISEASE; LIVER SURGERY; LIVER TRANSPLANTATION; LIVING DONOR; MAJOR CLINICAL STUDY; MALE; MORPHOMETRICS; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RIGHT HEPATIC VEIN RECONSTRUCTION; RIGHT HEPATIC VEIN STENOSIS; RISK FACTOR; SIMULATION; STENOSIS; STENT; SURGICAL TECHNIQUE; THREE DIMENSIONAL IMAGING; VEIN RECONSTRUCTION;

EID: 77951755553     PISSN: 15276465     EISSN: 15276473     Source Type: Journal    
DOI: 10.1002/lt.22045     Document Type: Article
Times cited : (20)

References (25)
  • 3
    • 33645060476 scopus 로고    scopus 로고
    • Techniques of reconstruction of hepatic veins in living-donor liver transplantation, especially for right hepatic vein and major short hepatic veins of right-lobe graft
    • Lee SG. Techniques of reconstruction of hepatic veins in living-donor liver transplantation, especially for right hepatic vein and major short hepatic veins of right-lobe graft. J Hepatobiliary Pancreat Surg 2006;13:131-138.
    • (2006) J Hepatobiliary Pancreat Surg , vol.13 , pp. 131-138
    • Lee, S.G.1
  • 5
    • 60049086158 scopus 로고    scopus 로고
    • Territorial belonging of the middle hepatic vein in living liver donor candidates evaluated by three-dimensional computed tomographic reconstruction and virtual liver resection
    • Radtke A, Sgourakis G, Sotiropoulos GC, Molmenti EP, Saner FH, Timm S, et al. Territorial belonging of the middle hepatic vein in living liver donor candidates evaluated by three-dimensional computed tomographic reconstruction and virtual liver resection. Br J Surg 2009;96:206-213.
    • (2009) Br J Surg , vol.96 , pp. 206-213
    • Radtke, A.1    Sgourakis, G.2    Sotiropoulos, G.C.3    Molmenti, E.P.4    Saner, F.H.5    Timm, S.6
  • 6
    • 34548168031 scopus 로고    scopus 로고
    • An artificial vascular graft is a useful interpositional material for drainage of the right anterior section in living donor liver transplantation
    • DOI 10.1002/lt.21213
    • Yi NJ, Suh KS, Lee HW, Cho EH, Shin WY, Cho JY, Lee KU. An artificial vascular graft is a useful interpositional material for drainage of the right anterior section in living donor liver transplantation. Liver Transpl 2007;13:1159-1167. (Pubitemid 47305035)
    • (2007) Liver Transplantation , vol.13 , Issue.8 , pp. 1159-1167
    • Yi, N.-J.1    Suh, K.-S.2    Lee, H.W.3    Cho, E.-H.4    Shin, W.Y.5    Cho, J.Y.6    Lee, K.U.7
  • 7
    • 34548088196 scopus 로고    scopus 로고
    • Management of the middle hepatic vein and its tributaries in right lobe living donor liver transplantation
    • Yu PF, Wu J, Zheng SS. Management of the middle hepatic vein and its tributaries in right lobe living donor liver transplantation. Hepatobiliary Pancreat Dis Int 2007;6:358-363. (Pubitemid 47288117)
    • (2007) Hepatobiliary and Pancreatic Diseases International , vol.6 , Issue.4 , pp. 358-363
    • Yu, P.-F.1    Wu, J.2    Zheng, S.-S.3
  • 8
    • 57849124142 scopus 로고    scopus 로고
    • Early posttransplant hepatic venous outflow obstruction: Long-term efficacy of primary stent placement
    • Ko GY, Sung KB, Yoon HK, Kim KR, Kim JH, Gwon DI, Lee SG. Early posttransplant hepatic venous outflow obstruction: long-term efficacy of primary stent placement. Liver Transpl 2008;14:1505-1511.
    • (2008) Liver Transpl , vol.14 , pp. 1505-1511
    • Ko, G.Y.1    Sung, K.B.2    Yoon, H.K.3    Kim, K.R.4    Kim, J.H.5    Gwon, D.I.6    Lee, S.G.7
  • 9
    • 12344326825 scopus 로고    scopus 로고
    • Quilt venoplasty using recipient saphenous vein graft for reconstruction of multiple short hepatic veins in right liver grafts
    • DOI 10.1002/lt.20314
    • Hwang S, Lee SG, Park KM, Kim KH, Ahn CS, Moon DB, Ha TY. Quilt venoplasty using recipient saphenous vein graft for reconstruction of multiple short hepatic veins in right liver grafts. Liver Transpl 2005;11:104-107. (Pubitemid 40124450)
    • (2005) Liver Transplantation , vol.11 , Issue.1 , pp. 104-107
    • Hwang, S.1    Lee, S.-G.2    Park, K.-M.3    Kim, K.-H.4    Ahn, C.-S.5    Moon, D.-B.6    Ha, T.-Y.7
  • 13
    • 67650435800 scopus 로고    scopus 로고
    • Computational design of drainage systems for vascularized scaffolds
    • Truslow JG, Price GM, Tien J. Computational design of drainage systems for vascularized scaffolds. Biomaterials 2009;30:4435-4443.
    • (2009) Biomaterials , vol.30 , pp. 4435-4443
    • Truslow, J.G.1    Price, G.M.2    Tien, J.3
  • 14
    • 0342647295 scopus 로고    scopus 로고
    • Hydrodynamics of aortic arch vessels during perfusion through the right subclavian artery
    • DOI 10.1016/S0003-4975(00)01137-1, PII S0003497500011371
    • Gerdes A, Joubert-Hübner E, Esders K, Sievers HH. Hydrodynamics of aortic arch vessels during perfusion through the right subclavian artery. Ann Thorac Surg 2000;69:1425-1430. (Pubitemid 30434870)
    • (2000) Annals of Thoracic Surgery , vol.69 , Issue.5 , pp. 1425-1430
    • Gerdes, A.1    Joubert-Hubner, E.2    Esders, K.3    Sievers, H.-H.4
  • 15
    • 0031159497 scopus 로고    scopus 로고
    • Modeling blood flow in vessels with changeable caliber for physiology and biophysics courses
    • Kozlova EK, Badicov VI, Chemysh AM, Bogushevich MS. Modeling blood flow in vessels with changeable caliber for physiology and biophysics courses. Am J Physiol 1997;272(pt 3):S26-S30.
    • (1997) Am J Physiol , vol.272 , Issue.PART 3
    • Kozlova, E.K.1    Badicov, V.I.2    Chemysh, A.M.3    Bogushevich, M.S.4
  • 16
    • 0342936501 scopus 로고    scopus 로고
    • Numerical simulation of the blood flow in the human cardiovascular system
    • DOI 10.1016/0021-9290(95)00027-5
    • Zacek M, Krause E. Numerical simulation of the blood flow in the human cardiovascular system. J Biomech 1996;29:13-20. (Pubitemid 26009400)
    • (1996) Journal of Biomechanics , vol.29 , Issue.1 , pp. 13-20
    • Zacek, M.1    Krause, E.2
  • 17
    • 33244485044 scopus 로고    scopus 로고
    • Endovascular stent placement for interposed middle hepatic vein graft occlusion after living-donor liver transplantation using right-lobe graft
    • Shin JH, Sung KB, Yoon HK, Ko GY, Kim KW, Lee SG, et al. Endovascular stent placement for interposed middle hepatic vein graft occlusion after living-donor liver transplantation using right-lobe graft. Liver Transpl 2006;12:269-276.
    • (2006) Liver Transpl , vol.12 , pp. 269-276
    • Shin, J.H.1    Sung, K.B.2    Yoon, H.K.3    Ko, G.Y.4    Kim, K.W.5    Lee, S.G.6
  • 18
    • 65449167283 scopus 로고    scopus 로고
    • Sequential preoperative ipsilateral hepatic vein embolization after portal vein embolization to induce further liver regeneration in patients with hepatobiliary malignancy
    • Hwang S, Lee SG, Ko GY, Kim BS, Sung KB, Kim MH, et al. Sequential preoperative ipsilateral hepatic vein embolization after portal vein embolization to induce further liver regeneration in patients with hepatobiliary malignancy. Ann Surg 2009;249:608-616.
    • (2009) Ann Surg , vol.249 , pp. 608-616
    • Hwang, S.1    Lee, S.G.2    Ko, G.Y.3    Kim, B.S.4    Sung, K.B.5    Kim, M.H.6
  • 19
    • 34247217968 scopus 로고    scopus 로고
    • Doppler sonographic abnormalities suggestive of venous congestion in the right lobe graft of living donor liver transplant recipients
    • Kim KW, Kim TK, Kim SY, Kim MJ, Park MS, Lee MG, Lee SG. Doppler sonographic abnormalities suggestive of venous congestion in the right lobe graft of living donor liver transplant recipients. AJR Am J Roentgenol 2007;188:W239-W245.
    • (2007) AJR Am J Roentgenol , vol.188
    • Kim, K.W.1    Kim, T.K.2    Kim, S.Y.3    Kim, M.J.4    Park, M.S.5    Lee, M.G.6    Lee, S.G.7
  • 20
    • 42449117912 scopus 로고    scopus 로고
    • Doppler sonography to diagnose venous congestion in a modified right lobe graft after living donor liver transplantation
    • DOI 10.2214/AJR.07.2825
    • Kim SY, Kim KW, Lee SS, Song GW, Hwang S, Kim PN, Lee SG. Doppler sonography to diagnose venous congestion in a modified right lobe graft after living donor liver transplantation. AJR Am J Roentgenol 2008;190:1010-1017. (Pubitemid 351571498)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.4 , pp. 1010-1017
    • So, Y.K.1    Kim, K.W.2    Seung, S.L.3    Song, G.-W.4    Hwang, S.5    Pyo, N.K.6    Sung, G.L.7
  • 22
    • 34147168189 scopus 로고    scopus 로고
    • Hepatic venous congestion after right-lobe living-donor liver transplantation: The added value of delayed-phase imaging on CT
    • Park EA, Lee JM, Kim SH, Lee MW, Han JK, Choi BI, et al. Hepatic venous congestion after right-lobe living-donor liver transplantation: the added value of delayed-phase imaging on CT. J Comput Assist Tomogr 2007;31:181-187.
    • (2007) J Comput Assist Tomogr , vol.31 , pp. 181-187
    • Park, E.A.1    Lee, J.M.2    Kim, S.H.3    Lee, M.W.4    Han, J.K.5    Choi, B.I.6
  • 23
    • 57849147595 scopus 로고    scopus 로고
    • Caudal shifting of hepatic vein anastomosis in right liver living donor liver transplantation
    • Fan ST. Caudal shifting of hepatic vein anastomosis in right liver living donor liver transplantation. Hepatobiliary Pancreat Dis Int 2008;7:654-657.
    • (2008) Hepatobiliary Pancreat Dis Int , vol.7 , pp. 654-657
    • Fan, S.T.1
  • 24
    • 33645104098 scopus 로고    scopus 로고
    • Outflow vein reconstruction of extended right lobe graft using quilt venoplasty technique
    • Hwang S, Lee SG, Ahn CS, Moon DB, Kim KH, Ha TY, Song GW. Outflow vein reconstruction of extended right lobe graft using quilt venoplasty technique. Liver Transpl 2006;12:156-158.
    • (2006) Liver Transpl , vol.12 , pp. 156-158
    • Hwang, S.1    Lee, S.G.2    Ahn, C.S.3    Moon, D.B.4    Kim, K.H.5    Ha, T.Y.6    Song, G.W.7