메뉴 건너뛰기




Volumn 23, Issue , 2009, Pages 825-828

LED Based Sensor System for Non-Invasive Measurement of the Hemoglobin Concentration in Human Blood

Author keywords

Hemoglobin; Non invasive; Photoplethysmography

Indexed keywords

DIAGNOSTIC PARAMETER; HEMOGLOBIN CONCENTRATION; NON-INVASIVE; NONINVASIVE MEASUREMENTS; NONINVASIVE METHODS; OXYGEN SATURATION; PHYSIOLOGICAL CONDITION; REAL-TIME DATA MONITORING;

EID: 77951748734     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-92841-6_203     Document Type: Conference Paper
Times cited : (24)

References (10)
  • 2
    • 0028081969 scopus 로고
    • Use of the water absorption spectrumto quantifies tissue chromospheres concentration changes in near-infrared spectroscopy
    • September
    • S. J. Matcher, M. Cope, and D. T. Delpy. Use of the water absorption spectrumto quantifies tissue chromospheres concentration changes in near-infrared spectroscopy. Phys. Med. Biol., 38:177-196, September 1993.
    • (1993) Phys. Med. Biol , vol.38 , pp. 177-196
    • Matcher, S.J.1    Cope, M.2    Delpy, D.T.3
  • 3
    • 0025833944 scopus 로고
    • Valsalva maneuver in obstetrics: The influence of peripheral circulatory changes on function of the pulse oximeter
    • Woods AM, Queen, JS, Lawson D., 1991 Valsalva maneuver in obstetrics: The influence of peripheral circulatory changes on function of the pulse oximeter, Anesth. Analg. 73 pp. 765-71
    • (1991) Anesth. Analg , vol.73 , pp. 765-771
    • Woods, A.M.1    Queen, J.S.2    Lawson, D.3
  • 7
    • 77951124329 scopus 로고    scopus 로고
    • Results of hemoglobin concentration measurements in whole blood with an optical non-invasive method
    • Edinburgh UK
    • Kratil, J., Ewald H., Results of hemoglobin concentration measurements in whole blood with an optical non-invasive method", Photon08, Optics and Photonics, IOP Conference, p 77, Edinburgh UK, 2008
    • (2008) Photon08, Optics and Photonics, IOP Conference , pp. 77
    • Kratil, J.1    Ewald, H.2
  • 8
    • 65249139613 scopus 로고    scopus 로고
    • Non-Invasive Wireless Sensor System for Measurement of Hemoglobin Concentration in Human Blood
    • September 10th-12th, Rostock, Germany, ISBN: 978-3-938042-17-54
    • U. Timm, E. Lewis, H. Ewald, "Non-Invasive Wireless Sensor System for Measurement of Hemoglobin Concentration in Human Blood", 6th International Forum Life Science Automation (LSA) 2008, September 10th-12th, Rostock, Germany, ISBN: 978-3-938042-17-54
    • (2008) 6th International Forum Life Science Automation (LSA)
    • Timm, U.1    Lewis, E.2    Ewald, H.3
  • 10
    • 0021489638 scopus 로고
    • Effects of multiple scattering and pheripheral circulation on aterial oxygen saturation measured with pulse type oximeter
    • Yosihida I, Shimada Y, Oka N, Hamaguri K, 1984, Effects of multiple scattering and pheripheral circulation on aterial oxygen saturation measured with pulse type oximeter, Med & Biol. Eng & Comput., 22, pp 475-78
    • (1984) Med & Biol. Eng & Comput , vol.22 , pp. 475-478
    • Yosihida, I.1    Shimada, Y.2    Oka, N.3    Hamaguri, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.