Volumn 31, Issue 5, 2010, Pages 404-411

Impact of talar component rotation on contact pressure after total ankle arthroplasty: A cadaveric study

Author keywords

Component rotation; Contact pressure; Total ankle arthroplasty

Indexed keywords

POLYETHYLENE;

EID: 77951727504     PISSN: 10711007     EISSN: None     Source Type: Journal    
DOI: 10.3113/FAI.2010.0404     Document Type: Article
Times cited : (68)

References (19)
  • 1
    • 0023007566 scopus 로고
    • The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
    • Bartel, DL; Bicknell, VL; Wright, TM: The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 68:1041-1051, 1986.
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1041-1051
    • Bartel, D.L.1    Bicknell, V.L.2    Wright, T.M.3
  • 4
    • 3042785704 scopus 로고    scopus 로고
    • Accurate measurement of ankle range of motion after total ankle arthroplasty
    • Coetzee, JC; Castro, MD: Accurate measurement of ankle range of motion after total ankle arthroplasty. Clin Orthop Relat Res. 424:27-31, 2004. (Pubitemid 38890853)
    • (2004) Clinical Orthopaedics and Related Research , Issue.424 , pp. 27-31
    • Coetzee, J.C.1    Castro, M.D.2
  • 5
    • 0035167668 scopus 로고    scopus 로고
    • Polyethylene Contact Stresses, Articular Congruity, and Knee Alignment
    • D'Lima, DD; Chen, PC; Colwell, CW Jr: Polyethylene Contact Stresses, Articular Congruity, and Knee Alignment. Clin Ortho Relat Res. 392:232-238, 2001.
    • (2001) Clin Ortho Relat Res , vol.392 , pp. 232-238
    • D'Lima, D.D.1    Chen, P.C.2    Colwell Jr., C.W.3
  • 8
    • 33847631588 scopus 로고    scopus 로고
    • Outcome analysis of Agility® total ankle replacement with prior adjunctive procedures: Two to six year follow-up
    • Hurowitz, EJ; Gould, JS; Fleisig, GS; Fowler, R: Outcome analysis of Agility® total ankle replacement with prior adjunctive procedures: two to six year follow-up. Foot Ankle Int. 28(3):308-312, 2007.
    • (2007) Foot Ankle Int , vol.28 , Issue.3 , pp. 308-312
    • Hurowitz, E.J.1    Gould, J.S.2    Fleisig, G.S.3    Fowler, R.4
  • 9
    • 0026046584 scopus 로고
    • Age-related changes in the tensile properties of human articular cartilage: A comparative study between the femoral head of the hip joint and the talus of the ankle joint
    • Kempson, GE: Age-related changes in the tensile properties of human articular cartilage: a comparative study between the femoral head of the hip joint and the talus of the ankle joint. Biochimica et Biophysica Acta. 1075(3):223-230, 1991.
    • (1991) Biochimica et Biophysica Acta , vol.1075 , Issue.3 , pp. 223-230
    • Kempson, G.E.1
  • 11
    • 0035379922 scopus 로고    scopus 로고
    • Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees
    • Matsuda, S; Miura, H; Nagamine, R; et al.: Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg. 14(3):152-156, 2001.
    • (2001) Am J Knee Surg , vol.14 , Issue.3 , pp. 152-156
    • Matsuda, S.1    Miura, H.2    Nagamine, R.3
  • 16
    • 0018537364 scopus 로고
    • Contact pressure dependence of wear rates of ultra high molecular weight polyethylene
    • Rostoker, W; Galante, JO: Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. J Biomed Mater Res. 13(6):957-964, 1979.
    • (1979) J Biomed Mater Res , vol.13 , Issue.6 , pp. 957-964
    • Rostoker, W.1    Galante, J.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.