메뉴 건너뛰기




Volumn 75, Issue 6, 2010, Pages 964-966

Over-and-under pericardial covered stent with paclitaxel balloon in a saphenous vein graft

Author keywords

Bypass grafts coronary (GRFT); Drug delivery (DDEL); Embolization (EMBO); Intravascular ultrasound (IVUS); No reflow (NRFL); Percutaneous coronary intervention (PCI)

Indexed keywords

DIOR; EVEROLIMUS; INSULIN; PACLITAXEL; UNCLASSIFIED DRUG;

EID: 77951722148     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.22412     Document Type: Article
Times cited : (5)

References (9)
  • 2
    • 39549122242 scopus 로고    scopus 로고
    • Saphenous vein graft stenting and major adverse cardiac events: A predictive model derived from a pooled analysis of 3958 patients
    • Coolong A, Baim DS, Kuntz RE, O'Malley AJ, Marulkar S, Cutlip DE, Popma JJ, Mauri L. Saphenous vein graft stenting and major adverse cardiac events: A predictive model derived from a pooled analysis of 3958 patients. Circulation 2008;117:790-797.
    • (2008) Circulation , vol.117 , pp. 790-797
    • Coolong, A.1    Baim, D.S.2    Kuntz, R.E.3    O'Malley, A.J.4    Marulkar, S.5    De Cutlip6    Popma, J.J.7    Mauri, L.8
  • 3
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • Baim DS, Wahr D, George B, Leon MB, Greenberg J, Cutlip DE, Kaya U, Popma JJ, Ho KK, Kuntz RE. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation 2002;105:1285-1290.
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3    Leon, M.B.4    Greenberg, J.5    De Cutlip6    Kaya, U.7    Popma, J.J.8    Ho, K.K.9    Kuntz, R.E.10
  • 6
    • 79960739365 scopus 로고    scopus 로고
    • Pericardium covered stent: A novel device for treatment and prevention of coronary emergencies
    • Danenberg H. Pericardium covered stent: A novel device for treatment and prevention of coronary emergencies. EuroIntervention 2009;Suppl E.
    • (2009) EuroIntervention , Issue.SUPPL. E
    • Danenberg, H.1
  • 7
    • 52449104783 scopus 로고    scopus 로고
    • Two year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter
    • Scheller B, Hehrlein C, Bocksch W, Rutsch W, Haghi D, Dietz U, Bohm M, Speck U. Two year follow-up after treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. Clin Res Cardiol 2008;97:773-781.
    • (2008) Clin Res Cardiol , vol.97 , pp. 773-781
    • Scheller, B.1    Hehrlein, C.2    Bocksch, W.3    Rutsch, W.4    Haghi, D.5    Dietz, U.6    Bohm, M.7    Speck, U.8
  • 9
    • 4143067824 scopus 로고    scopus 로고
    • Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis
    • Scheller B, Speck U, Abramjuk C, Bernhardt U, Bohm M, Nickenig G. Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis. Circulation 2004;110:810-814.
    • (2004) Circulation , vol.110 , pp. 810-814
    • Scheller, B.1    Speck, U.2    Abramjuk, C.3    Bernhardt, U.4    Bohm, M.5    Nickenig, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.