메뉴 건너뛰기




Volumn 25, Issue 2, 2010, Pages 885-893

Analysis of transient stability enhancement of LV-connected induction microgenerators by using resistive-type fault current limiters

Author keywords

Distribution networks; Fault current limiters; Single phase induction generators; Transient stability

Indexed keywords

ANALYTICAL METHOD; DETAILED MODELS; DISTRIBUTION NETWORK; DYNAMIC SIMULATION; FAULT CLEARANCE; FAULT CURRENT LIMITER; INDUCTION MACHINES; LOW-VOLTAGE; MACHINE PARAMETERS; MICRO-WIND TURBINES; MICROGENERATION; MICROGENERATORS; PSCAD/EMTDC; REMEDIAL MEASURES; RESIDENTIAL DWELLING; RESIDENTIAL LOADS; RESISTIVE ELEMENTS; RESISTIVE SUPERCONDUCTING FAULT CURRENT LIMITER; RESISTIVE TYPE; SINGLE-PHASE INDUCTION GENERATOR; SPEED LIMIT; SUPERCONDUCTING FAULT CURRENT LIMITERS; TIME DOMAIN; TRANSIENT INSTABILITY; TRANSIENT MODEL; TRANSIENT STABILITY; TRANSIENT STUDIES; UNBALANCED VOLTAGE CONDITION;

EID: 77951667174     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2009.2034859     Document Type: Article
Times cited : (50)

References (20)
  • 1
    • 77951667074 scopus 로고    scopus 로고
    • Department for Business Enterprise and Regulatory Reform, Microgeneration Strategy, Progress Report [Online] Available:
    • Department for Business Enterprise and Regulatory Reform, Microgeneration Strategy, Progress Report, BERR, 2008. [Online]. Available: http://www.berr.gov.uk/whatwedo/energy/sources/sustain-able/microgeneration/ strategy/page27594.html.
    • (2008)
  • 6
    • 0035304577 scopus 로고    scopus 로고
    • Investigating the impact of embedded generation on relay settings of utilities' electrical feeders
    • Apr.
    • S. K. Salman and I. M. Rida, "Investigating the impact of embedded generation on relay settings of utilities' electrical feeders," IEEE Trans. Power Del., vol. 16, no. 2, pp. 246-251, Apr. 2001.
    • (2001) IEEE Trans. Power Del. , vol.16 , Issue.2 , pp. 246-251
    • Salman, S.K.1    Rida, I.M.2
  • 8
    • 2542511558 scopus 로고    scopus 로고
    • Improvement of induction generator stability using braking resistors
    • May
    • W. Freitas, A. Morelato, and W. Xu, "Improvement of induction generator stability using braking resistors," IEEE Tran. Power Syst., vol. 19, no. 2, pp. 1247-1249, May 2004.
    • (2004) IEEE Tran. Power Syst. , vol.19 , Issue.2 , pp. 1247-1249
    • Freitas, W.1    Morelato, A.2    Xu, W.3
  • 11
    • 45149108603 scopus 로고    scopus 로고
    • Practical application issues of superconducting fault current limiters for electric power systems
    • Jun.
    • B. W. Lee, J. Sim, K. B. Park, and I. S. Oh, "Practical application issues of superconducting fault current limiters for electric power systems," IEEE Trans. Appl. Superconduct., vol. 18, no. 2, pp. 620-623, Jun. 2008.
    • (2008) IEEE Trans. Appl. Superconduct. , vol.18 , Issue.2 , pp. 620-623
    • Lee, B.W.1    Sim, J.2    Park, K.B.3    Oh, I.S.4
  • 13
    • 36349022069 scopus 로고    scopus 로고
    • An analytical method for analysis of large-disturbance stability of induction generators
    • Nov.
    • A. P. Grilo, A. A. Mota, L. T. Mota, and W. Freitas, "An analytical method for analysis of large-disturbance stability of induction generators," IEEE Trans. Power Syst., vol. 22, no. 4, pp. 1861-1869, Nov. 2007.
    • (2007) IEEE Trans. Power Syst. , vol.22 , Issue.4 , pp. 1861-1869
    • Grilo, A.P.1    Mota, A.A.2    Mota, L.T.3    Freitas, W.4
  • 14
    • 13344280943 scopus 로고    scopus 로고
    • Study of dynamic behavior of grid connected induction generators
    • Jun.
    • K. C. Divya and P. S. N. Rao, "Study of dynamic behavior of grid connected induction generators," in Proc. IEEE Power Eng. Soc. General Meeting, Jun. 2004, vol. 2, pp. 2200-2205.
    • (2004) Proc. IEEE Power Eng. Soc. General Meeting , vol.2 , pp. 2200-2205
    • Divya, K.C.1    Rao, P.S.N.2
  • 15
    • 0242673228 scopus 로고
    • Power system stability and control
    • New York: McGraw Hill
    • P. Kundur, Power System Stability and Control, ser. Power System Engineering Series. New York: McGraw Hill, 1994, pp. 271-273.
    • (1994) Ser. Power System Engineering Series , pp. 271-273
    • Kundur, P.1
  • 16
    • 77951666547 scopus 로고    scopus 로고
    • Transient Analysis for PSCAD Power System Simulation User Guide, EMTDC TM, Manitoba HVDC Research Centre
    • Transient Analysis for PSCAD Power System Simulation User Guide, EMTDC TM, Manitoba HVDC Research Centre.
  • 17
    • 0004811631 scopus 로고
    • The transient and qualitative performance of a self-excited single phase induction generator
    • Sep.
    • O. Ojo, "The transient and qualitative performance of a self-excited single phase induction generator," IEEE Trans. Energy Convers., vol. 10, no. 3, pp. 493-501, Sep. 1995.
    • (1995) IEEE Trans. Energy Convers. , vol.10 , Issue.3 , pp. 493-501
    • Ojo, O.1
  • 18
    • 0141754112 scopus 로고    scopus 로고
    • Design-based performance evaluation of two-winding capacitor self-excited single-phase induction generator
    • K. Tiwari, S. Murthy, B. Singh, and L. Shridhar, "Design-based performance evaluation of two-winding capacitor self-excited single-phase induction generator," Elect. Power Syst. Res., vol. 67, pp. 89-97, 2003.
    • (2003) Elect. Power Syst. Res. , vol.67 , pp. 89-97
    • Tiwari, K.1    Murthy, S.2    Singh, B.3    Shridhar, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.