메뉴 건너뛰기




Volumn 14, Issue 2, 2010, Pages 142-146

Final Version of the Distance Randot Stereotest: Normative data, reliability, and validity

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BINOCULAR VISION; CHILD; CONTROLLED STUDY; CONVALESCENCE; DISTANCE PERCEPTION; HUMAN; INSTRUMENT VALIDATION; MAJOR CLINICAL STUDY; OPTICAL INSTRUMENTATION; PRESCHOOL CHILD; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SCHOOL CHILD; SENSITIVITY ANALYSIS; STEREOSCOPIC VISION; STRABISMUS; STRABISMUS SURGERY; TEST RETEST RELIABILITY; VALIDITY; VISION TEST; VISUAL ACUITY;

EID: 77951665755     PISSN: 10918531     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jaapos.2009.12.159     Document Type: Article
Times cited : (40)

References (18)
  • 1
    • 41949085190 scopus 로고    scopus 로고
    • Improvement in distance stereoacuity following surgery for intermittent exotropia
    • Adams W.E., Leske D.A., Hatt S.R., et al. Improvement in distance stereoacuity following surgery for intermittent exotropia. J AAPOS 12 (2008) 141-144
    • (2008) J AAPOS , vol.12 , pp. 141-144
    • Adams, W.E.1    Leske, D.A.2    Hatt, S.R.3
  • 2
    • 11844306015 scopus 로고    scopus 로고
    • Testing distance stereoacuity with the Frisby-Davis 2 (FD2) test
    • Holmes J.M., and Fawcett S.L. Testing distance stereoacuity with the Frisby-Davis 2 (FD2) test. Am J Ophthalmol 139 (2005) 193-195
    • (2005) Am J Ophthalmol , vol.139 , pp. 193-195
    • Holmes, J.M.1    Fawcett, S.L.2
  • 4
    • 0027514303 scopus 로고
    • Distance stereoacuity: Assessing control in intermittent exotropia
    • Stathacopoulos R.A., Rosenbaum A.L., Zanoni D., et al. Distance stereoacuity: Assessing control in intermittent exotropia. Ophthalmology 100 (1993) 495-500
    • (1993) Ophthalmology , vol.100 , pp. 495-500
    • Stathacopoulos, R.A.1    Rosenbaum, A.L.2    Zanoni, D.3
  • 5
    • 33750321693 scopus 로고    scopus 로고
    • Assessment of a new Distance Randot stereoacuity test
    • Fu V.L., Birch E.E., and Holmes J.M. Assessment of a new Distance Randot stereoacuity test. J AAPOS 10 (2006) 419-423
    • (2006) J AAPOS , vol.10 , pp. 419-423
    • Fu, V.L.1    Birch, E.E.2    Holmes, J.M.3
  • 6
    • 1242283865 scopus 로고    scopus 로고
    • Maximum angle of horizontal strabismus consistent with true stereopsis
    • Leske D.A., and Holmes J.M. Maximum angle of horizontal strabismus consistent with true stereopsis. J AAPOS 8 (2004) 28-34
    • (2004) J AAPOS , vol.8 , pp. 28-34
    • Leske, D.A.1    Holmes, J.M.2
  • 7
    • 34249731099 scopus 로고    scopus 로고
    • New tests of distance stereoacuity and their role in evaluating intermittent exotropia
    • Holmes J.M., Birch E.E., Leske D.A., Fu V.L., and Mohney B.G. New tests of distance stereoacuity and their role in evaluating intermittent exotropia. Ophthalmology 114 (2007) 1215-1220
    • (2007) Ophthalmology , vol.114 , pp. 1215-1220
    • Holmes, J.M.1    Birch, E.E.2    Leske, D.A.3    Fu, V.L.4    Mohney, B.G.5
  • 8
    • 41949130060 scopus 로고    scopus 로고
    • Normative pediatric visual acuity using single surrounded HOTV optotypes on the Electronic Visual Acuity Tester following the Amblyopia Treatment Study protocol
    • Drover J.R., Felius J., Cheng C.S., Morale S.E., Wyatt L., and Birch E.E. Normative pediatric visual acuity using single surrounded HOTV optotypes on the Electronic Visual Acuity Tester following the Amblyopia Treatment Study protocol. J AAPOS 12 (2008) 145-149
    • (2008) J AAPOS , vol.12 , pp. 145-149
    • Drover, J.R.1    Felius, J.2    Cheng, C.S.3    Morale, S.E.4    Wyatt, L.5    Birch, E.E.6
  • 9
    • 0141458932 scopus 로고    scopus 로고
    • Reliability of the electronic early treatment diabetic retinopathy study testing protocol in children 7 to <13 years old
    • Cotter S.A., Chu R.H., Chandler D.L., et al. Reliability of the electronic early treatment diabetic retinopathy study testing protocol in children 7 to <13 years old. Am J Ophthalmol 136 (2003) 655-661
    • (2003) Am J Ophthalmol , vol.136 , pp. 655-661
    • Cotter, S.A.1    Chu, R.H.2    Chandler, D.L.3
  • 10
    • 0030807976 scopus 로고    scopus 로고
    • Random dot stereoacuity of preschool children. ALSPAC "Children in Focus" Study Team
    • quiz 247-8
    • Birch E., Williams C., Hunter J., and Lapa M.C. Random dot stereoacuity of preschool children. ALSPAC "Children in Focus" Study Team. J Pediatr Ophthalmol Strabismus 34 (1997) 217-222 quiz 247-8
    • (1997) J Pediatr Ophthalmol Strabismus , vol.34 , pp. 217-222
    • Birch, E.1    Williams, C.2    Hunter, J.3    Lapa, M.C.4
  • 11
    • 39149142209 scopus 로고    scopus 로고
    • Variability of stereoacuity in intermittent exotropia
    • Hatt S.R., Mohney B.G., Leske D.A., and Holmes J.M. Variability of stereoacuity in intermittent exotropia. Am J Ophthalmol 145 (2008) 556-561
    • (2008) Am J Ophthalmol , vol.145 , pp. 556-561
    • Hatt, S.R.1    Mohney, B.G.2    Leske, D.A.3    Holmes, J.M.4
  • 12
    • 34547575463 scopus 로고    scopus 로고
    • Stereoacuity and binocular visual acuity in prism-induced exodeviation
    • Laird P.W., Hatt S.R., Leske D.A., and Holmes J.M. Stereoacuity and binocular visual acuity in prism-induced exodeviation. J AAPOS 11 (2007) 362-366
    • (2007) J AAPOS , vol.11 , pp. 362-366
    • Laird, P.W.1    Hatt, S.R.2    Leske, D.A.3    Holmes, J.M.4
  • 13
    • 49149090026 scopus 로고    scopus 로고
    • Distance stereoacuity in prism-induced convergence stress
    • Laird P.W., Hatt S.R., Leske D.A., and Holmes J.M. Distance stereoacuity in prism-induced convergence stress. J AAPOS 12 (2008) 370-374
    • (2008) J AAPOS , vol.12 , pp. 370-374
    • Laird, P.W.1    Hatt, S.R.2    Leske, D.A.3    Holmes, J.M.4
  • 14
    • 64749108112 scopus 로고    scopus 로고
    • The effect of induced monocular blur on measures of stereoacuity
    • Odell N.V., Hatt S.R., Leske D.A., Adams W.E., and Holmes J.M. The effect of induced monocular blur on measures of stereoacuity. J AAPOS 13 (2009) 136-141
    • (2009) J AAPOS , vol.13 , pp. 136-141
    • Odell, N.V.1    Hatt, S.R.2    Leske, D.A.3    Adams, W.E.4    Holmes, J.M.5
  • 15
    • 0028784518 scopus 로고
    • Distance stereo acuity improvement in intermittent exotropic patients following strabismus surgery
    • discussion 358
    • O'Neal T.D., Rosenbaum A.L., and Stathacopoulos R.A. Distance stereo acuity improvement in intermittent exotropic patients following strabismus surgery. J Pediatr Ophthalmol Strabismus 32 (1995) 353-357 discussion 358
    • (1995) J Pediatr Ophthalmol Strabismus , vol.32 , pp. 353-357
    • O'Neal, T.D.1    Rosenbaum, A.L.2    Stathacopoulos, R.A.3
  • 16
    • 0345034807 scopus 로고    scopus 로고
    • Assessment of central and peripheral fusion and near and distance stereoacuity in intermittent exotropic patients before and after strabismus surgery
    • Yildirim C., Mutlu F.M., Chen Y., and Altinsoy H.I. Assessment of central and peripheral fusion and near and distance stereoacuity in intermittent exotropic patients before and after strabismus surgery. Am J Ophthalmol 128 (1999) 222-230
    • (1999) Am J Ophthalmol , vol.128 , pp. 222-230
    • Yildirim, C.1    Mutlu, F.M.2    Chen, Y.3    Altinsoy, H.I.4
  • 17
    • 34548685334 scopus 로고    scopus 로고
    • Atypical fixation preference with anisometropia
    • Rutstein R.P., and Swanson M.W. Atypical fixation preference with anisometropia. Optom Vis Sci 84 (2007) 848-851
    • (2007) Optom Vis Sci , vol.84 , pp. 848-851
    • Rutstein, R.P.1    Swanson, M.W.2
  • 18
    • 11344288486 scopus 로고    scopus 로고
    • Incidence and types of childhood exotropia: A population-based study
    • Govindan M., Mohney B.G., Diehl N.N., and Burke J.P. Incidence and types of childhood exotropia: A population-based study. Ophthalmology 112 (2005) 104-108
    • (2005) Ophthalmology , vol.112 , pp. 104-108
    • Govindan, M.1    Mohney, B.G.2    Diehl, N.N.3    Burke, J.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.