메뉴 건너뛰기




Volumn 37, Issue 6, 2009, Pages 403-406

An unusual cause of OptiVol alarm: Increased intra-abdominal pressure associated with irritable bowel syndrome

Author keywords

Abdomen; Body fluids physiology; Cardiography; Defibrillators; Heart failure; Hemodynamics; Impedance; Implantable; Pressure

Indexed keywords

ARTICLE; BODY FLUID; CASE REPORT; CONGESTIVE CARDIOMYOPATHY; DEFIBRILLATOR; ENVIRONMENTAL MONITORING; HEART FAILURE; HEART STROKE VOLUME; HUMAN; IRRITABLE COLON; MALE; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 77951631819     PISSN: 10165169     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (8)
  • 1
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • DOI 10.1161/CIRCULATIONAHA.104.492207
    • Yu CM, Wang L, Chau E, Chan RH, Kong SL, Tang MO, et al. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 2005;112:841-8. (Pubitemid 41170070)
    • (2005) Circulation , vol.112 , Issue.6 , pp. 841-848
    • Yu, C.-M.1    Wang, L.2    Chau, E.3    Chan, R.H.-W.4    Kong, S.-L.5    Tang, M.-O.6    Christensen, J.7    Stadler, R.W.8    Lau, C.-P.9
  • 2
    • 34248572239 scopus 로고    scopus 로고
    • Fundamentals of intrathoracic impedance monitoring in heart failure
    • Wang L. Fundamentals of intrathoracic impedance monitoring in heart failure. Am J Cardiol 2007;99:3G-10G.
    • (2007) Am J Cardiol , vol.99
    • Wang, L.1
  • 4
    • 79959555109 scopus 로고    scopus 로고
    • Surgical revision of implantable device "pocket"or lead can alter thoracic impedance-based indices of worsening heart failure
    • Repoley JL, Dukes-Graves D, Kiser C, Worley SJ, Gohn DC. Surgical revision of implantable device "pocket"or lead can alter thoracic impedance-based indices of worsening heart failure. J Card Fail 2006;12:S66.
    • (2006) J Card Fail , vol.12
    • Repoley, J.L.1    Dukes-Graves, D.2    Kiser, C.3    Worley, S.J.4    Gohn, D.C.5
  • 5
    • 34248596423 scopus 로고    scopus 로고
    • Key lessons from cases worldwide
    • Wang L. Key lessons from cases worldwide. Am J Cardiol 2007;99:34G-40G.
    • (2007) Am J Cardiol , vol.99
    • Wang, L.1
  • 6
    • 33645258440 scopus 로고    scopus 로고
    • Changes in intrathoracic impedance from a pneumothorax: Insights from an implanted monitoring system
    • DOI 10.1111/j.1540-8159.2005.00235.x
    • Timperley J, Mitchell AR, Brown P, Betts TR. Changes in intrathoracic impedance from a pneumothorax: insights from an implanted monitoring system. Pacing Clin Electrophysiol 2005;28:1109-11. (Pubitemid 43951415)
    • (2005) PACE - Pacing and Clinical Electrophysiology , vol.28 , Issue.10 , pp. 1109-1111
    • Timperley, J.1    Mitchell, A.R.J.2    Brown, P.3    Betts, T.R.4
  • 7
    • 0030970872 scopus 로고    scopus 로고
    • A proposed relationship between increased intra-abdominal, intrathoracic, and intracranial pressure
    • DOI 10.1097/00003246-199703000-00020
    • Bloomfield GL, Ridings PC, Blocher CR, Marmarou A, Sugerman HJ. A proposed relationship between increased intra-abdominal, intrathoracic, and intracranial pressure. Crit Care Med 1997;25:496-503. (Pubitemid 27152746)
    • (1997) Critical Care Medicine , vol.25 , Issue.3 , pp. 496-503
    • Bloomfield, G.L.1    Ridings, P.C.2    Blocher, C.R.3    Marmarou, A.4    Sugerman, H.J.5
  • 8
    • 34250816367 scopus 로고    scopus 로고
    • Intra-abdominal pressure on the functions of abdominal and thoracic organs
    • Abstract
    • Cernea D, Cernea N, Berteanu C. Intra-abdominal pressure on the functions of abdominal and thoracic organs. Rev Med Chir Soc Med Nat Iasi 2006;110:929-37. [Abstract]
    • (2006) Rev Med Chir Soc Med Nat Iasi , vol.110 , pp. 929-937
    • Cernea, D.1    Cernea, N.2    Berteanu, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.