메뉴 건너뛰기




Volumn 7564, Issue , 2010, Pages

Fine-resolution photoacoustic imaging of the eye

Author keywords

Eye; Photoacoustic; Ultrasound

Indexed keywords

1064 NM; BEAM WIDTHS; DIAGNOSTIC IMAGING; EX-VIVO; IN-VIVO; LASER SPOT SIZE; LATERAL RESOLUTION; LINEAR STAGES; MACULAR DEGENERATION; OPHTHALMIC IMAGING; OPTICAL ABSORPTION; OPTICAL COHERENCE TOMOGRAPHY; ORDER OF MAGNITUDE; OXY-AND DEOXY-HEMOGLOBIN; PHOTO-ACOUSTIC IMAGING; PHOTOACOUSTIC IMAGE; PHOTOACOUSTIC SIGNALS; PHOTOACOUSTIC SYSTEMS; PROTOTYPE SYSTEM; PULSE ECHO ULTRASOUND; REPETITION RATE; SPOT SIZES; ULTRASOUND PROBES;

EID: 77951584761     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.842471     Document Type: Conference Paper
Times cited : (9)

References (24)
  • 2
    • 3042565175 scopus 로고    scopus 로고
    • High-resolution ultrasonic imaging of the posterior segment
    • DOI 10.1016/j.ophtha.2003.10.029, PII S0161642004001551
    • Coleman, D.J., Silverman, R.H., Chabi, A., Rondeau, M.J., Shung, K.K., Cannata, J. and Lincoff, H., "High resolution ultrasonic imaging of the posterior segment," Ophthalmology 111, 1344-1351 (2004). (Pubitemid 38844833)
    • (2004) Ophthalmology , vol.111 , Issue.7 , pp. 1344-1351
    • Coleman, D.J.1    Silverman, R.H.2    Chabi, A.3    Rondeau, M.J.4    Shung, K.K.5    Cannata, J.6    Lincoff, H.7
  • 3
    • 0442326648 scopus 로고    scopus 로고
    • Design of efficient, broadband single element (20 - 80 MHz) ultrasonic transducers for medical imaging applications
    • Cannata, J., Ritter, T., Chen, W-H., Silverman, R.H. and Shung, K.K., "Design of efficient, broadband single element (20 - 80 MHz) ultrasonic transducers for medical imaging applications," IEEE Trans. Ultrason., Ferroelectr., Frequ. Contr. 50(11), 1548-1557 (2003).
    • (2003) IEEE Trans. Ultrason., Ferroelectr., Frequ. Contr. , vol.50 , Issue.11 , pp. 1548-1557
    • Cannata, J.1    Ritter, T.2    Chen, W.-H.3    Silverman, R.H.4    Shung, K.K.5
  • 4
    • 1842452732 scopus 로고    scopus 로고
    • A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit
    • Hewick, S.A., Fairhead, A.C., Culy, J.C. and Atta, H.R., "A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit," Br. J. Ophthalmol. 88, 551-555 (2004).
    • (2004) Br. J. Ophthalmol. , vol.88 , pp. 551-555
    • Hewick, S.A.1    Fairhead, A.C.2    Culy, J.C.3    Atta, H.R.4
  • 6
    • 4444312568 scopus 로고    scopus 로고
    • Static and dynamic analysis of the anterior segment with optical coherence tomography
    • Baikoff, G., Lutun, E., Ferraz, C. and Wei, J., "Static and dynamic analysis of the anterior segment with optical coherence tomography," J. Cataract Refract. Surg. 30, 1843-1850 (2004).
    • (2004) J. Cataract Refract. Surg. , vol.30 , pp. 1843-1850
    • Baikoff, G.1    Lutun, E.2    Ferraz, C.3    Wei, J.4
  • 8
    • 33646434247 scopus 로고    scopus 로고
    • Photoacoustic imaging in biomedicine
    • Xu, M. and Wang, L.V., "Photoacoustic imaging in biomedicine," Rev. Sci. Instr. 77, 041101-1-21 (2006).
    • (2006) Rev. Sci. Instr. , vol.77
    • Xu, M.1    Wang, L.V.2
  • 9
    • 0028013110 scopus 로고
    • Photoacoustic ultrasound
    • Kruger, R.A., "Photoacoustic ultrasound," Med. Phys. 2, 127-131 (1994).
    • (1994) Med. Phys. , vol.2 , pp. 127-131
    • Kruger, R.A.1
  • 10
    • 33744687561 scopus 로고
    • Laser based optoacoustic imaging in biological tissues
    • Oraevsky, A.A., Jacques, S.L., Esenaliev, R.O. and Tittel, F.K., "Laser based optoacoustic imaging in biological tissues," Proc. SPIE, 2134A, 122-128 (1994).
    • (1994) Proc. SPIE , vol.2134 A , pp. 122-128
    • Oraevsky, A.A.1    Jacques, S.L.2    Esenaliev, R.O.3    Tittel, F.K.4
  • 11
    • 0029076401 scopus 로고
    • Optical properties of ocular fundus tissues - An in vitro study using the double-integrating-sphere technique and inverse Monte Carlo simulation
    • Hammer, M., Roggan, A., Schweitzer, D. and Muller, G., "Optical properties of ocular fundus tissues - an in vitro study using the double-integrating-sphere technique and inverse Monte Carlo simulation," Phys. Med. Biol. 40, 963-978 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 963-978
    • Hammer, M.1    Roggan, A.2    Schweitzer, D.3    Muller, G.4
  • 12
    • 34147115028 scopus 로고    scopus 로고
    • In-vivo diffusing-wave-spectroscopy measurements of the ocular fundus
    • DOI 10.1364/OE.15.004030
    • Rovati, L., Cattini, S., Zambelli, N., Viola, F. and Staurenghi, G.," In-vivo diffusing-wave-spectroscopy measurements of the ocular fundus." Opt. Expr., 15, 4030-4038 (2007). (Pubitemid 46557566)
    • (2007) Optics Express , vol.15 , Issue.7 , pp. 4030-4038
    • Rovati, L.1    Cattini, S.2    Zambelli, N.3    Viola, F.4    Staurenghi, G.5
  • 14
    • 0023865632 scopus 로고
    • 3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation
    • DOI 10.1016/0005-2728(88)90069-2
    • Wray, S., Cope, M., Delpy, D.T., Wyatt, J.S. and Reynolds, E.O.R., "Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation," Biochim. Biophys. Acta, 933, 184-192 (1988). (Pubitemid 18086628)
    • (1988) Biochimica et Biophysica Acta - Bioenergetics , vol.933 , Issue.1 , pp. 184-192
    • Wray, S.1    Cope, M.2    Delpy, D.T.3    Wyatt, J.S.4    Reynolds, E.O.R.5
  • 17
    • 56249090030 scopus 로고    scopus 로고
    • Prospects for gold nanorods particles in diagnostic and therapeutic applications
    • Pissuwan, D., Valenzuela, S.M. and Cortie, M.B., "Prospects for gold nanorods particles in diagnostic and therapeutic applications," Biotech. Gen. Eng. Rev., 25, 93-112 (2008).
    • (2008) Biotech. Gen. Eng. Rev. , vol.25 , pp. 93-112
    • Pissuwan, D.1    Valenzuela, S.M.2    Cortie, M.B.3
  • 18
    • 0345977867 scopus 로고
    • Large clusters and colloid metals in the embryonic state
    • Schmidt, G., "Large clusters and colloid metals in the embryonic state," Chem. Rev., 92, 1709-1727 (1992).
    • (1992) Chem. Rev. , vol.92 , pp. 1709-1727
    • Schmidt, G.1
  • 19
    • 0031213466 scopus 로고    scopus 로고
    • Gold nanorods: Electrochemical synthesis and optical properties
    • Yu, Y.Y., Chang, S.S., Lee, C.L. and Wang, C.R.C., "Gold nanorods: electrochemical synthesis and optical properties," J. Phys. Chem. B, 101, 6661-6664 (1997).
    • (1997) J. Phys. Chem. B , vol.101 , pp. 6661-6664
    • Yu, Y.Y.1    Chang, S.S.2    Lee, C.L.3    Wang, C.R.C.4
  • 20
    • 0000547095 scopus 로고    scopus 로고
    • Simulation of the optical absorption spectra of gold nanorods as a function of their aspect ratio and the effect of the medium dielectric constant
    • Link, S., Mohamed, M.B. and El-Sayed, M.A., "Simulation of the optical absorption spectra of gold nanorods as a function of their aspect ratio and the effect of the medium dielectric constant," J. Phys. Chem. B, 103, 3073-3077 (1999). (Pubitemid 129702441)
    • (1999) Journal of Physical Chemistry B , vol.103 , Issue.16 , pp. 3073-3077
    • Link, S.1    Mohamed, M.B.2    El-Sayed, M.A.3
  • 22
    • 0030667010 scopus 로고    scopus 로고
    • Statistical framework for ultrasonic spectral parameter imaging
    • DOI 10.1016/S0301-5629(97)00200-7, PII S0301562997002007
    • Lizzi, F.L., Astor, M., Feleppa, E.J., Shao, M. and Kalisz, A. "Statistical framework for ultrasonic spectral parameter imaging," Ultra. Med. Biol., 23, 1371-1382 (1997). (Pubitemid 27506339)
    • (1997) Ultrasound in Medicine and Biology , vol.23 , Issue.9 , pp. 1371-1382
    • Lizzi, F.L.1    Astor, M.2    Feleppa, E.J.3    Shao, M.4    Kalisz, A.5
  • 23
    • 33745128349 scopus 로고    scopus 로고
    • Spectral attenuation of the mouse, rat, pig and human lenses from wavelengths 360 nm to 1020 nm
    • DOI 10.1016/j.exer.2006.02.013, PII S0014483506001825
    • Lei, B. and Yao, G., "Spectral attenuation of the mouse, rat, pig and human lenses from wavelengths 360 nm to 1020 nm," Exp. Eye Res., 83:610-614 (2006). (Pubitemid 43902782)
    • (2006) Experimental Eye Research , vol.83 , Issue.3 , pp. 610-614
    • Lei, B.1    Yao, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.